Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants

Detalhes bibliográficos
Autor(a) principal: Saliba,Juliana Barbosa
Data de Publicação: 2011
Outros Autores: Cunha Junior,Armando da Silva, Gomes,Elionai Cassiana de Lima, Mansur,Herman Sander, Silva,Gisele Rodrigues da
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000100026
Resumo: An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
id SBQ-3_f0976b9ba2b2725cc2048a9691c35842
oai_identifier_str oai:scielo:S0100-40422011000100026
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implantscyclosporine-Abiodegradable intraocular implantvalidationAn HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.Sociedade Brasileira de Química2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000100026Química Nova v.34 n.1 2011reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422011000100026info:eu-repo/semantics/openAccessSaliba,Juliana BarbosaCunha Junior,Armando da SilvaGomes,Elionai Cassiana de LimaMansur,Herman SanderSilva,Gisele Rodrigues daeng2011-02-10T00:00:00Zoai:scielo:S0100-40422011000100026Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2011-02-10T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
title Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
spellingShingle Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
Saliba,Juliana Barbosa
cyclosporine-A
biodegradable intraocular implant
validation
title_short Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
title_full Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
title_fullStr Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
title_full_unstemmed Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
title_sort Development and validation of a high performance liquid chromatographic method for determination of cyclosporine-A from biodegradable intraocular implants
author Saliba,Juliana Barbosa
author_facet Saliba,Juliana Barbosa
Cunha Junior,Armando da Silva
Gomes,Elionai Cassiana de Lima
Mansur,Herman Sander
Silva,Gisele Rodrigues da
author_role author
author2 Cunha Junior,Armando da Silva
Gomes,Elionai Cassiana de Lima
Mansur,Herman Sander
Silva,Gisele Rodrigues da
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Saliba,Juliana Barbosa
Cunha Junior,Armando da Silva
Gomes,Elionai Cassiana de Lima
Mansur,Herman Sander
Silva,Gisele Rodrigues da
dc.subject.por.fl_str_mv cyclosporine-A
biodegradable intraocular implant
validation
topic cyclosporine-A
biodegradable intraocular implant
validation
description An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000100026
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000100026
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-40422011000100026
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.34 n.1 2011
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318111553224704