Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000901879 |
Resumo: | Bismuth was evaluated as internal standard for Pb determinations and showed usefulness to minimize variations due to changes in the experimental conditions of the inductively coupled plasma optical emission spectrometry (ICP OES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Thirty four samples were analyzed and the Pb contents obtained by ICP-MS and ETV-ICP-MS were in agreement at 95% confidence level. Plant, biological tissue and soil reference materials were also analyzed and the results were close to certified values upon the use of the internal standard. Recoveries for Pb spikes (ICP OES: 95-110%; ICP-MS: 95-106%; ETV-ICP-MS: 92-119%) were better than those obtained with external calibration (ICP OES: 56-91%; ICP-MS: 36-136%; ETV‑ICP-MS: 5-123%). The relative standard deviations (n = 12) was improved from 1-9% to 0.2-6% (ICP OES), from 0.5-11% to 0.1-7% (ICP-MS) and from 0.4-7% to 0.1-4% (ETV‑ICP‑MS) by using external and internal standard calibrations, respectively. |
id |
SBQ-2_6612193d9da2008aa0d4fdb82cb5f2c8 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532015000901879 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniqueslead determinationBi internal standardICP OESICP-MSETV-ICP-MSBismuth was evaluated as internal standard for Pb determinations and showed usefulness to minimize variations due to changes in the experimental conditions of the inductively coupled plasma optical emission spectrometry (ICP OES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Thirty four samples were analyzed and the Pb contents obtained by ICP-MS and ETV-ICP-MS were in agreement at 95% confidence level. Plant, biological tissue and soil reference materials were also analyzed and the results were close to certified values upon the use of the internal standard. Recoveries for Pb spikes (ICP OES: 95-110%; ICP-MS: 95-106%; ETV-ICP-MS: 92-119%) were better than those obtained with external calibration (ICP OES: 56-91%; ICP-MS: 36-136%; ETV‑ICP-MS: 5-123%). The relative standard deviations (n = 12) was improved from 1-9% to 0.2-6% (ICP OES), from 0.5-11% to 0.1-7% (ICP-MS) and from 0.4-7% to 0.1-4% (ETV‑ICP‑MS) by using external and internal standard calibrations, respectively.Sociedade Brasileira de Química2015-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000901879Journal of the Brazilian Chemical Society v.26 n.9 2015reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20150165info:eu-repo/semantics/openAccessBechlin,Marcos A.Ferreira,Edilene C.Gomes Neto,José A.Ramos,Juliano C.Borges,Daniel L. G.eng2015-09-11T00:00:00Zoai:scielo:S0103-50532015000901879Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2015-09-11T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
title |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
spellingShingle |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques Bechlin,Marcos A. lead determination Bi internal standard ICP OES ICP-MS ETV-ICP-MS |
title_short |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
title_full |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
title_fullStr |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
title_full_unstemmed |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
title_sort |
Contributions on the Use of Bismuth as Internal Standard for Lead Determinations Using ICP-Based Techniques |
author |
Bechlin,Marcos A. |
author_facet |
Bechlin,Marcos A. Ferreira,Edilene C. Gomes Neto,José A. Ramos,Juliano C. Borges,Daniel L. G. |
author_role |
author |
author2 |
Ferreira,Edilene C. Gomes Neto,José A. Ramos,Juliano C. Borges,Daniel L. G. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Bechlin,Marcos A. Ferreira,Edilene C. Gomes Neto,José A. Ramos,Juliano C. Borges,Daniel L. G. |
dc.subject.por.fl_str_mv |
lead determination Bi internal standard ICP OES ICP-MS ETV-ICP-MS |
topic |
lead determination Bi internal standard ICP OES ICP-MS ETV-ICP-MS |
description |
Bismuth was evaluated as internal standard for Pb determinations and showed usefulness to minimize variations due to changes in the experimental conditions of the inductively coupled plasma optical emission spectrometry (ICP OES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Thirty four samples were analyzed and the Pb contents obtained by ICP-MS and ETV-ICP-MS were in agreement at 95% confidence level. Plant, biological tissue and soil reference materials were also analyzed and the results were close to certified values upon the use of the internal standard. Recoveries for Pb spikes (ICP OES: 95-110%; ICP-MS: 95-106%; ETV-ICP-MS: 92-119%) were better than those obtained with external calibration (ICP OES: 56-91%; ICP-MS: 36-136%; ETV‑ICP-MS: 5-123%). The relative standard deviations (n = 12) was improved from 1-9% to 0.2-6% (ICP OES), from 0.5-11% to 0.1-7% (ICP-MS) and from 0.4-7% to 0.1-4% (ETV‑ICP‑MS) by using external and internal standard calibrations, respectively. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000901879 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000901879 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20150165 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.26 n.9 2015 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318177486635008 |