New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001001953 |
Resumo: | This paper presents a study involving the development of a new mini polytetrafluoroethylene (PTFE) vessel project for biological sample preparation in micro scale in closed system with microwave radiation for subsequent determination of Cd, K, Mg and Na by atomic spectrometry techniques. All experiments were carried out in micro quantities of samples (up to 20 mg) and reagents (300 µL of HNO3) for 5 min at 350 W. Certified reference materials of biological samples (bovine muscle and liver) were used to evaluate the accuracy of the proposed system and the results obtained were in agreement with the certified value at 95% of confidence (t -test). Relative standard deviations (RSD) were lower than 8.0% for all elements. The proposed method is not only easy and fast, but it is also based on the use of an inexpensive system for sample digestion. |
id |
SBQ-2_87f40e6cd8a7c7d359104d4199194e98 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532017001001953 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Samplemicro digestionmini PTFE vesselsbiological samplesatomic spectrometry techniquesThis paper presents a study involving the development of a new mini polytetrafluoroethylene (PTFE) vessel project for biological sample preparation in micro scale in closed system with microwave radiation for subsequent determination of Cd, K, Mg and Na by atomic spectrometry techniques. All experiments were carried out in micro quantities of samples (up to 20 mg) and reagents (300 µL of HNO3) for 5 min at 350 W. Certified reference materials of biological samples (bovine muscle and liver) were used to evaluate the accuracy of the proposed system and the results obtained were in agreement with the certified value at 95% of confidence (t -test). Relative standard deviations (RSD) were lower than 8.0% for all elements. The proposed method is not only easy and fast, but it is also based on the use of an inexpensive system for sample digestion.Sociedade Brasileira de Química2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001001953Journal of the Brazilian Chemical Society v.28 n.10 2017reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20170037info:eu-repo/semantics/openAccessOliz,Camila M.Souza,Alexander O.Pereira,Camila C.Oliveira,Richard M.Medina,Aline L.Vieira,Mariana A.Ribeiro,Anderson S.Nunes,Adriane M.eng2017-09-22T00:00:00Zoai:scielo:S0103-50532017001001953Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2017-09-22T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
title |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
spellingShingle |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample Oliz,Camila M. micro digestion mini PTFE vessels biological samples atomic spectrometry techniques |
title_short |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
title_full |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
title_fullStr |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
title_full_unstemmed |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
title_sort |
New Design of Mini PTFE Vessels for Sample Preparation in Micro Scale: Determination of Cd, K, Mg and Na in Biological Sample |
author |
Oliz,Camila M. |
author_facet |
Oliz,Camila M. Souza,Alexander O. Pereira,Camila C. Oliveira,Richard M. Medina,Aline L. Vieira,Mariana A. Ribeiro,Anderson S. Nunes,Adriane M. |
author_role |
author |
author2 |
Souza,Alexander O. Pereira,Camila C. Oliveira,Richard M. Medina,Aline L. Vieira,Mariana A. Ribeiro,Anderson S. Nunes,Adriane M. |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Oliz,Camila M. Souza,Alexander O. Pereira,Camila C. Oliveira,Richard M. Medina,Aline L. Vieira,Mariana A. Ribeiro,Anderson S. Nunes,Adriane M. |
dc.subject.por.fl_str_mv |
micro digestion mini PTFE vessels biological samples atomic spectrometry techniques |
topic |
micro digestion mini PTFE vessels biological samples atomic spectrometry techniques |
description |
This paper presents a study involving the development of a new mini polytetrafluoroethylene (PTFE) vessel project for biological sample preparation in micro scale in closed system with microwave radiation for subsequent determination of Cd, K, Mg and Na by atomic spectrometry techniques. All experiments were carried out in micro quantities of samples (up to 20 mg) and reagents (300 µL of HNO3) for 5 min at 350 W. Certified reference materials of biological samples (bovine muscle and liver) were used to evaluate the accuracy of the proposed system and the results obtained were in agreement with the certified value at 95% of confidence (t -test). Relative standard deviations (RSD) were lower than 8.0% for all elements. The proposed method is not only easy and fast, but it is also based on the use of an inexpensive system for sample digestion. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001001953 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017001001953 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0103-5053.20170037 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.28 n.10 2017 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318179988537344 |