Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles

Detalhes bibliográficos
Autor(a) principal: Ribeiro, Caroline Santos
Data de Publicação: 2021
Outros Autores: Perez, Mayra Manoella, Benitez-Sellan, Pablo Lenin, Guaré, Renata de Oliveira, Bresciani, Eduardo, Diniz, Michele Baffi
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
Texto Completo: https://revista.uepb.edu.br/PBOCI/article/view/660
Resumo: Objective: To determine the initial mechanical stabilization of conventional glass ionomer cements (GICs) indicated for the atraumatic restorative treatment (ART) in different storage periods. Material and Methods: Specimens were divided according to the GIC (n=12): IZ - Ion-Z, KM - Ketac Molar Easymix, RS - Riva Self Cure, and GL - Gold Label 9. They were prepared and stored in distilled water. Superficial microhardness (SMH) was evaluated (KHN) in three phases: (A) after 1, (B) 3, and (C) 7 days of storage. Data were submitted to 2-way ANOVA and Tukey tests (α = 5%). Results: The average KHN values for phases A, B, and C were, respectively, 33.05 ± 9.74; 33.21 ± 10.31 and 52.07 ± 11.75 (IZ); 50.35 ± 11.39; 66.05 ± 10.48 and 67.77 ± 13.80 (KM); 89.63 ± 15.59; 71.31 ± 23.86 and 57.70 ± 16.89 (RS); 42.18 ± 9.03; 68.54 ± 6.83 and 57.95 ± 8.24 (GL). Significant differences were observed: GIC, time, and interaction of both (p<0.05). KHN values differed between the groups, except in the GIC parameter for KM and GL. The time parameter values of phase A were lower than those of B and C, except for IZ and RS. Conclusion: The initial mechanical stabilization differed between the types of GIC tested and the storage time, and after the final period, all had similar SMH.
id UEPB-4_d7452763ec107e03f8106d7933019e37
oai_identifier_str oai:ojs.pkp.sfu.ca:article/660
network_acronym_str UEPB-4
network_name_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository_id_str
spelling Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active PrinciplesDental CementsGlass Ionomer CementsHardness TestsZincObjective: To determine the initial mechanical stabilization of conventional glass ionomer cements (GICs) indicated for the atraumatic restorative treatment (ART) in different storage periods. Material and Methods: Specimens were divided according to the GIC (n=12): IZ - Ion-Z, KM - Ketac Molar Easymix, RS - Riva Self Cure, and GL - Gold Label 9. They were prepared and stored in distilled water. Superficial microhardness (SMH) was evaluated (KHN) in three phases: (A) after 1, (B) 3, and (C) 7 days of storage. Data were submitted to 2-way ANOVA and Tukey tests (α = 5%). Results: The average KHN values for phases A, B, and C were, respectively, 33.05 ± 9.74; 33.21 ± 10.31 and 52.07 ± 11.75 (IZ); 50.35 ± 11.39; 66.05 ± 10.48 and 67.77 ± 13.80 (KM); 89.63 ± 15.59; 71.31 ± 23.86 and 57.70 ± 16.89 (RS); 42.18 ± 9.03; 68.54 ± 6.83 and 57.95 ± 8.24 (GL). Significant differences were observed: GIC, time, and interaction of both (p<0.05). KHN values differed between the groups, except in the GIC parameter for KM and GL. The time parameter values of phase A were lower than those of B and C, except for IZ and RS. Conclusion: The initial mechanical stabilization differed between the types of GIC tested and the storage time, and after the final period, all had similar SMH.EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA2021-11-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revista.uepb.edu.br/PBOCI/article/view/660Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 21 (2021); e0096Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 21 (2021); e00961983-46321519-0501reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)instname:Universidade Estadual da Paraíba (UEPB)instacron:UEPBenghttps://revista.uepb.edu.br/PBOCI/article/view/660/355Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integradahttps://creativecommons.org/licenses/by-nc/4.0info:eu-repo/semantics/openAccessRibeiro, Caroline Santos Perez, Mayra Manoella Benitez-Sellan, Pablo Lenin Guaré, Renata de Oliveira Bresciani, Eduardo Diniz, Michele Baffi 2021-11-12T21:54:20Zoai:ojs.pkp.sfu.ca:article/660Revistahttps://revista.uepb.edu.br/PBOCI/PUBhttps://revista.uepb.edu.br/PBOCI/oaipboci.editoria@gmail.com || alessandrouepb@gmail.com1983-46321519-0501opendoar:2021-11-12T21:54:20Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)false
dc.title.none.fl_str_mv Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
title Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
spellingShingle Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
Ribeiro, Caroline Santos
Dental Cements
Glass Ionomer Cements
Hardness Tests
Zinc
title_short Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
title_full Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
title_fullStr Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
title_full_unstemmed Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
title_sort Initial Mechanical Stabilization of Conventional Glass Ionomer Cements with Different Active Principles
author Ribeiro, Caroline Santos
author_facet Ribeiro, Caroline Santos
Perez, Mayra Manoella
Benitez-Sellan, Pablo Lenin
Guaré, Renata de Oliveira
Bresciani, Eduardo
Diniz, Michele Baffi
author_role author
author2 Perez, Mayra Manoella
Benitez-Sellan, Pablo Lenin
Guaré, Renata de Oliveira
Bresciani, Eduardo
Diniz, Michele Baffi
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ribeiro, Caroline Santos
Perez, Mayra Manoella
Benitez-Sellan, Pablo Lenin
Guaré, Renata de Oliveira
Bresciani, Eduardo
Diniz, Michele Baffi
dc.subject.por.fl_str_mv Dental Cements
Glass Ionomer Cements
Hardness Tests
Zinc
topic Dental Cements
Glass Ionomer Cements
Hardness Tests
Zinc
description Objective: To determine the initial mechanical stabilization of conventional glass ionomer cements (GICs) indicated for the atraumatic restorative treatment (ART) in different storage periods. Material and Methods: Specimens were divided according to the GIC (n=12): IZ - Ion-Z, KM - Ketac Molar Easymix, RS - Riva Self Cure, and GL - Gold Label 9. They were prepared and stored in distilled water. Superficial microhardness (SMH) was evaluated (KHN) in three phases: (A) after 1, (B) 3, and (C) 7 days of storage. Data were submitted to 2-way ANOVA and Tukey tests (α = 5%). Results: The average KHN values for phases A, B, and C were, respectively, 33.05 ± 9.74; 33.21 ± 10.31 and 52.07 ± 11.75 (IZ); 50.35 ± 11.39; 66.05 ± 10.48 and 67.77 ± 13.80 (KM); 89.63 ± 15.59; 71.31 ± 23.86 and 57.70 ± 16.89 (RS); 42.18 ± 9.03; 68.54 ± 6.83 and 57.95 ± 8.24 (GL). Significant differences were observed: GIC, time, and interaction of both (p<0.05). KHN values differed between the groups, except in the GIC parameter for KM and GL. The time parameter values of phase A were lower than those of B and C, except for IZ and RS. Conclusion: The initial mechanical stabilization differed between the types of GIC tested and the storage time, and after the final period, all had similar SMH.
publishDate 2021
dc.date.none.fl_str_mv 2021-11-12
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/660
url https://revista.uepb.edu.br/PBOCI/article/view/660
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revista.uepb.edu.br/PBOCI/article/view/660/355
dc.rights.driver.fl_str_mv Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Pesquisa Brasileira em Odontopediatria e Clínica Integrada
https://creativecommons.org/licenses/by-nc/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
publisher.none.fl_str_mv EDUEPB - EDITORA DA UNIVERSIDADE ESTADUAL DA PARAÍBA
dc.source.none.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada; Vol. 21 (2021); e0096
Pesquisa Brasileira em Odontopediatria e Clínica Integrada; v. 21 (2021); e0096
1983-4632
1519-0501
reponame:Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
instname:Universidade Estadual da Paraíba (UEPB)
instacron:UEPB
instname_str Universidade Estadual da Paraíba (UEPB)
instacron_str UEPB
institution UEPB
reponame_str Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
collection Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online)
repository.name.fl_str_mv Pesquisa Brasileira em Odontopediatria e Clínica Integrada (Online) - Universidade Estadual da Paraíba (UEPB)
repository.mail.fl_str_mv pboci.editoria@gmail.com || alessandrouepb@gmail.com
_version_ 1803387862375202816