Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000500016 |
Resumo: | A method for the determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry (CVG-ETV-ICP-MS) using isotope dilution calibration after acid digestion is proposed. The samples were digested with aqua regia in a microwave oven. The isotope ratios used for quantification were: 201Hg/202Hg and 77Se/82Se. A NaBH4 solution stabilized with NaOH was used as reducing agent. The retention and vaporization temperatures in the graphite tube were 150 and 2000 ºC, respectively. Six certified biological materials were analyzed and the obtained concentrations were in good agreement with the certified values according to the t-test for a confidence level of 95%. The detection limits in the sample were 0.7 and 3 ng g-1, for Hg and Se respectively. The method is precise, accurate and adequate for the analysis of biological samples in routine and demonstrates the feasibility of using isotope dilution for the proposed system. |
id |
SBQ-2_672b287bd7505933d6bb05835f72b1ed |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532006000500016 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regiachemical vapor generationbiological samplesmicrowave digestionretention on the graphite tubeisotopic dilution calibrationETV-ICP-MSA method for the determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry (CVG-ETV-ICP-MS) using isotope dilution calibration after acid digestion is proposed. The samples were digested with aqua regia in a microwave oven. The isotope ratios used for quantification were: 201Hg/202Hg and 77Se/82Se. A NaBH4 solution stabilized with NaOH was used as reducing agent. The retention and vaporization temperatures in the graphite tube were 150 and 2000 ºC, respectively. Six certified biological materials were analyzed and the obtained concentrations were in good agreement with the certified values according to the t-test for a confidence level of 95%. The detection limits in the sample were 0.7 and 3 ng g-1, for Hg and Se respectively. The method is precise, accurate and adequate for the analysis of biological samples in routine and demonstrates the feasibility of using isotope dilution for the proposed system.Sociedade Brasileira de Química2006-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000500016Journal of the Brazilian Chemical Society v.17 n.5 2006reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532006000500016info:eu-repo/semantics/openAccessVieira,Mariana A.Ribeiro,Anderson S.Dias,Lúcia F.Curtius,Adilson J.eng2006-12-01T00:00:00Zoai:scielo:S0103-50532006000500016Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2006-12-01T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
title |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
spellingShingle |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia Vieira,Mariana A. chemical vapor generation biological samples microwave digestion retention on the graphite tube isotopic dilution calibration ETV-ICP-MS |
title_short |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
title_full |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
title_fullStr |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
title_full_unstemmed |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
title_sort |
Determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry using isotope dilution calibration after microwave-assisted digestion with Aqua Regia |
author |
Vieira,Mariana A. |
author_facet |
Vieira,Mariana A. Ribeiro,Anderson S. Dias,Lúcia F. Curtius,Adilson J. |
author_role |
author |
author2 |
Ribeiro,Anderson S. Dias,Lúcia F. Curtius,Adilson J. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Vieira,Mariana A. Ribeiro,Anderson S. Dias,Lúcia F. Curtius,Adilson J. |
dc.subject.por.fl_str_mv |
chemical vapor generation biological samples microwave digestion retention on the graphite tube isotopic dilution calibration ETV-ICP-MS |
topic |
chemical vapor generation biological samples microwave digestion retention on the graphite tube isotopic dilution calibration ETV-ICP-MS |
description |
A method for the determination of Hg and Se in biological materials by chemical vapor generation electrothermal vaporization inductively coupled plasma mass spectrometry (CVG-ETV-ICP-MS) using isotope dilution calibration after acid digestion is proposed. The samples were digested with aqua regia in a microwave oven. The isotope ratios used for quantification were: 201Hg/202Hg and 77Se/82Se. A NaBH4 solution stabilized with NaOH was used as reducing agent. The retention and vaporization temperatures in the graphite tube were 150 and 2000 ºC, respectively. Six certified biological materials were analyzed and the obtained concentrations were in good agreement with the certified values according to the t-test for a confidence level of 95%. The detection limits in the sample were 0.7 and 3 ng g-1, for Hg and Se respectively. The method is precise, accurate and adequate for the analysis of biological samples in routine and demonstrates the feasibility of using isotope dilution for the proposed system. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000500016 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000500016 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532006000500016 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.17 n.5 2006 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318167352147968 |