Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure

Detalhes bibliográficos
Autor(a) principal: Magalhães,Matheus Gustavo Silva
Data de Publicação: 2020
Outros Autores: Teixeira,Juliana Baptista, Santos,Ana Maria Bezerra, Clímaco,Danielle Cristina Silva, Silva,Thayse Neves Santos, Lima,Anna Myrna Jaguaribe de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Pneumologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206
Resumo: ABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP.
id SBPT-1_493658831f3cf4b865438510ad478969
oai_identifier_str oai:scielo:S1806-37132020000300206
network_acronym_str SBPT-1
network_name_str Jornal Brasileiro de Pneumologia (Online)
repository_id_str
spelling Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressureSleep apnea, obstructiveReproducibility of resultsExercise testExercise toleranceABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP.Sociedade Brasileira de Pneumologia e Tisiologia2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206Jornal Brasileiro de Pneumologia v.46 n.3 2020reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.36416/1806-3756/e20180422info:eu-repo/semantics/openAccessMagalhães,Matheus Gustavo SilvaTeixeira,Juliana BaptistaSantos,Ana Maria BezerraClímaco,Danielle Cristina SilvaSilva,Thayse Neves SantosLima,Anna Myrna Jaguaribe deeng2020-04-15T00:00:00Zoai:scielo:S1806-37132020000300206Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2020-04-15T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false
dc.title.none.fl_str_mv Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
title Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
spellingShingle Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
Magalhães,Matheus Gustavo Silva
Sleep apnea, obstructive
Reproducibility of results
Exercise test
Exercise tolerance
title_short Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
title_full Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
title_fullStr Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
title_full_unstemmed Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
title_sort Construct validity and reproducibility of the six-minute step test in subjects with obstructive sleep apnea treated with continuous positive airway pressure
author Magalhães,Matheus Gustavo Silva
author_facet Magalhães,Matheus Gustavo Silva
Teixeira,Juliana Baptista
Santos,Ana Maria Bezerra
Clímaco,Danielle Cristina Silva
Silva,Thayse Neves Santos
Lima,Anna Myrna Jaguaribe de
author_role author
author2 Teixeira,Juliana Baptista
Santos,Ana Maria Bezerra
Clímaco,Danielle Cristina Silva
Silva,Thayse Neves Santos
Lima,Anna Myrna Jaguaribe de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Magalhães,Matheus Gustavo Silva
Teixeira,Juliana Baptista
Santos,Ana Maria Bezerra
Clímaco,Danielle Cristina Silva
Silva,Thayse Neves Santos
Lima,Anna Myrna Jaguaribe de
dc.subject.por.fl_str_mv Sleep apnea, obstructive
Reproducibility of results
Exercise test
Exercise tolerance
topic Sleep apnea, obstructive
Reproducibility of results
Exercise test
Exercise tolerance
description ABSTRACT Objective: To evaluate the construct validity and reproducibility of the six-minute step test (6MST) in individuals with obstructive sleep apnea (OSA) treated with continuous positive airway pressure (CPAP). Methods: We evaluated 48 volunteers diagnosed with OSA and treated with CPAP for at least two months. The volunteers underwent the six-minute walk test (6MWT) and the 6MST, in random order and on different days, with an interval of, at most, seven days between the two tests. Results: A moderate positive correlation was found between the distance walked on the 6MWT and the number of steps climbed on the 6MST (r = 0.520; p < 0.001). There was no significant difference between the two 6MSTs in terms of the number of steps climbed (121.7 ± 27.1 vs. 123.6 ± 26.7). Reproducibility for performance on the 6MST and for cardiovascular variables was considered excellent (intraclass correlation coefficient > 0.8). Regarding cardiovascular responses, the 6MST produced higher values than did the 6MWT for HR at six minutes, percent predicted maximum HR, and leg fatigue at six minutes, as well as for systolic blood pressure at six minutes and at one minute of recovery. Conclusions: The 6MST is valid and reproducible, producing greater cardiovascular stress than does the 6MWT. However, the 6MST is also characterized as a submaximal test for the assessment of exercise tolerance in individuals with OSA treated with CPAP.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132020000300206
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.36416/1806-3756/e20180422
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
dc.source.none.fl_str_mv Jornal Brasileiro de Pneumologia v.46 n.3 2020
reponame:Jornal Brasileiro de Pneumologia (Online)
instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron:SBPT
instname_str Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron_str SBPT
institution SBPT
reponame_str Jornal Brasileiro de Pneumologia (Online)
collection Jornal Brasileiro de Pneumologia (Online)
repository.name.fl_str_mv Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
repository.mail.fl_str_mv ||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br
_version_ 1750318347764891648