Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?

Detalhes bibliográficos
Autor(a) principal: Sakaguchi, Camila Akemi
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/8790
Resumo: Introduction: The 6-minute walk test (6MWT) is one of the most frequently employed among the submaximal exercise capacity tests, with a limited use in clinical practice due to its requirement for a large physical space. Therefore, a virtual reality-assisted 6- Minute Stationary March Test (6MSMT-VR) is proposed as a modern and alternative tool for exercise capacity assessment in small-sized environments. Objectives: To compare and correlate physiological variables, energy expenditure (EE) and number of steps (NS) between the 6MWT and the 6MSMT-VR, using the first one as the standard. Methods: Apparently healthy subjects, aged 18 to 60 years old, were assessed by physical examination, spirometry, tested for physical activity level and later grouped as active (A) or non-active (NA). They, then, performed each test twice and answered a self-tailored satisfaction survey. Each result obtained was later compared and correlated. Results: In spite of the significant difference in NS between tests (p<0.001), a positive correlation (r=0.50) was found between them. A positive correlation was also found between the NS in the 6MSMT-VR and the total distance (TD) in the 6MWT (r=0.48) and for every other correlation value in the NA group. The EE, nevertheless, had a positive correlation value only for A group (r=0.40). No significant differences were obtained for hemodynamic variables and dyspnea, albeit the majority of patients (55%) reported greater Lower Limb Fatigue in the 6MSMT-VR. Conclusion: The 6MSMT-VR was well tolerated by the study’s population and may, thus, be considered an alternative to the 6MWT.
id SCAR_9def215d87211c74ed475e721782e444
oai_identifier_str oai:repositorio.ufscar.br:ufscar/8790
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Sakaguchi, Camila AkemiJamami, Mauríciohttp://lattes.cnpq.br/4274129560250050http://lattes.cnpq.br/21751515087335503facb7e6-5878-49a0-97a9-14c473ad61b62017-05-31T13:37:39Z2017-05-31T13:37:39Z2016-02-26SAKAGUCHI, Camila Akemi. Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?. 2016. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2016. Disponível em: https://repositorio.ufscar.br/handle/ufscar/8790.https://repositorio.ufscar.br/handle/ufscar/8790Introduction: The 6-minute walk test (6MWT) is one of the most frequently employed among the submaximal exercise capacity tests, with a limited use in clinical practice due to its requirement for a large physical space. Therefore, a virtual reality-assisted 6- Minute Stationary March Test (6MSMT-VR) is proposed as a modern and alternative tool for exercise capacity assessment in small-sized environments. Objectives: To compare and correlate physiological variables, energy expenditure (EE) and number of steps (NS) between the 6MWT and the 6MSMT-VR, using the first one as the standard. Methods: Apparently healthy subjects, aged 18 to 60 years old, were assessed by physical examination, spirometry, tested for physical activity level and later grouped as active (A) or non-active (NA). They, then, performed each test twice and answered a self-tailored satisfaction survey. Each result obtained was later compared and correlated. Results: In spite of the significant difference in NS between tests (p<0.001), a positive correlation (r=0.50) was found between them. A positive correlation was also found between the NS in the 6MSMT-VR and the total distance (TD) in the 6MWT (r=0.48) and for every other correlation value in the NA group. The EE, nevertheless, had a positive correlation value only for A group (r=0.40). No significant differences were obtained for hemodynamic variables and dyspnea, albeit the majority of patients (55%) reported greater Lower Limb Fatigue in the 6MSMT-VR. Conclusion: The 6MSMT-VR was well tolerated by the study’s population and may, thus, be considered an alternative to the 6MWT.O objetivo deste estudo foi propor uma nova ferramenta de avaliação da capacidade ao exercício segura, atual, incentivadora e otimizadora de espaços, através da comparação e correlação entre as variáveis de Número de Passos (NP), Gasto Energético (GE), Frequência Cardíaca (FC), Saturação periférica de Oxigênio (SpO2), Pressão Arterial Sistólica (PAS) e Diastólica (PAD), sensação de dispneia e fadiga de Membros Inferiores (MMII) de um Teste de Marcha Estacionária de Seis minutos com o incentivo de um dispositivo de Realidade Virtual (TME6-RV) com as de um Teste de Caminhada de seis minutos (TC6), e ainda, com a sua distância percorrida. Métodos: Sessenta indivíduos aparentemente saudáveis com idade média de 36,8 ± 12 anos, foram divididos em dois grupos: Ativos (A) e Não Ativos (NA). Foram realizadas avaliações antropométricas e espirometria, e então executados por duas vezes o TC6 e o TME6-RV em dias diferentes. Ao final, responderam à um questionário de Preferência e Satisfação nos testes. Resultados: Apesar da diferença significativa no NP nos dois testes (p=0,00), houve correlação entre eles (r=0,496), do NP no TME6-RV com a Distância Percorrida no TC6 (DTC6) (r= 0,485) e nas demais correlações no grupo dos Não Ativos (NA). Houve diferença no GE (p=0,00) e a correlação ocorreu no grupo dos Ativos (A) (r= 0,396). Não houve diferenças clinicamente relevantes nas alterações fisiológicas, porém, a maior parte dos voluntários (55%) relatou mais fadiga nas pernas no TME6-RV e a maioria não diferiu quanto à dispneia. 88% dos voluntários classificaram o TME6-RV como um teste “descontraído e interessante”. Conclusão: O TME6 com o uso da Realidade Virtual é um recurso atual e incentivador apresentando correlação com o TC6 em grande parte das variáveis, podendo ser utilizado como alternativa para avaliação da capacidade ao exercício para a população do estudo.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)porUniversidade Federal de São CarlosCâmpus São CarlosPrograma de Pós-Graduação em Fisioterapia - PPGFtUFSCarTeste de esforçoMembro inferiorAvaliação em saúdeCIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONALTeste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?Virtual reality assisted 6- minute stationary march test : a new alternative to the 6-minute walk test?info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisOnline600600bd0cbb98-978e-41d4-acd9-a1acaba0dedainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINALDissCAS.pdfDissCAS.pdfapplication/pdf2315381https://repositorio.ufscar.br/bitstream/ufscar/8790/1/DissCAS.pdf4248d101ce06c2ce717c8d0211bb3369MD51TEXTDissCAS.pdf.txtDissCAS.pdf.txtExtracted texttext/plain82026https://repositorio.ufscar.br/bitstream/ufscar/8790/2/DissCAS.pdf.txt51a047efed9a6779738091a25f64fce4MD52THUMBNAILDissCAS.pdf.jpgDissCAS.pdf.jpgIM Thumbnailimage/jpeg5812https://repositorio.ufscar.br/bitstream/ufscar/8790/3/DissCAS.pdf.jpg2346438fa5972809bbeb50b1c45faf74MD53ufscar/87902023-09-18 18:31:24.158oai:repositorio.ufscar.br:ufscar/8790Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:24Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
dc.title.alternative.eng.fl_str_mv Virtual reality assisted 6- minute stationary march test : a new alternative to the 6-minute walk test?
title Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
spellingShingle Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
Sakaguchi, Camila Akemi
Teste de esforço
Membro inferior
Avaliação em saúde
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
title_short Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
title_full Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
title_fullStr Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
title_full_unstemmed Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
title_sort Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?
author Sakaguchi, Camila Akemi
author_facet Sakaguchi, Camila Akemi
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/2175151508733550
dc.contributor.author.fl_str_mv Sakaguchi, Camila Akemi
dc.contributor.advisor1.fl_str_mv Jamami, Maurício
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/4274129560250050
dc.contributor.authorID.fl_str_mv 3facb7e6-5878-49a0-97a9-14c473ad61b6
contributor_str_mv Jamami, Maurício
dc.subject.por.fl_str_mv Teste de esforço
Membro inferior
Avaliação em saúde
topic Teste de esforço
Membro inferior
Avaliação em saúde
CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
description Introduction: The 6-minute walk test (6MWT) is one of the most frequently employed among the submaximal exercise capacity tests, with a limited use in clinical practice due to its requirement for a large physical space. Therefore, a virtual reality-assisted 6- Minute Stationary March Test (6MSMT-VR) is proposed as a modern and alternative tool for exercise capacity assessment in small-sized environments. Objectives: To compare and correlate physiological variables, energy expenditure (EE) and number of steps (NS) between the 6MWT and the 6MSMT-VR, using the first one as the standard. Methods: Apparently healthy subjects, aged 18 to 60 years old, were assessed by physical examination, spirometry, tested for physical activity level and later grouped as active (A) or non-active (NA). They, then, performed each test twice and answered a self-tailored satisfaction survey. Each result obtained was later compared and correlated. Results: In spite of the significant difference in NS between tests (p<0.001), a positive correlation (r=0.50) was found between them. A positive correlation was also found between the NS in the 6MSMT-VR and the total distance (TD) in the 6MWT (r=0.48) and for every other correlation value in the NA group. The EE, nevertheless, had a positive correlation value only for A group (r=0.40). No significant differences were obtained for hemodynamic variables and dyspnea, albeit the majority of patients (55%) reported greater Lower Limb Fatigue in the 6MSMT-VR. Conclusion: The 6MSMT-VR was well tolerated by the study’s population and may, thus, be considered an alternative to the 6MWT.
publishDate 2016
dc.date.issued.fl_str_mv 2016-02-26
dc.date.accessioned.fl_str_mv 2017-05-31T13:37:39Z
dc.date.available.fl_str_mv 2017-05-31T13:37:39Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SAKAGUCHI, Camila Akemi. Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?. 2016. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2016. Disponível em: https://repositorio.ufscar.br/handle/ufscar/8790.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/8790
identifier_str_mv SAKAGUCHI, Camila Akemi. Teste de marcha estacionária de seis minutos com uso de dispositivo de realidade virtual : uma alternativa ao teste de caminhada de seis minutos?. 2016. Dissertação (Mestrado em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2016. Disponível em: https://repositorio.ufscar.br/handle/ufscar/8790.
url https://repositorio.ufscar.br/handle/ufscar/8790
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv 600
600
dc.relation.authority.fl_str_mv bd0cbb98-978e-41d4-acd9-a1acaba0deda
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Fisioterapia - PPGFt
dc.publisher.initials.fl_str_mv UFSCar
publisher.none.fl_str_mv Universidade Federal de São Carlos
Câmpus São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/8790/1/DissCAS.pdf
https://repositorio.ufscar.br/bitstream/ufscar/8790/2/DissCAS.pdf.txt
https://repositorio.ufscar.br/bitstream/ufscar/8790/3/DissCAS.pdf.jpg
bitstream.checksum.fl_str_mv 4248d101ce06c2ce717c8d0211bb3369
51a047efed9a6779738091a25f64fce4
2346438fa5972809bbeb50b1c45faf74
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1813715575614996480