Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems

Detalhes bibliográficos
Autor(a) principal: Albertini, Paolo
Data de Publicação: 2021
Outros Autores: Tremaroli, Matteo, Cremonini, Francesca, Palone, Mario
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
Texto Completo: https://revista.uepb.edu.br/PBOCI/article/view/572
Resumo: Objective: To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods:  The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models. Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results: Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively). However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion:  The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.
id UEPB-4_8dfdef6d24efae1a7e1947a038fbcabc
oai_identifier_str oai:ojs.pkp.sfu.ca:article/572
network_acronym_str UEPB-4
network_name_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository_id_str
spelling Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding SystemsOrthodonticsOrthodontic BracketsOrthodontics, CorrectiveObjective: To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods:  The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models. Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results: Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively). However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion:  The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA2021-10-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revista.uepb.edu.br/PBOCI/article/view/572Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 21 (2021); e210028Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 21 (2021); e2100281983-46321519-0501reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)instname:Universidade Estadual da Paraíba (UEPB)instacron:UEPBenghttps://revista.uepb.edu.br/PBOCI/article/view/572/300Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integradahttps://creativecommons.org/licenses/by-nc/4.0info:eu-repo/semantics/openAccessAlbertini, Paolo Tremaroli, Matteo Cremonini, Francesca Palone, Mario 2021-10-31T19:27:01Zoai:ojs.pkp.sfu.ca:article/572Revistahttps://revista.uepb.edu.br/PBOCI/PUBhttps://revista.uepb.edu.br/PBOCI/oaipboci.editoria@gmail.com || alessandrouepb@gmail.com1983-46321519-0501opendoar:2021-10-31T19:27:01Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)false
dc.title.none.fl_str_mv Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
title Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
spellingShingle Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
Albertini, Paolo
Orthodontics
Orthodontic Brackets
Orthodontics, Corrective
title_short Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
title_full Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
title_fullStr Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
title_full_unstemmed Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
title_sort Comparison of Bracket Position Accuracy with Different CAD/CAM Indirect Bonding Systems
author Albertini, Paolo
author_facet Albertini, Paolo
Tremaroli, Matteo
Cremonini, Francesca
Palone, Mario
author_role author
author2 Tremaroli, Matteo
Cremonini, Francesca
Palone, Mario
author2_role author
author
author
dc.contributor.author.fl_str_mv Albertini, Paolo
Tremaroli, Matteo
Cremonini, Francesca
Palone, Mario
dc.subject.por.fl_str_mv Orthodontics
Orthodontic Brackets
Orthodontics, Corrective
topic Orthodontics
Orthodontic Brackets
Orthodontics, Corrective
description Objective: To evaluate the accuracy of three different digital bracket positioning systems, comparing vertical, mesiodistal and buccolingual accuracy. Material and Methods:  The same case was sent to Orapix, Insignia, and Orthocad systems and the brackets were bonded to the malocclusion models. Damon 3 MX brackets were used with all systems and the brackets were bonded to the models with the same bonding protocol and materials. The comparison of the position of each single bracket was made with digital photography, and ImageJ software was used to find the length in pixels and then convert it to hundredths of a mm for vertical, mesiodistal and buccolingual displacement, compared to the setup. Results: Insignia System reported the average higher vertical displacement (0.28 mm), compared with the other two appliances (0.22-0.23 mm), and showed the lowest average displacement for the mesiodistal and buccolingual positioning (0.14 and 0.07 mm, respectively). However, these slight bracket positioning variations between these bonding systems were not statistically different (p>0.05). Conclusion:  The three systems analyzed were shown to be accurate in positioning the brackets, and none of them was statistically better.
publishDate 2021
dc.date.none.fl_str_mv 2021-10-31
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/572
url https://revista.uepb.edu.br/PBOCI/article/view/572
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/572/300
dc.rights.driver.fl_str_mv Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
dc.source.none.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 21 (2021); e210028
Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 21 (2021); e210028
1983-4632
1519-0501
reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
instname:Universidade Estadual da Paraíba (UEPB)
instacron:UEPB
instname_str Universidade Estadual da Paraíba (UEPB)
instacron_str UEPB
institution UEPB
reponame_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
collection Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository.name.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)
repository.mail.fl_str_mv pboci.editoria@gmail.com || alessandrouepb@gmail.com
_version_ 1803387862283976704