Accuracy of three electronic apex locators in the presence of different irrigating solutions

Detalhes bibliográficos
Autor(a) principal: Carvalho,Ana Laura Pion
Data de Publicação: 2010
Outros Autores: Moura-Netto,Cacio, Moura,Abilio Albuquerque Maranhão de, Marques,Márcia Martins, Davidowicz,Harry
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000400004
Resumo: The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p &gt; 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.
id SBPQO-1_d4064728e0a9b9fa215c07d5f8d85954
oai_identifier_str oai:scielo:S1806-83242010000400004
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Accuracy of three electronic apex locators in the presence of different irrigating solutionsDental InstrumentsOdontometryRoot Canal TherapyEndodonticsThe present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p &gt; 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2010-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000400004Brazilian Oral Research v.24 n.4 2010reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242010000400004info:eu-repo/semantics/openAccessCarvalho,Ana Laura PionMoura-Netto,CacioMoura,Abilio Albuquerque Maranhão deMarques,Márcia MartinsDavidowicz,Harryeng2010-12-16T00:00:00Zoai:scielo:S1806-83242010000400004Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2010-12-16T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Accuracy of three electronic apex locators in the presence of different irrigating solutions
title Accuracy of three electronic apex locators in the presence of different irrigating solutions
spellingShingle Accuracy of three electronic apex locators in the presence of different irrigating solutions
Carvalho,Ana Laura Pion
Dental Instruments
Odontometry
Root Canal Therapy
Endodontics
title_short Accuracy of three electronic apex locators in the presence of different irrigating solutions
title_full Accuracy of three electronic apex locators in the presence of different irrigating solutions
title_fullStr Accuracy of three electronic apex locators in the presence of different irrigating solutions
title_full_unstemmed Accuracy of three electronic apex locators in the presence of different irrigating solutions
title_sort Accuracy of three electronic apex locators in the presence of different irrigating solutions
author Carvalho,Ana Laura Pion
author_facet Carvalho,Ana Laura Pion
Moura-Netto,Cacio
Moura,Abilio Albuquerque Maranhão de
Marques,Márcia Martins
Davidowicz,Harry
author_role author
author2 Moura-Netto,Cacio
Moura,Abilio Albuquerque Maranhão de
Marques,Márcia Martins
Davidowicz,Harry
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Carvalho,Ana Laura Pion
Moura-Netto,Cacio
Moura,Abilio Albuquerque Maranhão de
Marques,Márcia Martins
Davidowicz,Harry
dc.subject.por.fl_str_mv Dental Instruments
Odontometry
Root Canal Therapy
Endodontics
topic Dental Instruments
Odontometry
Root Canal Therapy
Endodontics
description The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p &gt; 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.
publishDate 2010
dc.date.none.fl_str_mv 2010-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000400004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242010000400004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242010000400004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.24 n.4 2010
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318322085265408