An augmented patient-specific approach to administration of contrast agent for CT renal angiography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | International Braz J Urol (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382019000501022 |
Resumo: | ABSTRACT Purpose This hybrid retrospective and prospective study performed on 200 consecutive patients undergoing renal CTA, investigates the opacification of renal vasculature, radiation dose, and reader confidence. Materials and Methods 100 patients were assigned retrospectively to protocol A and the other 100 were allocated prospectively to protocol B. Both protocols implemented a contrast material and saline flow rate of 4.5 mL/sec. Protocol A utilized a 100 mL of low-osmolar nonionic IV contrast material (Ioversol 350 mg I/mL) while protocol B employed a patient-tailored contrast media formula using iso-osmolar non-ionic (Iodixanol 320 mg I/mL). Results Arterial opacification in the abdominal aorta and in the bilateral main proximal renal arteries demonstrated no statistical significance (p>0.05). Only the main distal renal artery of the left kidney in protocol B was statistically significant (p<0.046). In the venous circulation, the IVC demonstrated a significant reduction in opacification in protocol B (59.39 HU ± 19.39) compared to A (87.74 HU ± 34.06) (p<0.001). Mean CNR for protocol A (22.68 HU ± 13.72) was significantly higher than that of protocol B (14.75 HU ± 5.76 p< 0.0001). Effective dose was significantly reduced in protocol B (2.46 ± 0.74 mSv) compared to A (3.07 ± 0.68 mSv) (p<0.001). Mean contrast media volume was reduced in protocol B (44.56 ± 14.32 mL) with lower iodine concentration. ROC analysis demonstrated significantly higher area under the ROC curve for protocol B (p< 0.0001), with inter-reader agreement increasing from moderate to excellent in renal arterial visualization. Conclusion Employing a patient-tailored contrast media injection protocol shows a significant refinement in the visualization of renal vasculature and reader confidence during renal CTA. |
id |
SBU-1_3b8089f8e58646d0fe0b2bb4989b8806 |
---|---|
oai_identifier_str |
oai:scielo:S1677-55382019000501022 |
network_acronym_str |
SBU-1 |
network_name_str |
International Braz J Urol (Online) |
repository_id_str |
|
spelling |
An augmented patient-specific approach to administration of contrast agent for CT renal angiographyComputed Tomography AngiographyKidneyRadiation DosageABSTRACT Purpose This hybrid retrospective and prospective study performed on 200 consecutive patients undergoing renal CTA, investigates the opacification of renal vasculature, radiation dose, and reader confidence. Materials and Methods 100 patients were assigned retrospectively to protocol A and the other 100 were allocated prospectively to protocol B. Both protocols implemented a contrast material and saline flow rate of 4.5 mL/sec. Protocol A utilized a 100 mL of low-osmolar nonionic IV contrast material (Ioversol 350 mg I/mL) while protocol B employed a patient-tailored contrast media formula using iso-osmolar non-ionic (Iodixanol 320 mg I/mL). Results Arterial opacification in the abdominal aorta and in the bilateral main proximal renal arteries demonstrated no statistical significance (p>0.05). Only the main distal renal artery of the left kidney in protocol B was statistically significant (p<0.046). In the venous circulation, the IVC demonstrated a significant reduction in opacification in protocol B (59.39 HU ± 19.39) compared to A (87.74 HU ± 34.06) (p<0.001). Mean CNR for protocol A (22.68 HU ± 13.72) was significantly higher than that of protocol B (14.75 HU ± 5.76 p< 0.0001). Effective dose was significantly reduced in protocol B (2.46 ± 0.74 mSv) compared to A (3.07 ± 0.68 mSv) (p<0.001). Mean contrast media volume was reduced in protocol B (44.56 ± 14.32 mL) with lower iodine concentration. ROC analysis demonstrated significantly higher area under the ROC curve for protocol B (p< 0.0001), with inter-reader agreement increasing from moderate to excellent in renal arterial visualization. Conclusion Employing a patient-tailored contrast media injection protocol shows a significant refinement in the visualization of renal vasculature and reader confidence during renal CTA.Sociedade Brasileira de Urologia2019-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382019000501022International braz j urol v.45 n.5 2019reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/s1677-5538.ibju.2018.0366info:eu-repo/semantics/openAccessSaade,CharbelHamieh,NadineDeeb,Ibrahim Al-SheikhHaddad,MauriceAbi-Ghanem,Alain S.Ghieh,DiamondEl-Merhi,Fadieng2019-11-05T00:00:00Zoai:scielo:S1677-55382019000501022Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2019-11-05T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false |
dc.title.none.fl_str_mv |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
title |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
spellingShingle |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography Saade,Charbel Computed Tomography Angiography Kidney Radiation Dosage |
title_short |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
title_full |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
title_fullStr |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
title_full_unstemmed |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
title_sort |
An augmented patient-specific approach to administration of contrast agent for CT renal angiography |
author |
Saade,Charbel |
author_facet |
Saade,Charbel Hamieh,Nadine Deeb,Ibrahim Al-Sheikh Haddad,Maurice Abi-Ghanem,Alain S. Ghieh,Diamond El-Merhi,Fadi |
author_role |
author |
author2 |
Hamieh,Nadine Deeb,Ibrahim Al-Sheikh Haddad,Maurice Abi-Ghanem,Alain S. Ghieh,Diamond El-Merhi,Fadi |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Saade,Charbel Hamieh,Nadine Deeb,Ibrahim Al-Sheikh Haddad,Maurice Abi-Ghanem,Alain S. Ghieh,Diamond El-Merhi,Fadi |
dc.subject.por.fl_str_mv |
Computed Tomography Angiography Kidney Radiation Dosage |
topic |
Computed Tomography Angiography Kidney Radiation Dosage |
description |
ABSTRACT Purpose This hybrid retrospective and prospective study performed on 200 consecutive patients undergoing renal CTA, investigates the opacification of renal vasculature, radiation dose, and reader confidence. Materials and Methods 100 patients were assigned retrospectively to protocol A and the other 100 were allocated prospectively to protocol B. Both protocols implemented a contrast material and saline flow rate of 4.5 mL/sec. Protocol A utilized a 100 mL of low-osmolar nonionic IV contrast material (Ioversol 350 mg I/mL) while protocol B employed a patient-tailored contrast media formula using iso-osmolar non-ionic (Iodixanol 320 mg I/mL). Results Arterial opacification in the abdominal aorta and in the bilateral main proximal renal arteries demonstrated no statistical significance (p>0.05). Only the main distal renal artery of the left kidney in protocol B was statistically significant (p<0.046). In the venous circulation, the IVC demonstrated a significant reduction in opacification in protocol B (59.39 HU ± 19.39) compared to A (87.74 HU ± 34.06) (p<0.001). Mean CNR for protocol A (22.68 HU ± 13.72) was significantly higher than that of protocol B (14.75 HU ± 5.76 p< 0.0001). Effective dose was significantly reduced in protocol B (2.46 ± 0.74 mSv) compared to A (3.07 ± 0.68 mSv) (p<0.001). Mean contrast media volume was reduced in protocol B (44.56 ± 14.32 mL) with lower iodine concentration. ROC analysis demonstrated significantly higher area under the ROC curve for protocol B (p< 0.0001), with inter-reader agreement increasing from moderate to excellent in renal arterial visualization. Conclusion Employing a patient-tailored contrast media injection protocol shows a significant refinement in the visualization of renal vasculature and reader confidence during renal CTA. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382019000501022 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382019000501022 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1677-5538.ibju.2018.0366 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Urologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Urologia |
dc.source.none.fl_str_mv |
International braz j urol v.45 n.5 2019 reponame:International Braz J Urol (Online) instname:Sociedade Brasileira de Urologia (SBU) instacron:SBU |
instname_str |
Sociedade Brasileira de Urologia (SBU) |
instacron_str |
SBU |
institution |
SBU |
reponame_str |
International Braz J Urol (Online) |
collection |
International Braz J Urol (Online) |
repository.name.fl_str_mv |
International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU) |
repository.mail.fl_str_mv |
||brazjurol@brazjurol.com.br |
_version_ |
1750318077190340608 |