Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test

Detalhes bibliográficos
Autor(a) principal: Nóbrega,Andréa Martins da
Data de Publicação: 2012
Outros Autores: Alves,Eloisa Nunes, Presgrave,Rosaura de Farias, Costa,Rodrigo Netto, Delgado,Isabella Fernandes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Archives of Biology and Technology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132012000300008
Resumo: In an attempt to build the evaluation strategies to assess the human eye irritation, a reassessment of some in vitro tests is necessary, particularly concerning the non-irritants, mild and moderate irritants. Thus, the correlations between results obtained from the Draize test with the in vitro methods HET-CAM (Hens Egg Test-Chorion Allantonic Membrane) and RBC haemolysis assay to assess the ocular irritancy potential of 20 eye drops were examined. Parameters such as accuracy (%) and specificity (%) were determined. All results were correlated with RBC correctly with the results obtained in the Draize test. The HET-CAM presented four false-positive results, showing a tendency of data overestimation. Despite the high specificity provided mainly by the RBC, it would be necessary to test a wider range of products representing all the scales of irritation to confirm its ability to be used as a first alternative to test products that could be presumptive non-irritants.
id TECPAR-1_c09932038e3a149fa6786239cbbe29f4
oai_identifier_str oai:scielo:S1516-89132012000300008
network_acronym_str TECPAR-1
network_name_str Brazilian Archives of Biology and Technology
repository_id_str
spelling Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit testAlternative methodseye irritationDraize Testlow-irritantHET-CAMRBCIn an attempt to build the evaluation strategies to assess the human eye irritation, a reassessment of some in vitro tests is necessary, particularly concerning the non-irritants, mild and moderate irritants. Thus, the correlations between results obtained from the Draize test with the in vitro methods HET-CAM (Hens Egg Test-Chorion Allantonic Membrane) and RBC haemolysis assay to assess the ocular irritancy potential of 20 eye drops were examined. Parameters such as accuracy (%) and specificity (%) were determined. All results were correlated with RBC correctly with the results obtained in the Draize test. The HET-CAM presented four false-positive results, showing a tendency of data overestimation. Despite the high specificity provided mainly by the RBC, it would be necessary to test a wider range of products representing all the scales of irritation to confirm its ability to be used as a first alternative to test products that could be presumptive non-irritants.Instituto de Tecnologia do Paraná - Tecpar2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132012000300008Brazilian Archives of Biology and Technology v.55 n.3 2012reponame:Brazilian Archives of Biology and Technologyinstname:Instituto de Tecnologia do Paraná (Tecpar)instacron:TECPAR10.1590/S1516-89132012000300008info:eu-repo/semantics/openAccessNóbrega,Andréa Martins daAlves,Eloisa NunesPresgrave,Rosaura de FariasCosta,Rodrigo NettoDelgado,Isabella Fernandeseng2012-07-03T00:00:00Zoai:scielo:S1516-89132012000300008Revistahttps://www.scielo.br/j/babt/https://old.scielo.br/oai/scielo-oai.phpbabt@tecpar.br||babt@tecpar.br1678-43241516-8913opendoar:2012-07-03T00:00Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)false
dc.title.none.fl_str_mv Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
title Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
spellingShingle Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
Nóbrega,Andréa Martins da
Alternative methods
eye irritation
Draize Test
low-irritant
HET-CAM
RBC
title_short Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
title_full Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
title_fullStr Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
title_full_unstemmed Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
title_sort Determination of eye irritation potential of low-irritant products: comparison of in vitro results with the in vivo draize rabbit test
author Nóbrega,Andréa Martins da
author_facet Nóbrega,Andréa Martins da
Alves,Eloisa Nunes
Presgrave,Rosaura de Farias
Costa,Rodrigo Netto
Delgado,Isabella Fernandes
author_role author
author2 Alves,Eloisa Nunes
Presgrave,Rosaura de Farias
Costa,Rodrigo Netto
Delgado,Isabella Fernandes
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Nóbrega,Andréa Martins da
Alves,Eloisa Nunes
Presgrave,Rosaura de Farias
Costa,Rodrigo Netto
Delgado,Isabella Fernandes
dc.subject.por.fl_str_mv Alternative methods
eye irritation
Draize Test
low-irritant
HET-CAM
RBC
topic Alternative methods
eye irritation
Draize Test
low-irritant
HET-CAM
RBC
description In an attempt to build the evaluation strategies to assess the human eye irritation, a reassessment of some in vitro tests is necessary, particularly concerning the non-irritants, mild and moderate irritants. Thus, the correlations between results obtained from the Draize test with the in vitro methods HET-CAM (Hens Egg Test-Chorion Allantonic Membrane) and RBC haemolysis assay to assess the ocular irritancy potential of 20 eye drops were examined. Parameters such as accuracy (%) and specificity (%) were determined. All results were correlated with RBC correctly with the results obtained in the Draize test. The HET-CAM presented four false-positive results, showing a tendency of data overestimation. Despite the high specificity provided mainly by the RBC, it would be necessary to test a wider range of products representing all the scales of irritation to confirm its ability to be used as a first alternative to test products that could be presumptive non-irritants.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132012000300008
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132012000300008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1516-89132012000300008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
publisher.none.fl_str_mv Instituto de Tecnologia do Paraná - Tecpar
dc.source.none.fl_str_mv Brazilian Archives of Biology and Technology v.55 n.3 2012
reponame:Brazilian Archives of Biology and Technology
instname:Instituto de Tecnologia do Paraná (Tecpar)
instacron:TECPAR
instname_str Instituto de Tecnologia do Paraná (Tecpar)
instacron_str TECPAR
institution TECPAR
reponame_str Brazilian Archives of Biology and Technology
collection Brazilian Archives of Biology and Technology
repository.name.fl_str_mv Brazilian Archives of Biology and Technology - Instituto de Tecnologia do Paraná (Tecpar)
repository.mail.fl_str_mv babt@tecpar.br||babt@tecpar.br
_version_ 1750318275209723904