Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001202291 |
Resumo: | Dispersive liquid-liquid microextraction (DLLME) and spectrofluorimetry, coupled with chemometrics methods, are proposed in this work for the pre-concentration and determination of ofloxacin concentration in spiked human urine. Chloroform and acetonitrile were selected as the extraction and dispersive solvents by the one-variable-at-a-time process. The Box-Behnken design was used to optimize the other variables, including the volume of extraction and dispersion solvents, solution pH, and ionic strength. A linear calibration curve was obtained in the 5.0-120.0 ng mL-1 range under optimal conditions with a detection limit of 1.61 ng mL-1 and correlation coefficient of 0.9948. A relative standard deviation (RSD) of 1.13% was obtained for seven consecutive replicates. Parallel factor analysis (PARAFAC) and partial least square (PLS) modeling were applied for the multivariate calibration of the spectrofluorimetric data. To pre-process the data matrices and predict the model results, the orthogonal signal correction (OSC) was used, and the analysis results were statistically compared. The methods accuracy values for ofloxacin determination, evaluated by the root mean square errors of prediction (RMSEP) and relative standard error of prediction (RSEP), were 0.82 and 1.12 using OSC-PLS, and 0.31 and 0.42 using OSC-PARAFAC models, respectively. Ofloxacin can be reliably determined in human urine samples through the proposed procedure, according to the results. |
id |
SBQ-2_0705cadc7b5899b220f733a3bce94f04 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532017001202291 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetryofloxacindispersive liquid-liquid microextractionspectrofluorimetryBox-Behnken designOSC-PARAFACDispersive liquid-liquid microextraction (DLLME) and spectrofluorimetry, coupled with chemometrics methods, are proposed in this work for the pre-concentration and determination of ofloxacin concentration in spiked human urine. Chloroform and acetonitrile were selected as the extraction and dispersive solvents by the one-variable-at-a-time process. The Box-Behnken design was used to optimize the other variables, including the volume of extraction and dispersion solvents, solution pH, and ionic strength. A linear calibration curve was obtained in the 5.0-120.0 ng mL-1 range under optimal conditions with a detection limit of 1.61 ng mL-1 and correlation coefficient of 0.9948. A relative standard deviation (RSD) of 1.13% was obtained for seven consecutive replicates. Parallel factor analysis (PARAFAC) and partial least square (PLS) modeling were applied for the multivariate calibration of the spectrofluorimetric data. To pre-process the data matrices and predict the model results, the orthogonal signal correction (OSC) was used, and the analysis results were statistically compared. The methods accuracy values for ofloxacin determination, evaluated by the root mean square errors of prediction (RMSEP) and relative standard error of prediction (RSEP), were 0.82 and 1.12 using OSC-PLS, and 0.31 and 0.42 using OSC-PARAFAC models, respectively. Ofloxacin can be reliably determined in human urine samples through the proposed procedure, according to the results.Sociedade Brasileira de Química2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001202291Journal of the Brazilian Chemical Society v.28 n.12 2017reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20170080info:eu-repo/semantics/openAccessAssadian,FarahNiazi,Alieng2017-11-06T00:00:00Zoai:scielo:S0103-50532017001202291Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2017-11-06T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
title |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
spellingShingle |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry Assadian,Farah ofloxacin dispersive liquid-liquid microextraction spectrofluorimetry Box-Behnken design OSC-PARAFAC |
title_short |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
title_full |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
title_fullStr |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
title_full_unstemmed |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
title_sort |
Application of Response Surface Modeling and Chemometrics Methods for the Determination of Ofloxacin in Human Urine Using Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry |
author |
Assadian,Farah |
author_facet |
Assadian,Farah Niazi,Ali |
author_role |
author |
author2 |
Niazi,Ali |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Assadian,Farah Niazi,Ali |
dc.subject.por.fl_str_mv |
ofloxacin dispersive liquid-liquid microextraction spectrofluorimetry Box-Behnken design OSC-PARAFAC |
topic |
ofloxacin dispersive liquid-liquid microextraction spectrofluorimetry Box-Behnken design OSC-PARAFAC |
description |
Dispersive liquid-liquid microextraction (DLLME) and spectrofluorimetry, coupled with chemometrics methods, are proposed in this work for the pre-concentration and determination of ofloxacin concentration in spiked human urine. Chloroform and acetonitrile were selected as the extraction and dispersive solvents by the one-variable-at-a-time process. The Box-Behnken design was used to optimize the other variables, including the volume of extraction and dispersion solvents, solution pH, and ionic strength. A linear calibration curve was obtained in the 5.0-120.0 ng mL-1 range under optimal conditions with a detection limit of 1.61 ng mL-1 and correlation coefficient of 0.9948. A relative standard deviation (RSD) of 1.13% was obtained for seven consecutive replicates. Parallel factor analysis (PARAFAC) and partial least square (PLS) modeling were applied for the multivariate calibration of the spectrofluorimetric data. To pre-process the data matrices and predict the model results, the orthogonal signal correction (OSC) was used, and the analysis results were statistically compared. The methods accuracy values for ofloxacin determination, evaluated by the root mean square errors of prediction (RMSEP) and relative standard error of prediction (RSEP), were 0.82 and 1.12 using OSC-PLS, and 0.31 and 0.42 using OSC-PARAFAC models, respectively. Ofloxacin can be reliably determined in human urine samples through the proposed procedure, according to the results. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001202291 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001202291 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0103-5053.20170080 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.28 n.12 2017 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318180045160448 |