Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil

Detalhes bibliográficos
Autor(a) principal: Santos, Vagner Bezerra dos
Data de Publicação: 2009
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFSCAR
Texto Completo: https://repositorio.ufscar.br/handle/ufscar/6450
Resumo: Development of a portable, simple and inexpensive equipment with adequate sensitivity for turbidimetric and/or nephelometric sequential analyses practically simultaneous is the aim of this study. In fact, in-situ and on-line analysis of chemical substances of interest (analytes) can be accomplished. This is requested mainly in situations in which the place is difficult to access or even in circumstances in which the physical- chemical characteristics of the samples should be unchanged. Thus, the equipment was applied in- situ sulfate determination in lake samples. Analytes of interest such as N-acetylcysteine, captopril and thiamine in pharmaceutical samples and potassium in isotonic beverages were also analyzed with the developed instrumentation. The PMTN (Portable Microcontrolled Turbidimeter Nephelometer) is made of LEDs (Light Emitting Diodes) as radiation sources, phototransistors as optical sensors and a PIC microcontroller (Peripherical Interface Controller) as processing unit for control and data acquisition. The PMTN was tested and calibrated properly according to the norms establish by ISO 7027 for equipment base on LEDs as radiation source. The PMTN was applied to determine the concentration of analytes and compared with the reference or validated methods for each analyte, as described in the literature. In general, results agreed at the 95% confidence level were obtained. The detection limits and quantification for the determination of the several analytes were agreed with in some better cases than those found in the literature. On average, the PMTN furnished two decades of linear range of concentration and a reproducibility (RSD) lower than 3.0 % with an average error of less than 5.0 % were also obtained.
id SCAR_b5016363d9bcef65e0b82371dd9b1013
oai_identifier_str oai:repositorio.ufscar.br:ufscar/6450
network_acronym_str SCAR
network_name_str Repositório Institucional da UFSCAR
repository_id_str 4322
spelling Santos, Vagner Bezerra dosFatibello Filho, OrlandoÚltima atualização do currículo em 14/03/2011http://lattes.cnpq.br/5690211284729828c29d66b8-a5d2-4944-84e8-09ee9a9a85f12016-06-02T20:36:22Z2009-11-182016-06-02T20:36:22Z2009-07-30SANTOS, Vagner Bezerra dos. Construction and application of a portable microcontrolled turbidimeter nephelometer. 2009. 142 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2009.https://repositorio.ufscar.br/handle/ufscar/6450Development of a portable, simple and inexpensive equipment with adequate sensitivity for turbidimetric and/or nephelometric sequential analyses practically simultaneous is the aim of this study. In fact, in-situ and on-line analysis of chemical substances of interest (analytes) can be accomplished. This is requested mainly in situations in which the place is difficult to access or even in circumstances in which the physical- chemical characteristics of the samples should be unchanged. Thus, the equipment was applied in- situ sulfate determination in lake samples. Analytes of interest such as N-acetylcysteine, captopril and thiamine in pharmaceutical samples and potassium in isotonic beverages were also analyzed with the developed instrumentation. The PMTN (Portable Microcontrolled Turbidimeter Nephelometer) is made of LEDs (Light Emitting Diodes) as radiation sources, phototransistors as optical sensors and a PIC microcontroller (Peripherical Interface Controller) as processing unit for control and data acquisition. The PMTN was tested and calibrated properly according to the norms establish by ISO 7027 for equipment base on LEDs as radiation source. The PMTN was applied to determine the concentration of analytes and compared with the reference or validated methods for each analyte, as described in the literature. In general, results agreed at the 95% confidence level were obtained. The detection limits and quantification for the determination of the several analytes were agreed with in some better cases than those found in the literature. On average, the PMTN furnished two decades of linear range of concentration and a reproducibility (RSD) lower than 3.0 % with an average error of less than 5.0 % were also obtained.A necessidade de um equipamento portátil, simples, de baixo custo e com boa sensibilidade para análises turbidimétricas e/ou nefelométricas de modo praticamente simultâneo motivou o desenvolvimento da presente dissertação de mestrado. Com esse equipamento, foi possível a realização de determinações de substâncias químicas de interesse (analitos) in-situ e em tempo real. Esse tipo de determinação é requerido principalmente em situações onde o deslocamento ao local é difícil, ou até mesmo, em circunstâncias nas quais as características físico-químicas das amostras devem ser rigorosamente inalteradas. Neste contexto, o equipamento foi aplicado na determinação de sulfato em águas de lago com análise em tempo real e no local de coleta. Analitos de interesse como Nacetilcisteína, captopril e tiamina em amostras farmacêuticas e potássio em bebidas também foram determinados com o emprego da instrumentação desenvolvida. O equipamento, intitulado PMTN (do inglês Portable Microcontrolled Turbidimeter Nephelometer), é composto principalmente por LEDs (do inglês Light Emitting Diodes), fototransistores como sensores ópticos e um microcontrolador PIC (Peripherical Interface Controller) como unidade de processamento, controle e aquisição de dados. O PMTN foi devidamente testado e calibrado conforme as normas exigidas pela ISO 7027 para equipamento à base de LEDs como fonte de radiação. Devidamente calibrado, o PMTN foi aplicado para determinações dos analitos supracitados e comparado com os métodos de referência ou métodos validados para cada analito descritos na literatura. Em todas as aplicações, os resultados obtidos empregando-se o equipamento foram concordantes a um nível de confiança de 95 %. Os limites de detecção e de quantificação para a determinação dos diversos analitos foram compatíveis e em alguns casos melhores que os encontrados na literatura. Em média duas décadas de faixa linear de concentração e uma reprodutibilidade (RSD) menor que 3,0 % com erros relativos em média menores que 5,0 % também foram obtidos.Financiadora de Estudos e Projetosapplication/pdfporUniversidade Federal de São CarlosPrograma de Pós-Graduação em Química - PPGQUFSCarBRAnálise fotométricaMicrocontroladorControladores programáveisTurbidezNefelometriaLEDCIENCIAS EXATAS E DA TERRA::QUIMICAConstrução e aplicação de um Turbidímetro / Nefelômetro Microcontrolado PortátilConstruction and application of a portable microcontrolled turbidimeter nephelometerinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-1-17a1dec22-4b2d-4dba-8971-ab07f55c7d54info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSCARinstname:Universidade Federal de São Carlos (UFSCAR)instacron:UFSCARORIGINAL2551.pdfapplication/pdf7371466https://repositorio.ufscar.br/bitstream/ufscar/6450/1/2551.pdf71ef99e7141b5664de0e2594fbac263aMD51THUMBNAIL2551.pdf.jpg2551.pdf.jpgIM Thumbnailimage/jpeg8942https://repositorio.ufscar.br/bitstream/ufscar/6450/2/2551.pdf.jpgd4e212a0308abde2cbe17b6574a6d9b5MD52ufscar/64502023-09-18 18:31:11.522oai:repositorio.ufscar.br:ufscar/6450Repositório InstitucionalPUBhttps://repositorio.ufscar.br/oai/requestopendoar:43222023-09-18T18:31:11Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)false
dc.title.por.fl_str_mv Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
dc.title.alternative.eng.fl_str_mv Construction and application of a portable microcontrolled turbidimeter nephelometer
title Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
spellingShingle Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
Santos, Vagner Bezerra dos
Análise fotométrica
Microcontrolador
Controladores programáveis
Turbidez
Nefelometria
LED
CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
title_full Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
title_fullStr Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
title_full_unstemmed Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
title_sort Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil
author Santos, Vagner Bezerra dos
author_facet Santos, Vagner Bezerra dos
author_role author
dc.contributor.authorlattes.por.fl_str_mv http://lattes.cnpq.br/5690211284729828
dc.contributor.author.fl_str_mv Santos, Vagner Bezerra dos
dc.contributor.advisor1.fl_str_mv Fatibello Filho, Orlando
dc.contributor.advisor1Lattes.fl_str_mv Última atualização do currículo em 14/03/2011
dc.contributor.authorID.fl_str_mv c29d66b8-a5d2-4944-84e8-09ee9a9a85f1
contributor_str_mv Fatibello Filho, Orlando
dc.subject.por.fl_str_mv Análise fotométrica
Microcontrolador
Controladores programáveis
Turbidez
Nefelometria
LED
topic Análise fotométrica
Microcontrolador
Controladores programáveis
Turbidez
Nefelometria
LED
CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::QUIMICA
description Development of a portable, simple and inexpensive equipment with adequate sensitivity for turbidimetric and/or nephelometric sequential analyses practically simultaneous is the aim of this study. In fact, in-situ and on-line analysis of chemical substances of interest (analytes) can be accomplished. This is requested mainly in situations in which the place is difficult to access or even in circumstances in which the physical- chemical characteristics of the samples should be unchanged. Thus, the equipment was applied in- situ sulfate determination in lake samples. Analytes of interest such as N-acetylcysteine, captopril and thiamine in pharmaceutical samples and potassium in isotonic beverages were also analyzed with the developed instrumentation. The PMTN (Portable Microcontrolled Turbidimeter Nephelometer) is made of LEDs (Light Emitting Diodes) as radiation sources, phototransistors as optical sensors and a PIC microcontroller (Peripherical Interface Controller) as processing unit for control and data acquisition. The PMTN was tested and calibrated properly according to the norms establish by ISO 7027 for equipment base on LEDs as radiation source. The PMTN was applied to determine the concentration of analytes and compared with the reference or validated methods for each analyte, as described in the literature. In general, results agreed at the 95% confidence level were obtained. The detection limits and quantification for the determination of the several analytes were agreed with in some better cases than those found in the literature. On average, the PMTN furnished two decades of linear range of concentration and a reproducibility (RSD) lower than 3.0 % with an average error of less than 5.0 % were also obtained.
publishDate 2009
dc.date.available.fl_str_mv 2009-11-18
2016-06-02T20:36:22Z
dc.date.issued.fl_str_mv 2009-07-30
dc.date.accessioned.fl_str_mv 2016-06-02T20:36:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SANTOS, Vagner Bezerra dos. Construction and application of a portable microcontrolled turbidimeter nephelometer. 2009. 142 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2009.
dc.identifier.uri.fl_str_mv https://repositorio.ufscar.br/handle/ufscar/6450
identifier_str_mv SANTOS, Vagner Bezerra dos. Construction and application of a portable microcontrolled turbidimeter nephelometer. 2009. 142 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de São Carlos, São Carlos, 2009.
url https://repositorio.ufscar.br/handle/ufscar/6450
dc.language.iso.fl_str_mv por
language por
dc.relation.confidence.fl_str_mv -1
-1
dc.relation.authority.fl_str_mv 7a1dec22-4b2d-4dba-8971-ab07f55c7d54
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química - PPGQ
dc.publisher.initials.fl_str_mv UFSCar
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de São Carlos
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSCAR
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:UFSCAR
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str UFSCAR
institution UFSCAR
reponame_str Repositório Institucional da UFSCAR
collection Repositório Institucional da UFSCAR
bitstream.url.fl_str_mv https://repositorio.ufscar.br/bitstream/ufscar/6450/1/2551.pdf
https://repositorio.ufscar.br/bitstream/ufscar/6450/2/2551.pdf.jpg
bitstream.checksum.fl_str_mv 71ef99e7141b5664de0e2594fbac263a
d4e212a0308abde2cbe17b6574a6d9b5
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSCAR - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv
_version_ 1802136295146782720