Semen cryopreservation protocols of Mangalarga Marchador stallions

Detalhes bibliográficos
Autor(a) principal: Candeias,Marcela Leite
Data de Publicação: 2012
Outros Autores: Alvarenga,Marco Antonio, Carmo,Márcio Teoro do, Ferreira,Heder Nunes, Maior,Mônica Russo Souto, Torres Filho,Rodolpho de Almeida, Rodrigues,André Luís Rios, Brandão,Felipe Zandonadi
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Zootecnia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-35982012000900004
Resumo: The effect of the utilization of three semen protocols (Inra 82®, Merck Gema and Botu-crio®) and two filling techniques (0.25 and 0.50 mL straws) in Mangalarga Marchador stallions were studied in this experiment. Sperm parameters were assessed during processing and post-freezing. No interactions between the protocols and type of filling were observed, so they were assessed separately. Sperm parameters were not altered when the extender was added to the centrifugation; however, there was reduction of motility and strength when freezing extenders were added. The Botu-crio® protocol preserved the parameters of total and progressive sperm motility, smoothed path velocity (µm/s), straight line velocity (µm/s), track velocity (µm/s) and the average and fast spermatozoa percentage better than the others. No difference between the extenders for the percentage of sperm integrity was observed. There was no difference in the responses studied on the filling techniques. The stallions presented better freezing with the use of the Botu-crio® protocol. The best post-freezing viability results were found for semen frozen using the Botu-crio® protocol and there were no differences concerning the sperm quality comparing 0.25 and 0.50 mL straws.
id SBZ-1_9334d119b9416e8b2f4e957457eade68
oai_identifier_str oai:scielo:S1516-35982012000900004
network_acronym_str SBZ-1
network_name_str Revista Brasileira de Zootecnia (Online)
repository_id_str
spelling Semen cryopreservation protocols of Mangalarga Marchador stallionsejaculatedequineextenderstrawThe effect of the utilization of three semen protocols (Inra 82®, Merck Gema and Botu-crio®) and two filling techniques (0.25 and 0.50 mL straws) in Mangalarga Marchador stallions were studied in this experiment. Sperm parameters were assessed during processing and post-freezing. No interactions between the protocols and type of filling were observed, so they were assessed separately. Sperm parameters were not altered when the extender was added to the centrifugation; however, there was reduction of motility and strength when freezing extenders were added. The Botu-crio® protocol preserved the parameters of total and progressive sperm motility, smoothed path velocity (µm/s), straight line velocity (µm/s), track velocity (µm/s) and the average and fast spermatozoa percentage better than the others. No difference between the extenders for the percentage of sperm integrity was observed. There was no difference in the responses studied on the filling techniques. The stallions presented better freezing with the use of the Botu-crio® protocol. The best post-freezing viability results were found for semen frozen using the Botu-crio® protocol and there were no differences concerning the sperm quality comparing 0.25 and 0.50 mL straws.Sociedade Brasileira de Zootecnia2012-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-35982012000900004Revista Brasileira de Zootecnia v.41 n.9 2012reponame:Revista Brasileira de Zootecnia (Online)instname:Sociedade Brasileira de Zootecnia (SBZ)instacron:SBZ10.1590/S1516-35982012000900004info:eu-repo/semantics/openAccessCandeias,Marcela LeiteAlvarenga,Marco AntonioCarmo,Márcio Teoro doFerreira,Heder NunesMaior,Mônica Russo SoutoTorres Filho,Rodolpho de AlmeidaRodrigues,André Luís RiosBrandão,Felipe Zandonadieng2012-10-02T00:00:00Zoai:scielo:S1516-35982012000900004Revistahttps://www.rbz.org.br/pt-br/https://old.scielo.br/oai/scielo-oai.php||bz@sbz.org.br|| secretariarbz@sbz.org.br1806-92901516-3598opendoar:2012-10-02T00:00Revista Brasileira de Zootecnia (Online) - Sociedade Brasileira de Zootecnia (SBZ)false
dc.title.none.fl_str_mv Semen cryopreservation protocols of Mangalarga Marchador stallions
title Semen cryopreservation protocols of Mangalarga Marchador stallions
spellingShingle Semen cryopreservation protocols of Mangalarga Marchador stallions
Candeias,Marcela Leite
ejaculated
equine
extender
straw
title_short Semen cryopreservation protocols of Mangalarga Marchador stallions
title_full Semen cryopreservation protocols of Mangalarga Marchador stallions
title_fullStr Semen cryopreservation protocols of Mangalarga Marchador stallions
title_full_unstemmed Semen cryopreservation protocols of Mangalarga Marchador stallions
title_sort Semen cryopreservation protocols of Mangalarga Marchador stallions
author Candeias,Marcela Leite
author_facet Candeias,Marcela Leite
Alvarenga,Marco Antonio
Carmo,Márcio Teoro do
Ferreira,Heder Nunes
Maior,Mônica Russo Souto
Torres Filho,Rodolpho de Almeida
Rodrigues,André Luís Rios
Brandão,Felipe Zandonadi
author_role author
author2 Alvarenga,Marco Antonio
Carmo,Márcio Teoro do
Ferreira,Heder Nunes
Maior,Mônica Russo Souto
Torres Filho,Rodolpho de Almeida
Rodrigues,André Luís Rios
Brandão,Felipe Zandonadi
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Candeias,Marcela Leite
Alvarenga,Marco Antonio
Carmo,Márcio Teoro do
Ferreira,Heder Nunes
Maior,Mônica Russo Souto
Torres Filho,Rodolpho de Almeida
Rodrigues,André Luís Rios
Brandão,Felipe Zandonadi
dc.subject.por.fl_str_mv ejaculated
equine
extender
straw
topic ejaculated
equine
extender
straw
description The effect of the utilization of three semen protocols (Inra 82®, Merck Gema and Botu-crio®) and two filling techniques (0.25 and 0.50 mL straws) in Mangalarga Marchador stallions were studied in this experiment. Sperm parameters were assessed during processing and post-freezing. No interactions between the protocols and type of filling were observed, so they were assessed separately. Sperm parameters were not altered when the extender was added to the centrifugation; however, there was reduction of motility and strength when freezing extenders were added. The Botu-crio® protocol preserved the parameters of total and progressive sperm motility, smoothed path velocity (µm/s), straight line velocity (µm/s), track velocity (µm/s) and the average and fast spermatozoa percentage better than the others. No difference between the extenders for the percentage of sperm integrity was observed. There was no difference in the responses studied on the filling techniques. The stallions presented better freezing with the use of the Botu-crio® protocol. The best post-freezing viability results were found for semen frozen using the Botu-crio® protocol and there were no differences concerning the sperm quality comparing 0.25 and 0.50 mL straws.
publishDate 2012
dc.date.none.fl_str_mv 2012-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-35982012000900004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-35982012000900004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1516-35982012000900004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Zootecnia
publisher.none.fl_str_mv Sociedade Brasileira de Zootecnia
dc.source.none.fl_str_mv Revista Brasileira de Zootecnia v.41 n.9 2012
reponame:Revista Brasileira de Zootecnia (Online)
instname:Sociedade Brasileira de Zootecnia (SBZ)
instacron:SBZ
instname_str Sociedade Brasileira de Zootecnia (SBZ)
instacron_str SBZ
institution SBZ
reponame_str Revista Brasileira de Zootecnia (Online)
collection Revista Brasileira de Zootecnia (Online)
repository.name.fl_str_mv Revista Brasileira de Zootecnia (Online) - Sociedade Brasileira de Zootecnia (SBZ)
repository.mail.fl_str_mv ||bz@sbz.org.br|| secretariarbz@sbz.org.br
_version_ 1750318150083149824