Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Pneumologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206 |
Resumo: | ABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP. |
id |
SBPT-1_493658831f3cf4b865438510ad478969 |
---|---|
oai_identifier_str |
oai:scielo:S1806-37132020000300206 |
network_acronym_str |
SBPT-1 |
network_name_str |
Jornal Brasileiro de Pneumologia (Online) |
repository_id_str |
|
spelling |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressureSleep apnea, obstructiveReproducibility of resultsExercise testExercise toleranceABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP.Sociedade Brasileira de Pneumologia e Tisiologia2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206Jornal Brasileiro de Pneumologia v.46 n.3 2020reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.36416/1806-3756/e20180422info:eu-repo/semantics/openAccessMagalhães,Matheus Gustavo SilvaTeixeira,Juliana BaptistaSantos,Ana Maria BezerraClímaco,Danielle Cristina SilvaSilva,Thayse Neves SantosLima,Anna Myrna Jaguaribe deeng2020-04-15T00:00:00Zoai:scielo:S1806-37132020000300206Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2020-04-15T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false |
dc.title.none.fl_str_mv |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
title |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
spellingShingle |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure Magalhães,Matheus Gustavo Silva Sleep apnea, obstructive Reproducibility of results Exercise test Exercise tolerance |
title_short |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
title_full |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
title_fullStr |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
title_full_unstemmed |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
title_sort |
Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure |
author |
Magalhães,Matheus Gustavo Silva |
author_facet |
Magalhães,Matheus Gustavo Silva Teixeira,Juliana Baptista Santos,Ana Maria Bezerra Clímaco,Danielle Cristina Silva Silva,Thayse Neves Santos Lima,Anna Myrna Jaguaribe de |
author_role |
author |
author2 |
Teixeira,Juliana Baptista Santos,Ana Maria Bezerra Clímaco,Danielle Cristina Silva Silva,Thayse Neves Santos Lima,Anna Myrna Jaguaribe de |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Magalhães,Matheus Gustavo Silva Teixeira,Juliana Baptista Santos,Ana Maria Bezerra Clímaco,Danielle Cristina Silva Silva,Thayse Neves Santos Lima,Anna Myrna Jaguaribe de |
dc.subject.por.fl_str_mv |
Sleep apnea, obstructive Reproducibility of results Exercise test Exercise tolerance |
topic |
Sleep apnea, obstructive Reproducibility of results Exercise test Exercise tolerance |
description |
ABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.36416/1806-3756/e20180422 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Pneumologia v.46 n.3 2020 reponame:Jornal Brasileiro de Pneumologia (Online) instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) instacron:SBPT |
instname_str |
Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
instacron_str |
SBPT |
institution |
SBPT |
reponame_str |
Jornal Brasileiro de Pneumologia (Online) |
collection |
Jornal Brasileiro de Pneumologia (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
repository.mail.fl_str_mv |
||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br |
_version_ |
1750318347764891648 |