Monitoring of diclofenac with biomimetic sensor in batch and FIA systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000700018 |
Resumo: | The present work aims the development of a biomimetic sensor for the detection of sodium diclofenac from a glassy carbon electrode modified with copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine complex and functionalized multi-walled carbon nanotubes (MWCNT-COOH). The proposed sensor was evaluated in batch system using 0.1 mol L-1 phosphate buffer solution at pH 7.5 as electrolyte support. A linear response was obtained in the range of 4.0 × 10-5 and 6.7 × 10-4 mol L-1, with the sensitivity of 6.1 × 10(5) (± 1.5 × 10(4)) µA L mol-1 and detection limit of 1.3 × 10-5 mol L-1 using square wave voltammetry. The selectivity was studied by the sensor response in the presence of other drugs. The sensor was applied to pharmaceutical formulations and also to biological serum samples by recovery studies. When coupled to a flow injection system (FIA), the best results were obtained by applying the potential of 0.5 V vs. Ag|AgCl|KCl sat, using an injected volume of the sample of 100 µL and a flow of 1.2 mL min-1. The linear response range in flow was between 5.0 × 10-5 and 5.0 × 10-3 mol L-1, with a sensitivity of 1.6 × 10(4) (± 3.0 × 10²) µA L mol-1and a relative standard deviation of 3.5%. |
id |
SBQ-2_fdac0c20317d02f696b77676b12cf0f3 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532014000700018 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systemsbiomimetic catalystcopper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyaninediclofenacflow injection systemMWCNT-COOHglassy carbon electrodeThe present work aims the development of a biomimetic sensor for the detection of sodium diclofenac from a glassy carbon electrode modified with copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine complex and functionalized multi-walled carbon nanotubes (MWCNT-COOH). The proposed sensor was evaluated in batch system using 0.1 mol L-1 phosphate buffer solution at pH 7.5 as electrolyte support. A linear response was obtained in the range of 4.0 × 10-5 and 6.7 × 10-4 mol L-1, with the sensitivity of 6.1 × 10(5) (± 1.5 × 10(4)) µA L mol-1 and detection limit of 1.3 × 10-5 mol L-1 using square wave voltammetry. The selectivity was studied by the sensor response in the presence of other drugs. The sensor was applied to pharmaceutical formulations and also to biological serum samples by recovery studies. When coupled to a flow injection system (FIA), the best results were obtained by applying the potential of 0.5 V vs. Ag|AgCl|KCl sat, using an injected volume of the sample of 100 µL and a flow of 1.2 mL min-1. The linear response range in flow was between 5.0 × 10-5 and 5.0 × 10-3 mol L-1, with a sensitivity of 1.6 × 10(4) (± 3.0 × 10²) µA L mol-1and a relative standard deviation of 3.5%.Sociedade Brasileira de Química2014-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000700018Journal of the Brazilian Chemical Society v.25 n.7 2014reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20140108info:eu-repo/semantics/openAccessWong,AdemarMarestoni,Luiz D.Sotomayor,Maria D. P. T.eng2014-07-17T00:00:00Zoai:scielo:S0103-50532014000700018Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2014-07-17T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
title |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
spellingShingle |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems Wong,Ademar biomimetic catalyst copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine diclofenac flow injection system MWCNT-COOH glassy carbon electrode |
title_short |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
title_full |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
title_fullStr |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
title_full_unstemmed |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
title_sort |
Monitoring of diclofenac with biomimetic sensor in batch and FIA systems |
author |
Wong,Ademar |
author_facet |
Wong,Ademar Marestoni,Luiz D. Sotomayor,Maria D. P. T. |
author_role |
author |
author2 |
Marestoni,Luiz D. Sotomayor,Maria D. P. T. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Wong,Ademar Marestoni,Luiz D. Sotomayor,Maria D. P. T. |
dc.subject.por.fl_str_mv |
biomimetic catalyst copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine diclofenac flow injection system MWCNT-COOH glassy carbon electrode |
topic |
biomimetic catalyst copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine diclofenac flow injection system MWCNT-COOH glassy carbon electrode |
description |
The present work aims the development of a biomimetic sensor for the detection of sodium diclofenac from a glassy carbon electrode modified with copper(II) 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine complex and functionalized multi-walled carbon nanotubes (MWCNT-COOH). The proposed sensor was evaluated in batch system using 0.1 mol L-1 phosphate buffer solution at pH 7.5 as electrolyte support. A linear response was obtained in the range of 4.0 × 10-5 and 6.7 × 10-4 mol L-1, with the sensitivity of 6.1 × 10(5) (± 1.5 × 10(4)) µA L mol-1 and detection limit of 1.3 × 10-5 mol L-1 using square wave voltammetry. The selectivity was studied by the sensor response in the presence of other drugs. The sensor was applied to pharmaceutical formulations and also to biological serum samples by recovery studies. When coupled to a flow injection system (FIA), the best results were obtained by applying the potential of 0.5 V vs. Ag|AgCl|KCl sat, using an injected volume of the sample of 100 µL and a flow of 1.2 mL min-1. The linear response range in flow was between 5.0 × 10-5 and 5.0 × 10-3 mol L-1, with a sensitivity of 1.6 × 10(4) (± 3.0 × 10²) µA L mol-1and a relative standard deviation of 3.5%. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-07-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000700018 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000700018 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20140108 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.25 n.7 2014 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318176159137792 |