Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa

Detalhes bibliográficos
Autor(a) principal: Steffens, Clarice
Data de Publicação: 2012
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/259
Resumo: The great interest to develop microcantilevers sensors is due to several desirable properties, in particular the ability to adjust the size and structure, thus increasing the perspectives for the construction of new sensor systems. In this work, we developed functionalized microcantilever sensors with conducting polymers to detect relative humidity, volatile organic compounds and insect pheromones. The development was based on a systematic investigation, since the polymer synthesis and the film formation until the sensing step. For this purpose, we studied two treatments to clean the microcantilevers surfaces (plasma and piranha solution). Also, appropriate ways for the sensors functionalization were evaluated, using spin-coating and thermoelastic probe techniques. The polyaniline solutions were obtained by the in-situ and interfacial synthesis. This way, the doping, morphology and the polymer structure have been investigated by the AFM, UV-Vis, FTIR, diffraction and FE-SEM techniques, and likewise the film properties. It allowed us to optimize the preparation conditions of the polyaniline films on the surface of the microcantilevers sensors to detect relative humidity and volatiles. Also, it was possible to develop sensors with polyaniline thin films, capable to detect 1 ppmv of relative humidity, and this shows that they can be used to measure large limits of detection. Moreover, the functionalized microcantilevers sensors showed a fast response time, repeatability over several cycles and exhibited lifetime longer than 6 months. The coated microcantilevers sensors showed an excellent response to the volatile organic compounds (VOCs), indicating that the sensitive layer was xiv appropriate for detection of these volatiles. The sensitivity of these sensors at VOCs increased with the polarity, thus the methanol compound showed the greatest sensitivity. It was possible to detect and evaluate different concentrations of the pheromone 2-heptanone, at different temperatures. The microcantilever sensors response not only showed an excellent sensitivity, but also a fast response time. It was observed an excellent response to deflection of the microcantilever sensors when exposed to volatile during the banana ripeness.
id SCAR_1e1a3e4d942550c7f05d770e4ae08c86
oai_identifier_str oai:repositorio.ufscar.br:ufscar/259
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Steffens, ClariceHerrmann Júnior, Paulo Sérgio de Paulahttp://lattes.cnpq.br/3478230611350302http://lattes.cnpq.br/822449886727079968541ae8-02a8-49b2-b501-45e97cdd4aca2016-06-02T19:02:41Z2013-01-162016-06-02T19:02:41Z2012-05-31STEFFENS, Clarice. Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa. 2012. 192 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2012.https://repositorio.ufscar.br/handle/ufscar/259The great interest to develop microcantilevers sensors is due to several desirable properties, in particular the ability to adjust the size and structure, thus increasing the perspectives for the construction of new sensor systems. In this work, we developed functionalized microcantilever sensors with conducting polymers to detect relative humidity, volatile organic compounds and insect pheromones. The development was based on a systematic investigation, since the polymer synthesis and the film formation until the sensing step. For this purpose, we studied two treatments to clean the microcantilevers surfaces (plasma and piranha solution). Also, appropriate ways for the sensors functionalization were evaluated, using spin-coating and thermoelastic probe techniques. The polyaniline solutions were obtained by the in-situ and interfacial synthesis. This way, the doping, morphology and the polymer structure have been investigated by the AFM, UV-Vis, FTIR, diffraction and FE-SEM techniques, and likewise the film properties. It allowed us to optimize the preparation conditions of the polyaniline films on the surface of the microcantilevers sensors to detect relative humidity and volatiles. Also, it was possible to develop sensors with polyaniline thin films, capable to detect 1 ppmv of relative humidity, and this shows that they can be used to measure large limits of detection. Moreover, the functionalized microcantilevers sensors showed a fast response time, repeatability over several cycles and exhibited lifetime longer than 6 months. The coated microcantilevers sensors showed an excellent response to the volatile organic compounds (VOCs), indicating that the sensitive layer was xiv appropriate for detection of these volatiles. The sensitivity of these sensors at VOCs increased with the polarity, thus the methanol compound showed the greatest sensitivity. It was possible to detect and evaluate different concentrations of the pheromone 2-heptanone, at different temperatures. The microcantilever sensors response not only showed an excellent sensitivity, but also a fast response time. It was observed an excellent response to deflection of the microcantilever sensors when exposed to volatile during the banana ripeness.O grande interesse em desenvolver sensores de microcantilevers é devido às várias propriedades desejáveis, em particular a capacidade de adaptar o tamanho e a estrutura, aumentando, dessa forma, as perspectivas para a construção de novos sistemas de sensoriamento. Neste trabalho foram desenvolvidos nanossensores de microcantilever funcionalizados com polianilina, no estado de oxidação esmeraldina, para detecção de umidade relativa, de compostos orgânicos voláteis e, potenciais aplicações para detecção de feromônios de insetos e no amadurecimento de frutas. Para isso, o desenvolvimento se baseou em uma investigação sistemática, desde a síntese do polímero e a formação de filmes até a etapa de sensoriamento. Para tal, foram estudados dois tratamentos de limpeza das superfícies dos microcantilevers, o plasma e a solução piranha . Também foram avaliadas maneiras adequadas para a funcionalização dos sensores, empregando as técnicas de spin-coating, in-situ e sonda termoelástica à partir de soluções de polianilina obtidas pelas sínteses interfacial e in-situ, para a deposição de um filme fino em somente um lado da superfície do microcantilever. Dessa forma, a dopagem, cristalinidade e estrutura do polímero foram investigadas por meio das técnicas de UV-Vis, FTIR, difratometria e FE-MEV e, por conseguinte, as propriedades dos filmes. Estes estudos permitiram aperfeiçoar as condições de preparação dos filmes de polianilina sobre a superfície dos sensores de microcantilevers, para detecção de umidade relativa (%) e compostos orgânicos voláteis (COVs). Foi possível desenvolver sensores com filmes finos de polianilina, capazes de detectar umidade relativa até 1 ppmv, indicando, portanto, que os sensores xii desenvolvidos podem ser usados para medir grandes limites de detecção. Além disso, os sensores de microcantilevers funcionalizados apresentaram um tempo de resposta rápido, foram repetitivos a vários ciclos e apresentaram uma durabilidade maior que 6 meses. Os sensores de microcantilevers funcionalizados apresentaram uma excelente reposta aos COVs, indicando que a camada sensitiva foi adequada para detecção desses voláteis. A sensitividade dos sensores de microcantilever funcionalizados aos COVs aumentou com o aumento da polaridade do volátil, assim o composto que apresentou maior sensitividade foi o metanol. Foi possível avaliar e detectar diferentes concentrações do feromônio 2- heptanona em diferentes temperaturas. Os sensores mostraram uma excelente sensitividade e um tempo de resposta rápido. Foi observada uma excelente resposta de deflexão dos sensores de microcantilever quando expostos aos voláteis, durante o amadurecimento da banana.Universidade Federal de Minas Geraisapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Biotecnologia - PPGBiotecUFSCarBRBiotecnologiaMicrocantileverPolianilinaUmidade relativaCompostos orgânicos voláteisFeromôniosNanossensoresNanosensorsMicrocantileversConducting polymersRelative humidityVolatilePheromonesOUTROSDesenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-1-1bc47636f-2f51-4b82-91f7-484701cb0784info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL4784.pdfapplication/pdf6177335https://repositorio.ufscar.br/bitstream/ufscar/259/1/4784.pdfd4efe41cda16378eef382581c4b2c468MD51TEXT4784.pdf.txt4784.pdf.txtExtracted texttext/plain271576https://repositorio.ufscar.br/bitstream/ufscar/259/2/4784.pdf.txtb399fcb8d509f4a228a045b142e4736cMD52THUMBNAIL4784.pdf.jpg4784.pdf.jpgIM Thumbnailimage/jpeg6482https://repositorio.ufscar.br/bitstream/ufscar/259/3/4784.pdf.jpg3985f206ad123e4abd737a6d45ae7c92MD53ufscar/2592023-09-18 18:31:19.138oai:repositorio.ufscar.br:ufscar/259Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:19Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
title Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
spellingShingle Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
Steffens, Clarice
Biotecnologia
Microcantilever
Polianilina
Umidade relativa
Compostos orgânicos voláteis
Feromônios
Nanossensores
Nanosensors
Microcantilevers
Conducting polymers
Relative humidity
Volatile
Pheromones
OUTROS
title_short Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
title_full Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
title_fullStr Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
title_full_unstemmed Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
title_sort Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa
author Steffens, Clarice
author_facet Steffens, Clarice
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/8224498867270799
dc.contributor.author.fl_str_mv Steffens, Clarice
dc.contributor.advisor1.fl_str_mv Herrmann Júnior, Paulo Sérgio de Paula
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3478230611350302
dc.contributor.authorID.fl_str_mv 68541ae8-02a8-49b2-b501-45e97cdd4aca
contributor_str_mv Herrmann Júnior, Paulo Sérgio de Paula
dc.subject.por.fl_str_mv Biotecnologia
Microcantilever
Polianilina
Umidade relativa
Compostos orgânicos voláteis
Feromônios
Nanossensores
topic Biotecnologia
Microcantilever
Polianilina
Umidade relativa
Compostos orgânicos voláteis
Feromônios
Nanossensores
Nanosensors
Microcantilevers
Conducting polymers
Relative humidity
Volatile
Pheromones
OUTROS
dc.subject.eng.fl_str_mv Nanosensors
Microcantilevers
Conducting polymers
Relative humidity
Volatile
Pheromones
dc.subject.cnpq.fl_str_mv OUTROS
description The great interest to develop microcantilevers sensors is due to several desirable properties, in particular the ability to adjust the size and structure, thus increasing the perspectives for the construction of new sensor systems. In this work, we developed functionalized microcantilever sensors with conducting polymers to detect relative humidity, volatile organic compounds and insect pheromones. The development was based on a systematic investigation, since the polymer synthesis and the film formation until the sensing step. For this purpose, we studied two treatments to clean the microcantilevers surfaces (plasma and piranha solution). Also, appropriate ways for the sensors functionalization were evaluated, using spin-coating and thermoelastic probe techniques. The polyaniline solutions were obtained by the in-situ and interfacial synthesis. This way, the doping, morphology and the polymer structure have been investigated by the AFM, UV-Vis, FTIR, diffraction and FE-SEM techniques, and likewise the film properties. It allowed us to optimize the preparation conditions of the polyaniline films on the surface of the microcantilevers sensors to detect relative humidity and volatiles. Also, it was possible to develop sensors with polyaniline thin films, capable to detect 1 ppmv of relative humidity, and this shows that they can be used to measure large limits of detection. Moreover, the functionalized microcantilevers sensors showed a fast response time, repeatability over several cycles and exhibited lifetime longer than 6 months. The coated microcantilevers sensors showed an excellent response to the volatile organic compounds (VOCs), indicating that the sensitive layer was xiv appropriate for detection of these volatiles. The sensitivity of these sensors at VOCs increased with the polarity, thus the methanol compound showed the greatest sensitivity. It was possible to detect and evaluate different concentrations of the pheromone 2-heptanone, at different temperatures. The microcantilever sensors response not only showed an excellent sensitivity, but also a fast response time. It was observed an excellent response to deflection of the microcantilever sensors when exposed to volatile during the banana ripeness.
publishDate 2012
dc.date.issued.fl_str_mv 2012-05-31
dc.date.available.fl_str_mv 2013-01-16
2016-06-02T19:02:41Z
dc.date.accessioned.fl_str_mv 2016-06-02T19:02:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv STEFFENS, Clarice. Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa. 2012. 192 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2012.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/259
identifier_str_mv STEFFENS, Clarice. Desenvolvimento de microcantilever funcionalizado com polímero condutor para a detecção de compostos orgânicos voláteis e umidade relativa. 2012. 192 f. Tese (Doutorado em Multidisciplinar) - Universidade Federal de São Carlos, São Carlos, 2012.
url https://repositorio.ufscar.br/handle/ufscar/259
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv bc47636f-2f51-4b82-91f7-484701cb0784
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Biotecnologia - PPGBiotec
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/259/1/4784.pdf
https://repositorio.ufscar.br/bitstream/ufscar/259/2/4784.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/259/3/4784.pdf.jpg
bitstream.checksum.fl_str_mv d4efe41cda16378eef382581c4b2c468
b399fcb8d509f4a228a045b142e4736c
3985f206ad123e4abd737a6d45ae7c92
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136243375439872