A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000300024 |
Resumo: | Herein, the construction and performance characteristic of a polymeric membrane electrode based on ion-pair formation of salmon sperm ds-DNA-amiloride for quantification of amiloride is described. Salmon sperm ds-DNA-amiloride layer can be prepared easily as a coating layer on a Pt-wire electrode. This electrode has a good potentiometric response to amiloride. The influences of the membrane compositions on the potentiometric response of the electrode have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (m/m) of ds-DNA-amiloride as an ion pair (6.4%), polyvinyl chloride (PVC) matrix (62.9%), and 2-nitrophenyl octylether (NPOE) as an ion excluder (30.7%). The proposed electrode exhibits Nernstian response in the concentration range of 1.6 10-6 to 1.0 × 10-2 mol L-1 amiloride with a detection limit of 1.5 × 10-6 mol L-1 amiloride, performs satisfactorily with a fast response time of 5 s. Selectivity coefficients for amiloride relative to a numbers of potential interfering substances were investigated. The sensor was highly selective for amiloride over a large number of compounds. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of amiloride in real samples. |
id |
SBQ-2_b5f6974ba7598a7c678d568b3c1e7a11 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532010000300024 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urineamiloride determinationds-DNA modified electrodepotentiometryHerein, the construction and performance characteristic of a polymeric membrane electrode based on ion-pair formation of salmon sperm ds-DNA-amiloride for quantification of amiloride is described. Salmon sperm ds-DNA-amiloride layer can be prepared easily as a coating layer on a Pt-wire electrode. This electrode has a good potentiometric response to amiloride. The influences of the membrane compositions on the potentiometric response of the electrode have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (m/m) of ds-DNA-amiloride as an ion pair (6.4%), polyvinyl chloride (PVC) matrix (62.9%), and 2-nitrophenyl octylether (NPOE) as an ion excluder (30.7%). The proposed electrode exhibits Nernstian response in the concentration range of 1.6 10-6 to 1.0 × 10-2 mol L-1 amiloride with a detection limit of 1.5 × 10-6 mol L-1 amiloride, performs satisfactorily with a fast response time of 5 s. Selectivity coefficients for amiloride relative to a numbers of potential interfering substances were investigated. The sensor was highly selective for amiloride over a large number of compounds. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of amiloride in real samples.Sociedade Brasileira de Química2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000300024Journal of the Brazilian Chemical Society v.21 n.3 2010reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532010000300024info:eu-repo/semantics/openAccessAllafchian,AlirezaEnsafi,Ali Asghareng2010-05-03T00:00:00Zoai:scielo:S0103-50532010000300024Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2010-05-03T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
title |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
spellingShingle |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine Allafchian,Alireza amiloride determination ds-DNA modified electrode potentiometry |
title_short |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
title_full |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
title_fullStr |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
title_full_unstemmed |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
title_sort |
A DNA-based coated wire membrane sensor for selective determination of amiloride in pharmaceutical compounds, plasma and urine |
author |
Allafchian,Alireza |
author_facet |
Allafchian,Alireza Ensafi,Ali Asghar |
author_role |
author |
author2 |
Ensafi,Ali Asghar |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Allafchian,Alireza Ensafi,Ali Asghar |
dc.subject.por.fl_str_mv |
amiloride determination ds-DNA modified electrode potentiometry |
topic |
amiloride determination ds-DNA modified electrode potentiometry |
description |
Herein, the construction and performance characteristic of a polymeric membrane electrode based on ion-pair formation of salmon sperm ds-DNA-amiloride for quantification of amiloride is described. Salmon sperm ds-DNA-amiloride layer can be prepared easily as a coating layer on a Pt-wire electrode. This electrode has a good potentiometric response to amiloride. The influences of the membrane compositions on the potentiometric response of the electrode have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (m/m) of ds-DNA-amiloride as an ion pair (6.4%), polyvinyl chloride (PVC) matrix (62.9%), and 2-nitrophenyl octylether (NPOE) as an ion excluder (30.7%). The proposed electrode exhibits Nernstian response in the concentration range of 1.6 10-6 to 1.0 × 10-2 mol L-1 amiloride with a detection limit of 1.5 × 10-6 mol L-1 amiloride, performs satisfactorily with a fast response time of 5 s. Selectivity coefficients for amiloride relative to a numbers of potential interfering substances were investigated. The sensor was highly selective for amiloride over a large number of compounds. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of amiloride in real samples. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000300024 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000300024 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532010000300024 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.21 n.3 2010 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318170682425344 |