Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532016000500919 |
Resumo: | The aim of this study was to evaluate the performance of a reflux system adapted in the digestion tubes in sample preparation of xanthan gum for subsequent determination of Ca, Cu, K, Mg, Na and Zn by using spectrometric techniques. Through the proposed method, the samples were digested with HNO3 for 3 h in a digester block at 220 °C. The accuracy of the method was evaluated by comparing the results with another sample preparation method and by using recovery tests, which results vary between 83 and 103%. The efficiency of digestion was assessed and significant results were verified through residual carbon values, which were five times lower compared to conventional acid digestion in open system, with use of HNO3 and HClO4. The proposed methodology is a simple and accurate analytical strategy, which does not require the use of special equipment, neither a mixture of strong oxidizing acid in the sample preparation. |
id |
SBQ-2_f1fc47ef78cfb35a14e1976f067d8f07 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532016000500919 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniquesxanthan gumsample preparationreflux systematomic spectrometry techniquesThe aim of this study was to evaluate the performance of a reflux system adapted in the digestion tubes in sample preparation of xanthan gum for subsequent determination of Ca, Cu, K, Mg, Na and Zn by using spectrometric techniques. Through the proposed method, the samples were digested with HNO3 for 3 h in a digester block at 220 °C. The accuracy of the method was evaluated by comparing the results with another sample preparation method and by using recovery tests, which results vary between 83 and 103%. The efficiency of digestion was assessed and significant results were verified through residual carbon values, which were five times lower compared to conventional acid digestion in open system, with use of HNO3 and HClO4. The proposed methodology is a simple and accurate analytical strategy, which does not require the use of special equipment, neither a mixture of strong oxidizing acid in the sample preparation.Sociedade Brasileira de Química2016-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532016000500919Journal of the Brazilian Chemical Society v.27 n.5 2016reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20150346info:eu-repo/semantics/openAccessRosa,Michele B. daOreste,Eliézer Q.Bönemann,Daísa H.Rodrigues,Amanda A.Vendruscolo,Claire T.Moreira,Angelita S.Ribeiro,Anderson S.Nunes,Adriane M.eng2016-05-18T00:00:00Zoai:scielo:S0103-50532016000500919Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2016-05-18T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
title |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
spellingShingle |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques Rosa,Michele B. da xanthan gum sample preparation reflux system atomic spectrometry techniques |
title_short |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
title_full |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
title_fullStr |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
title_full_unstemmed |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
title_sort |
Evaluation of the Use of a Reflux System for Sample Preparation of Xanthan Gum and Subsequent Determination of Ca, Cu, K, Mg, Na and Zn by Atomic Spectrometry Techniques |
author |
Rosa,Michele B. da |
author_facet |
Rosa,Michele B. da Oreste,Eliézer Q. Bönemann,Daísa H. Rodrigues,Amanda A. Vendruscolo,Claire T. Moreira,Angelita S. Ribeiro,Anderson S. Nunes,Adriane M. |
author_role |
author |
author2 |
Oreste,Eliézer Q. Bönemann,Daísa H. Rodrigues,Amanda A. Vendruscolo,Claire T. Moreira,Angelita S. Ribeiro,Anderson S. Nunes,Adriane M. |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Rosa,Michele B. da Oreste,Eliézer Q. Bönemann,Daísa H. Rodrigues,Amanda A. Vendruscolo,Claire T. Moreira,Angelita S. Ribeiro,Anderson S. Nunes,Adriane M. |
dc.subject.por.fl_str_mv |
xanthan gum sample preparation reflux system atomic spectrometry techniques |
topic |
xanthan gum sample preparation reflux system atomic spectrometry techniques |
description |
The aim of this study was to evaluate the performance of a reflux system adapted in the digestion tubes in sample preparation of xanthan gum for subsequent determination of Ca, Cu, K, Mg, Na and Zn by using spectrometric techniques. Through the proposed method, the samples were digested with HNO3 for 3 h in a digester block at 220 °C. The accuracy of the method was evaluated by comparing the results with another sample preparation method and by using recovery tests, which results vary between 83 and 103%. The efficiency of digestion was assessed and significant results were verified through residual carbon values, which were five times lower compared to conventional acid digestion in open system, with use of HNO3 and HClO4. The proposed methodology is a simple and accurate analytical strategy, which does not require the use of special equipment, neither a mixture of strong oxidizing acid in the sample preparation. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-05-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532016000500919 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532016000500919 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20150346 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.27 n.5 2016 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318178332835840 |