Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000600032 |
Resumo: | A method using HPLC-UV was developed and validated for the determination of etoposide incorporated into polycaprolactone implants. The method was carried out in isocratic mode using a C18 column (250 x 4.6 mm; 5 µm), at 25 ºC, with acetonitrile and acetic acid 4% (70:30) as mobile phase, a flow rate of 2 mL/min, and UV detection at 285 nm. The method was linear (r² > 0.99) over the range of 5 to 65 µg/mL, precise (RSD < 5%), accurate (recovery of 98.7%), robust, selective regarding excipient of the sample, and had a quantitation limit equal to 1.76 µg/mL. The validated method can be successfully employed for routine quality control analyses. |
id |
SBQ-3_3879948892be0fa9f7bdf37f3dd9f933 |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422012000600032 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implantsvalidationetoposidepoly(ε-caprolactone)intraocular implantA method using HPLC-UV was developed and validated for the determination of etoposide incorporated into polycaprolactone implants. The method was carried out in isocratic mode using a C18 column (250 x 4.6 mm; 5 µm), at 25 ºC, with acetonitrile and acetic acid 4% (70:30) as mobile phase, a flow rate of 2 mL/min, and UV detection at 285 nm. The method was linear (r² > 0.99) over the range of 5 to 65 µg/mL, precise (RSD < 5%), accurate (recovery of 98.7%), robust, selective regarding excipient of the sample, and had a quantitation limit equal to 1.76 µg/mL. The validated method can be successfully employed for routine quality control analyses.Sociedade Brasileira de Química2012-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000600032Química Nova v.35 n.6 2012reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422012000600032info:eu-repo/semantics/openAccessSolano,Ana Gabriela ReisSilva,Gisele Rodrigues daFialho,Silvia LigórioCunha Júnior,Armando da SilvaPianetti,Gérson Antônioeng2012-07-25T00:00:00Zoai:scielo:S0100-40422012000600032Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2012-07-25T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
title |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
spellingShingle |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants Solano,Ana Gabriela Reis validation etoposide poly(ε-caprolactone) intraocular implant |
title_short |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
title_full |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
title_fullStr |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
title_full_unstemmed |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
title_sort |
Development and validation of a High Performance Liquid Chromatographic method for determination of etoposide in biodegradable polymeric implants |
author |
Solano,Ana Gabriela Reis |
author_facet |
Solano,Ana Gabriela Reis Silva,Gisele Rodrigues da Fialho,Silvia Ligório Cunha Júnior,Armando da Silva Pianetti,Gérson Antônio |
author_role |
author |
author2 |
Silva,Gisele Rodrigues da Fialho,Silvia Ligório Cunha Júnior,Armando da Silva Pianetti,Gérson Antônio |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Solano,Ana Gabriela Reis Silva,Gisele Rodrigues da Fialho,Silvia Ligório Cunha Júnior,Armando da Silva Pianetti,Gérson Antônio |
dc.subject.por.fl_str_mv |
validation etoposide poly(ε-caprolactone) intraocular implant |
topic |
validation etoposide poly(ε-caprolactone) intraocular implant |
description |
A method using HPLC-UV was developed and validated for the determination of etoposide incorporated into polycaprolactone implants. The method was carried out in isocratic mode using a C18 column (250 x 4.6 mm; 5 µm), at 25 ºC, with acetonitrile and acetic acid 4% (70:30) as mobile phase, a flow rate of 2 mL/min, and UV detection at 285 nm. The method was linear (r² > 0.99) over the range of 5 to 65 µg/mL, precise (RSD < 5%), accurate (recovery of 98.7%), robust, selective regarding excipient of the sample, and had a quantitation limit equal to 1.76 µg/mL. The validated method can be successfully employed for routine quality control analyses. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000600032 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000600032 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422012000600032 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.35 n.6 2012 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318113570684928 |