CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO

Detalhes bibliográficos
Autor(a) principal: Lopes,Emanoelli R.
Data de Publicação: 2017
Outros Autores: Medina,Aline L., Ribeiro,Anderson S., Brandalise,João N., Nunes,Adriane M.
Tipo de documento: Artigo
Idioma: por
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422017000901009
Resumo: This paper describes the optimization of a sample preparation method using response surface methodology for Al, Cd, Cu, Fe, Mg, Mn, Mo, Na, Ni and Ti determinations in samples of rice husk and rice husk ash by MIP OES. Sample preparation was performed using a reflux system adapted to the digestion tubes. This system allowed the decomposition of the samples without the necessity of replacement of the acids during this step without any loss of volatile elements. The decompositions were performed with 3.6 mL of HNO3 and 1.4 mL of H2SO4 for 205 min in a digester block at 225 ºC. The detection limit for determination of respective analytes in both samples were satisfactory. The RSDs for the analytes were less than 10%. Moreover, the accuracy of the method can be verified by recovery tests, whose values ranged from 82 to 115% for husk samples and 82 to 120% for ashes. The proposed method was presented as a simple, safe and low cost procedure being suitable for sample preparation and subsequent determination of metals by MIP OES.
id SBQ-3_20a42568b898703d44f529ff8f967113
oai_identifier_str oai:scielo:S0100-40422017000901009
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXOrice husk and rice husk ashesreflux systemmetalsMIP OESThis paper describes the optimization of a sample preparation method using response surface methodology for Al, Cd, Cu, Fe, Mg, Mn, Mo, Na, Ni and Ti determinations in samples of rice husk and rice husk ash by MIP OES. Sample preparation was performed using a reflux system adapted to the digestion tubes. This system allowed the decomposition of the samples without the necessity of replacement of the acids during this step without any loss of volatile elements. The decompositions were performed with 3.6 mL of HNO3 and 1.4 mL of H2SO4 for 205 min in a digester block at 225 ºC. The detection limit for determination of respective analytes in both samples were satisfactory. The RSDs for the analytes were less than 10%. Moreover, the accuracy of the method can be verified by recovery tests, whose values ranged from 82 to 115% for husk samples and 82 to 120% for ashes. The proposed method was presented as a simple, safe and low cost procedure being suitable for sample preparation and subsequent determination of metals by MIP OES.Sociedade Brasileira de Química2017-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422017000901009Química Nova v.40 n.9 2017reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0100-4042.20170119info:eu-repo/semantics/openAccessLopes,Emanoelli R.Medina,Aline L.Ribeiro,Anderson S.Brandalise,João N.Nunes,Adriane M.por2017-11-21T00:00:00Zoai:scielo:S0100-40422017000901009Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2017-11-21T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
title CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
spellingShingle CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
Lopes,Emanoelli R.
rice husk and rice husk ashes
reflux system
metals
MIP OES
title_short CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
title_full CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
title_fullStr CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
title_full_unstemmed CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
title_sort CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO
author Lopes,Emanoelli R.
author_facet Lopes,Emanoelli R.
Medina,Aline L.
Ribeiro,Anderson S.
Brandalise,João N.
Nunes,Adriane M.
author_role author
author2 Medina,Aline L.
Ribeiro,Anderson S.
Brandalise,João N.
Nunes,Adriane M.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Lopes,Emanoelli R.
Medina,Aline L.
Ribeiro,Anderson S.
Brandalise,João N.
Nunes,Adriane M.
dc.subject.por.fl_str_mv rice husk and rice husk ashes
reflux system
metals
MIP OES
topic rice husk and rice husk ashes
reflux system
metals
MIP OES
description This paper describes the optimization of a sample preparation method using response surface methodology for Al, Cd, Cu, Fe, Mg, Mn, Mo, Na, Ni and Ti determinations in samples of rice husk and rice husk ash by MIP OES. Sample preparation was performed using a reflux system adapted to the digestion tubes. This system allowed the decomposition of the samples without the necessity of replacement of the acids during this step without any loss of volatile elements. The decompositions were performed with 3.6 mL of HNO3 and 1.4 mL of H2SO4 for 205 min in a digester block at 225 ºC. The detection limit for determination of respective analytes in both samples were satisfactory. The RSDs for the analytes were less than 10%. Moreover, the accuracy of the method can be verified by recovery tests, whose values ranged from 82 to 115% for husk samples and 82 to 120% for ashes. The proposed method was presented as a simple, safe and low cost procedure being suitable for sample preparation and subsequent determination of metals by MIP OES.
publishDate 2017
dc.date.none.fl_str_mv 2017-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422017000901009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422017000901009
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 10.21577/0100-4042.20170119
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.40 n.9 2017
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318118436077568