Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences

Detalhes bibliográficos
Autor(a) principal: Cheng,Wai C.
Data de Publicação: 2004
Outros Autores: Ng,Fai C., Chan,Kwok C., Cheung,Yuen H., Chan,Wai L., Wong,Sang W.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382004000600003
Resumo: PURPOSE: To compare the accuracy of estimating prostatic volume with digital rectal examination (DRE) by urological staffs with different experiences. Measurement of prostatic volume with transrectal ultrasonography (TRUS) serves as the reference standard. MATERIALS AND METHODS: Thirty-nine consecutive male patients admitted with acute urinary retention had their prostatic volume estimated with DRE by a urology junior trainee, a urology higher trainee and a trained urologist. All patients had TRUS to measure their prostatic volumes. Pearson correlation coefficients (r) were used to assess the relationships between the prostatic volume measured with TRUS and that estimated with DRE by the 3 urological staffs. Wilcoxon signed ranks tests were used to compare the discrepancies between the prostatic volume measured with TRUS and that estimated with DRE for the 3 Urological staffs, and to assess the inter-observer differences of these discrepancies. RESULTS: The correlation coefficients for the 3 urological staffs were r = 0.573 for the urology junior trainee, r = 0.541 for the urology higher trainee, and r = 0.640 for the trained urologist. The median discrepancies between the prostatic volume measured with TRUS and that estimated with DRE were -9.1 mL for the urology junior trainee, -1.3 mL for the urology higher trainee and 0.9 mL for the trained urologist. These discrepancies were statistically significant only in the case of urology junior trainee (p = 0.015, Wilcoxon signed ranks test). The difference in these discrepancies was statistically significant only between the urology junior trainee and the trained urologist (p = 0.003, Wilcoxon signed ranks test). CONCLUSIONS: The trained urologist was more accurate in estimating prostatic volume with DRE than the urology junior trainee.
id SBU-1_72cfd425884f3e9f8e11f8adfea44b04
oai_identifier_str oai:scielo:S1677-55382004000600003
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiencesprostatephysical examinationinter observer variationultrasonographyPURPOSE: To compare the accuracy of estimating prostatic volume with digital rectal examination (DRE) by urological staffs with different experiences. Measurement of prostatic volume with transrectal ultrasonography (TRUS) serves as the reference standard. MATERIALS AND METHODS: Thirty-nine consecutive male patients admitted with acute urinary retention had their prostatic volume estimated with DRE by a urology junior trainee, a urology higher trainee and a trained urologist. All patients had TRUS to measure their prostatic volumes. Pearson correlation coefficients (r) were used to assess the relationships between the prostatic volume measured with TRUS and that estimated with DRE by the 3 urological staffs. Wilcoxon signed ranks tests were used to compare the discrepancies between the prostatic volume measured with TRUS and that estimated with DRE for the 3 Urological staffs, and to assess the inter-observer differences of these discrepancies. RESULTS: The correlation coefficients for the 3 urological staffs were r = 0.573 for the urology junior trainee, r = 0.541 for the urology higher trainee, and r = 0.640 for the trained urologist. The median discrepancies between the prostatic volume measured with TRUS and that estimated with DRE were -9.1 mL for the urology junior trainee, -1.3 mL for the urology higher trainee and 0.9 mL for the trained urologist. These discrepancies were statistically significant only in the case of urology junior trainee (p = 0.015, Wilcoxon signed ranks test). The difference in these discrepancies was statistically significant only between the urology junior trainee and the trained urologist (p = 0.003, Wilcoxon signed ranks test). CONCLUSIONS: The trained urologist was more accurate in estimating prostatic volume with DRE than the urology junior trainee.Sociedade Brasileira de Urologia2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382004000600003International braz j urol v.30 n.6 2004reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-55382004000600003info:eu-repo/semantics/openAccessCheng,Wai C.Ng,Fai C.Chan,Kwok C.Cheung,Yuen H.Chan,Wai L.Wong,Sang W.eng2005-03-08T00:00:00Zoai:scielo:S1677-55382004000600003Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2005-03-08T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
title Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
spellingShingle Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
Cheng,Wai C.
prostate
physical examination
inter observer variation
ultrasonography
title_short Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
title_full Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
title_fullStr Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
title_full_unstemmed Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
title_sort Interobserver variation of prostatic volume estimation with digital rectal examination by urological staffs with different experiences
author Cheng,Wai C.
author_facet Cheng,Wai C.
Ng,Fai C.
Chan,Kwok C.
Cheung,Yuen H.
Chan,Wai L.
Wong,Sang W.
author_role author
author2 Ng,Fai C.
Chan,Kwok C.
Cheung,Yuen H.
Chan,Wai L.
Wong,Sang W.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Cheng,Wai C.
Ng,Fai C.
Chan,Kwok C.
Cheung,Yuen H.
Chan,Wai L.
Wong,Sang W.
dc.subject.por.fl_str_mv prostate
physical examination
inter observer variation
ultrasonography
topic prostate
physical examination
inter observer variation
ultrasonography
description PURPOSE: To compare the accuracy of estimating prostatic volume with digital rectal examination (DRE) by urological staffs with different experiences. Measurement of prostatic volume with transrectal ultrasonography (TRUS) serves as the reference standard. MATERIALS AND METHODS: Thirty-nine consecutive male patients admitted with acute urinary retention had their prostatic volume estimated with DRE by a urology junior trainee, a urology higher trainee and a trained urologist. All patients had TRUS to measure their prostatic volumes. Pearson correlation coefficients (r) were used to assess the relationships between the prostatic volume measured with TRUS and that estimated with DRE by the 3 urological staffs. Wilcoxon signed ranks tests were used to compare the discrepancies between the prostatic volume measured with TRUS and that estimated with DRE for the 3 Urological staffs, and to assess the inter-observer differences of these discrepancies. RESULTS: The correlation coefficients for the 3 urological staffs were r = 0.573 for the urology junior trainee, r = 0.541 for the urology higher trainee, and r = 0.640 for the trained urologist. The median discrepancies between the prostatic volume measured with TRUS and that estimated with DRE were -9.1 mL for the urology junior trainee, -1.3 mL for the urology higher trainee and 0.9 mL for the trained urologist. These discrepancies were statistically significant only in the case of urology junior trainee (p = 0.015, Wilcoxon signed ranks test). The difference in these discrepancies was statistically significant only between the urology junior trainee and the trained urologist (p = 0.003, Wilcoxon signed ranks test). CONCLUSIONS: The trained urologist was more accurate in estimating prostatic volume with DRE than the urology junior trainee.
publishDate 2004
dc.date.none.fl_str_mv 2004-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382004000600003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382004000600003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1677-55382004000600003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.30 n.6 2004
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318069043953664