Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363

Detalhes bibliográficos
Autor(a) principal: Aquino, Jailane de Souza
Data de Publicação: 2009
Outros Autores: Salvino, Érica Menezes
Tipo de documento: Artigo
Idioma: por
Título da fonte: Acta scientiarum. Technology (Online)
Texto Completo: http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363
Resumo: The purpose of this study was to calculate the iron bioavailability and to evaluate the frequency of the mineral, that makes part of the institutional meals of a University Hospital’s restaurant. An algorithm was used to calculate the percentage of iron bioavailability in the four institutional meals. Institutional meal nº 2 presented the higher frequency of iron whereas the nº 3 presented the lowest. The highest mean of iron ingested was evidenced in nº 2, however the higher bioavailability was found in nº 3. The meals were present intermediary bioavailability and the menus demonstrated to be inadequate in its majority for pregnant women. It was possible to observe that it is not a matter of high frequency of iron that will result in a higher ingestion and absorption, because it is all related to its bioavailability in the meal.
id UEM-6_eecbc1f987c4b332c1f38878e3beb7f5
oai_identifier_str oai:periodicos.uem.br/ojs:article/363
network_acronym_str UEM-6
network_name_str Acta scientiarum. Technology (Online)
repository_id_str
spelling Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363Estimativa da porcentagem de biodisponibilidade e frequência de ferro nos cardápios do restaurante de um Hospital Universitário - DOI: 10.4025/actascitechnol.v31i1.363ferrobiodisponibilidadecardápiosThe purpose of this study was to calculate the iron bioavailability and to evaluate the frequency of the mineral, that makes part of the institutional meals of a University Hospital’s restaurant. An algorithm was used to calculate the percentage of iron bioavailability in the four institutional meals. Institutional meal nº 2 presented the higher frequency of iron whereas the nº 3 presented the lowest. The highest mean of iron ingested was evidenced in nº 2, however the higher bioavailability was found in nº 3. The meals were present intermediary bioavailability and the menus demonstrated to be inadequate in its majority for pregnant women. It was possible to observe that it is not a matter of high frequency of iron that will result in a higher ingestion and absorption, because it is all related to its bioavailability in the meal.O objetivo do presente estudo foi calcular a biodisponibilidade de ferro e avaliar a frequência deste mineral nos cardápios do restaurante de um Hospital Universitário. Um algoritmo foi utilizado para cálculo da porcentagem de ferro biodisponível em quatro cardápios. O cardápio nº 2 apresentou a maior frequência de ferro; o nº 3, a menor. A maior média de ferro ingerido foi a evidenciada no cardápio 2, com 19,93 mg de ferro, porém a maior biodisponibilidade foi encontrada no cardápio 3, com 1,79 mg de ferro. Tanto a quantidade de ferro ingerida quanto a biodisponível destes cardápios não apresentaram diferença significativa (p > 0,05), no entanto suas médias absolutas de biodisponibilidade foram influenciadas com maior intensidade pela presença de ácido ascórbico e tecidos animais, e menos pelas gorduras. As refeições apresentaram biodisponibilidade intermediária e os cardápios mostraram-se inadequados, em sua maioria, para gestantes. Pode-se observar que nem sempre a maior frequência de ferro resultará em maior ingestão e em maior absorção, pois tudo isso depende de sua biodisponibilidade na refeição.Universidade Estadual De Maringá2009-04-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/mswordhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/36310.4025/actascitechnol.v31i1.363Acta Scientiarum. Technology; Vol 31 No 1 (2009); 109-116Acta Scientiarum. Technology; v. 31 n. 1 (2009); 109-1161806-25631807-8664reponame:Acta scientiarum. Technology (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363/363http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363/751375140770Aquino, Jailane de SouzaSalvino, Érica Menezesinfo:eu-repo/semantics/openAccess2024-05-17T13:02:26Zoai:periodicos.uem.br/ojs:article/363Revistahttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/indexPUBhttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/oai||actatech@uem.br1807-86641806-2563opendoar:2024-05-17T13:02:26Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
Estimativa da porcentagem de biodisponibilidade e frequência de ferro nos cardápios do restaurante de um Hospital Universitário - DOI: 10.4025/actascitechnol.v31i1.363
title Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
spellingShingle Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
Aquino, Jailane de Souza
ferro
biodisponibilidade
cardápios
title_short Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
title_full Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
title_fullStr Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
title_full_unstemmed Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
title_sort Estimate of percentage of bioavailability and iron frequency in the menu of a university hospital restaurant - DOI: 10.4025/actascitechnol.v31i1.363
author Aquino, Jailane de Souza
author_facet Aquino, Jailane de Souza
Salvino, Érica Menezes
author_role author
author2 Salvino, Érica Menezes
author2_role author
dc.contributor.author.fl_str_mv Aquino, Jailane de Souza
Salvino, Érica Menezes
dc.subject.por.fl_str_mv ferro
biodisponibilidade
cardápios
topic ferro
biodisponibilidade
cardápios
description The purpose of this study was to calculate the iron bioavailability and to evaluate the frequency of the mineral, that makes part of the institutional meals of a University Hospital’s restaurant. An algorithm was used to calculate the percentage of iron bioavailability in the four institutional meals. Institutional meal nº 2 presented the higher frequency of iron whereas the nº 3 presented the lowest. The highest mean of iron ingested was evidenced in nº 2, however the higher bioavailability was found in nº 3. The meals were present intermediary bioavailability and the menus demonstrated to be inadequate in its majority for pregnant women. It was possible to observe that it is not a matter of high frequency of iron that will result in a higher ingestion and absorption, because it is all related to its bioavailability in the meal.
publishDate 2009
dc.date.none.fl_str_mv 2009-04-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363
10.4025/actascitechnol.v31i1.363
url http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363
identifier_str_mv 10.4025/actascitechnol.v31i1.363
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363/363
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/363/751375140770
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/msword
dc.publisher.none.fl_str_mv Universidade Estadual De Maringá
publisher.none.fl_str_mv Universidade Estadual De Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Technology; Vol 31 No 1 (2009); 109-116
Acta Scientiarum. Technology; v. 31 n. 1 (2009); 109-116
1806-2563
1807-8664
reponame:Acta scientiarum. Technology (Online)
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta scientiarum. Technology (Online)
collection Acta scientiarum. Technology (Online)
repository.name.fl_str_mv Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv ||actatech@uem.br
_version_ 1799315331440705536