Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000601309 |
Resumo: | An automated method based on open-source hardware was created for the separation of porphyrins fractions from crude oil, an essential step for the quantification of V and Ni as metalloporphyrins. Preparative liquid chromatography was implemented with a reverse phase gradient from MeOH to toluene. The system allows three solvents and fractions changes by using quaternary valves connected to an Arduino microcontroller, programmed on the basis of the absorbance signal measured and its first derivative. Additionally, the method was applied to crude oils (Venezuelan National Institute of Standards and Technology (NIST) 8505 and from a marine reservoir). V and Ni were determined by inductively coupled plasma mass spectrometry (ICP-MS) and the V-porphyrin profile was determined by high performance liquid chromatography (HPLC)-ICP-MS. The concentrations of the metals grow in the last eluting toluene fractions, associated with asphaltenes. On the other hand, V-porphyrins in the first eluting MeOH fractions showed profiles of labile compounds, with a higher percentage in the Brazilian crude oil (4.9 mg L-1, corresponding to 18% of total V), in comparison to the one from the biodegraded NIST 8505 (59 mg L-1, corresponding to 7% of total V). The overall methodology has a good reproducibility and provides information on elements concentrations associated with porphyrin class compounds. |
id |
SBQ-2_e43c269dfc228e431be524823beeb2cb |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532019000601309 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrinsautomated separationV and Ni porphyrinsabsorbance derivativeICP-MSHPLC-ICP-MSopen-source scientific hardwareAn automated method based on open-source hardware was created for the separation of porphyrins fractions from crude oil, an essential step for the quantification of V and Ni as metalloporphyrins. Preparative liquid chromatography was implemented with a reverse phase gradient from MeOH to toluene. The system allows three solvents and fractions changes by using quaternary valves connected to an Arduino microcontroller, programmed on the basis of the absorbance signal measured and its first derivative. Additionally, the method was applied to crude oils (Venezuelan National Institute of Standards and Technology (NIST) 8505 and from a marine reservoir). V and Ni were determined by inductively coupled plasma mass spectrometry (ICP-MS) and the V-porphyrin profile was determined by high performance liquid chromatography (HPLC)-ICP-MS. The concentrations of the metals grow in the last eluting toluene fractions, associated with asphaltenes. On the other hand, V-porphyrins in the first eluting MeOH fractions showed profiles of labile compounds, with a higher percentage in the Brazilian crude oil (4.9 mg L-1, corresponding to 18% of total V), in comparison to the one from the biodegraded NIST 8505 (59 mg L-1, corresponding to 7% of total V). The overall methodology has a good reproducibility and provides information on elements concentrations associated with porphyrin class compounds.Sociedade Brasileira de Química2019-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000601309Journal of the Brazilian Chemical Society v.30 n.6 2019reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20190029info:eu-repo/semantics/openAccessSilva,Daniel M.Pereira,Álvaro J.Pierre,Tatiana D. Saint’Esteves,Pierre M.Rocha,Anderson A.Escalfoni Jr.,RainérioDuyck,Christianeeng2019-05-20T00:00:00Zoai:scielo:S0103-50532019000601309Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2019-05-20T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
title |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
spellingShingle |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins Silva,Daniel M. automated separation V and Ni porphyrins absorbance derivative ICP-MS HPLC-ICP-MS open-source scientific hardware |
title_short |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
title_full |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
title_fullStr |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
title_full_unstemmed |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
title_sort |
Automatized Separation of Fractions from Petroleum Based on Spectrophotometric Signal Derivative Using Open-Source Hardware for the Determination of Ni and V Linked to Porphyrins |
author |
Silva,Daniel M. |
author_facet |
Silva,Daniel M. Pereira,Álvaro J. Pierre,Tatiana D. Saint’ Esteves,Pierre M. Rocha,Anderson A. Escalfoni Jr.,Rainério Duyck,Christiane |
author_role |
author |
author2 |
Pereira,Álvaro J. Pierre,Tatiana D. Saint’ Esteves,Pierre M. Rocha,Anderson A. Escalfoni Jr.,Rainério Duyck,Christiane |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Silva,Daniel M. Pereira,Álvaro J. Pierre,Tatiana D. Saint’ Esteves,Pierre M. Rocha,Anderson A. Escalfoni Jr.,Rainério Duyck,Christiane |
dc.subject.por.fl_str_mv |
automated separation V and Ni porphyrins absorbance derivative ICP-MS HPLC-ICP-MS open-source scientific hardware |
topic |
automated separation V and Ni porphyrins absorbance derivative ICP-MS HPLC-ICP-MS open-source scientific hardware |
description |
An automated method based on open-source hardware was created for the separation of porphyrins fractions from crude oil, an essential step for the quantification of V and Ni as metalloporphyrins. Preparative liquid chromatography was implemented with a reverse phase gradient from MeOH to toluene. The system allows three solvents and fractions changes by using quaternary valves connected to an Arduino microcontroller, programmed on the basis of the absorbance signal measured and its first derivative. Additionally, the method was applied to crude oils (Venezuelan National Institute of Standards and Technology (NIST) 8505 and from a marine reservoir). V and Ni were determined by inductively coupled plasma mass spectrometry (ICP-MS) and the V-porphyrin profile was determined by high performance liquid chromatography (HPLC)-ICP-MS. The concentrations of the metals grow in the last eluting toluene fractions, associated with asphaltenes. On the other hand, V-porphyrins in the first eluting MeOH fractions showed profiles of labile compounds, with a higher percentage in the Brazilian crude oil (4.9 mg L-1, corresponding to 18% of total V), in comparison to the one from the biodegraded NIST 8505 (59 mg L-1, corresponding to 7% of total V). The overall methodology has a good reproducibility and provides information on elements concentrations associated with porphyrin class compounds. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000601309 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000601309 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0103-5053.20190029 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.30 n.6 2019 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318181770067968 |