Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples

Detalhes bibliográficos
Autor(a) principal: Fernandes,Aline R.
Data de Publicação: 2019
Outros Autores: Bernardo,Ricardo A., Carvalho,Thays C. de, Vaz,Boniek G., Chaves,Andréa R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000501074
Resumo: Paper spray ionization (PSI) is a promising analytical tool for direct analysis in mass spectrometry (MS). However, this technique usually uses chromatographic paper, which rarely accomplishes a stable MS signal and could vary with the sample matrix effect. In the present study, the application of graphene oxides (GO) was scrutinized as modifier paper substrate for PSI-MS methods. The developed substrate efficiency was evaluated towards creatinine determination in urine samples. The GO-PSI-MS developed method for creatinine in urine samples showed linearity in the range of 0.1 to 3.4 ppm with R2 = 0.9991. The precision was evaluated and the values were between 1.1 to 6.8% and the accuracy above 96.8%. The limit of quantification (LOQ) and limit of detection (LOD) were 0.05 and 0.17 ppm, respectively. The GO-PSI developed was compared to conventional chromatographic paper for PSI-MS methods, and the results showed that the modified paper with GO bolsters method linearity, precision, and LOQ values.
id SBQ-2_eff3aa808b0bce51f95ae24b99f0898c
oai_identifier_str oai:scielo:S0103-50532019000501074
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samplespaper spray ionizationgraphene oxidecreatinineurinemass spectrometryPaper spray ionization (PSI) is a promising analytical tool for direct analysis in mass spectrometry (MS). However, this technique usually uses chromatographic paper, which rarely accomplishes a stable MS signal and could vary with the sample matrix effect. In the present study, the application of graphene oxides (GO) was scrutinized as modifier paper substrate for PSI-MS methods. The developed substrate efficiency was evaluated towards creatinine determination in urine samples. The GO-PSI-MS developed method for creatinine in urine samples showed linearity in the range of 0.1 to 3.4 ppm with R2 = 0.9991. The precision was evaluated and the values were between 1.1 to 6.8% and the accuracy above 96.8%. The limit of quantification (LOQ) and limit of detection (LOD) were 0.05 and 0.17 ppm, respectively. The GO-PSI developed was compared to conventional chromatographic paper for PSI-MS methods, and the results showed that the modified paper with GO bolsters method linearity, precision, and LOQ values.Sociedade Brasileira de Química2019-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000501074Journal of the Brazilian Chemical Society v.30 n.5 2019reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20190007info:eu-repo/semantics/openAccessFernandes,Aline R.Bernardo,Ricardo A.Carvalho,Thays C. deVaz,Boniek G.Chaves,Andréa R.eng2019-04-02T00:00:00Zoai:scielo:S0103-50532019000501074Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2019-04-02T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
title Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
spellingShingle Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
Fernandes,Aline R.
paper spray ionization
graphene oxide
creatinine
urine
mass spectrometry
title_short Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
title_full Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
title_fullStr Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
title_full_unstemmed Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
title_sort Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
author Fernandes,Aline R.
author_facet Fernandes,Aline R.
Bernardo,Ricardo A.
Carvalho,Thays C. de
Vaz,Boniek G.
Chaves,Andréa R.
author_role author
author2 Bernardo,Ricardo A.
Carvalho,Thays C. de
Vaz,Boniek G.
Chaves,Andréa R.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Fernandes,Aline R.
Bernardo,Ricardo A.
Carvalho,Thays C. de
Vaz,Boniek G.
Chaves,Andréa R.
dc.subject.por.fl_str_mv paper spray ionization
graphene oxide
creatinine
urine
mass spectrometry
topic paper spray ionization
graphene oxide
creatinine
urine
mass spectrometry
description Paper spray ionization (PSI) is a promising analytical tool for direct analysis in mass spectrometry (MS). However, this technique usually uses chromatographic paper, which rarely accomplishes a stable MS signal and could vary with the sample matrix effect. In the present study, the application of graphene oxides (GO) was scrutinized as modifier paper substrate for PSI-MS methods. The developed substrate efficiency was evaluated towards creatinine determination in urine samples. The GO-PSI-MS developed method for creatinine in urine samples showed linearity in the range of 0.1 to 3.4 ppm with R2 = 0.9991. The precision was evaluated and the values were between 1.1 to 6.8% and the accuracy above 96.8%. The limit of quantification (LOQ) and limit of detection (LOD) were 0.05 and 0.17 ppm, respectively. The GO-PSI developed was compared to conventional chromatographic paper for PSI-MS methods, and the results showed that the modified paper with GO bolsters method linearity, precision, and LOQ values.
publishDate 2019
dc.date.none.fl_str_mv 2019-05-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000501074
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000501074
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20190007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.30 n.5 2019
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318181732319232