AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da UEPG |
Texto Completo: | http://tede2.uepg.br/jspui/handle/prefix/1821 |
Resumo: | The aim of this work were investigate the microtensile bond strength (μTBS), nanoleakage (NL), nano-hardness (NH) and Young’s modulus (YM) of resin-dentin bonding components produced by two simplified etch-and-rinse adhesive with different concentrations of chlorhexidine diacetate (CHX). 99.9% of CHX were added to Ambar (FGM) and XP Bond (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. Resin-dentin bonded sticks (0.8 mm2) were prepared for μTBS testing (0.5 mm/min). For NL, some bonded sticks from each tooth were used. Nano-indentations were made on the adhesive interface and NH and YM calculated. The results of μTBS, NL and NH and YM of the hybrid layers of the CHX-free and CHX-containing adhesives were statistically similar (p > 0.05) on immediately time. After 12 months, significant reductions of μTBS were observed for both adhesives in the control group (p< 0.05). In CHX-containing adhesives or CHX-free groups the BS remained stable for both systems. NL was more evident in the control than in the experimental groups (p < 0.05) both in IM and 12 months periods. Conclusions: CHX in concentrations lower than 0.1 wt% incorporated in the two simplified etch-and-rinse adhesives did not impair the immediate resin-dentin bond strength, nanoleakage and mechanical properties of the adhesive and hybrid layers. |
id |
UEPG_951d9a2b6814a3d8a814dd0c5047d62f |
---|---|
oai_identifier_str |
oai:tede2.uepg.br:prefix/1821 |
network_acronym_str |
UEPG |
network_name_str |
Biblioteca Digital de Teses e Dissertações da UEPG |
repository_id_str |
|
spelling |
Loguércio, Alessandro DouradoCPF:38196913249http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4763905J5Farago, Paulo VitorCPF:02688357999Calixto, Abraham LincolnCPF:09610436870http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4769030H2Sabóia, Vicente de Paulo AragãoCPF:20831579931http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4706275E6Assad, Roberley AraújoCPF:76308871915http://lattes.cnpq.br/4862055266860370CPF:00540060909http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4771298P1Grande, Rodrigo Stanislawczuk2017-07-24T19:22:28Z2013-08-212017-07-24T19:22:28Z2012-11-30GRANDE, Rodrigo Stanislawczuk. Evaluation of diacetate chlorhexidine-containing adhesives. 2012. 160 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2012.http://tede2.uepg.br/jspui/handle/prefix/1821The aim of this work were investigate the microtensile bond strength (μTBS), nanoleakage (NL), nano-hardness (NH) and Young’s modulus (YM) of resin-dentin bonding components produced by two simplified etch-and-rinse adhesive with different concentrations of chlorhexidine diacetate (CHX). 99.9% of CHX were added to Ambar (FGM) and XP Bond (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. Resin-dentin bonded sticks (0.8 mm2) were prepared for μTBS testing (0.5 mm/min). For NL, some bonded sticks from each tooth were used. Nano-indentations were made on the adhesive interface and NH and YM calculated. The results of μTBS, NL and NH and YM of the hybrid layers of the CHX-free and CHX-containing adhesives were statistically similar (p > 0.05) on immediately time. After 12 months, significant reductions of μTBS were observed for both adhesives in the control group (p< 0.05). In CHX-containing adhesives or CHX-free groups the BS remained stable for both systems. NL was more evident in the control than in the experimental groups (p < 0.05) both in IM and 12 months periods. Conclusions: CHX in concentrations lower than 0.1 wt% incorporated in the two simplified etch-and-rinse adhesives did not impair the immediate resin-dentin bond strength, nanoleakage and mechanical properties of the adhesive and hybrid layers.O efeito da clorexidina (CHX) como agente para preservar a união tem sido bem estabelecido, mas pouco se sabe sobre a inclusão da CHX nos sistemas adesivos convencionais simplificados. Objetivos: 1) avaliar no tempo imediato o efeito da adição de diferentes concentrações de clorexidina (CHX 0,01%, 0,05%, 0,1% e 0,2%) em dois adesivos simplificados Ambar (AM) e XP Bond (XP) nas propriedades adesivas (resistência de união [RU] e nanoinfiltração [NI]) e físicas (nanoindentação [NP] e módulo de elasticidade [ME]) à dentina (experimento 1); 2) avaliar ao longo de doze meses o efeito da adição da CHX no AM e XP nas propriedades adesivas (resistência de união [RU] e nanoinfiltração [NI]) à dentina (experimento 2); 3) avaliar ao longo de 28 dias a adição de CHX no AM e XP nas características de sorção (SA), solubilidade (SO) e a liberação de clorexidina em água (experimento 3). Metodologia: para o experimento 1 e 2 foram utilizados molares humanos até a exposição da dentina oclusal. Os dentes foram divididos de acordo com as diferentes concentrações de clorexidina e tempo de armazenamento: sem CHX (controle); com 0,01%; 0,05%; 0,1%; e 0,2% de diacetato de CHX, testados imediatamente e ao longo de 12 meses. Após aplicação dos adesivos AM e XP, restaurações de resina composta foram realizadas. Cada dente foi cortado para obtenção de “palitos” que foram divididos de acordo com as propriedades a serem testadas e o tempo de armazenamento. Para RU, os palitos foram testados em tração (0,5mm/min). Para NP e ME foram testados em um nanodurômetro e para o teste de NI, os “palitos” foram corados com nitrato de prata e avaliados através de EDS em MEV. Para cada teste foi aplicada a análise estatística apropriada. Para o experimento 3 foram confeccionados espécimes na forma de discos e posterior verificação da sorção, solubilidade e doação de CHX. As mesmas concentrações de adesivos foram utilizadas. Para SA e SO, os espécimes após fotoativação foram desidratados (m1) e armazenados em água durante28 dias para avaliação gravimétrica úmida (m2) e após nova desidratação (m3) da sorção (m2 m3/volume) e solubilidade (m1-m3/volume). Resultados: A inclusão de diferentes concentrações de CHX não afetou as propriedades adesivas e físicas dos adesivos testados (experimento 1). Nos grupos controles dos dois adesivos testados (AM e XP), ocorreu degradação da resistência de união e aumento da quantidade de nitrato de prata após 12 meses de armazenamento em água, fato este que não ocorreu quando a CHX foi adicionada, independente da concentração (experimento 2). A adição de CHX não afetou a SA e SO, quando comparado com os respectivos grupos controle. Ocorreu liberação de CHX por todo o período do experimento, sendo maior nas primeiras 24 h (experimento 3). Conclusão: a incorporação de CHX ao adesivo não afetou de maneira imediata as propriedades adesivas e físicas de união a dentina, nem a sorção e solubilidade, mas preservou a união ao longo de 12 meses, além de liberar clorexidina por todo o período avaliado.Made available in DSpace on 2017-07-24T19:22:28Z (GMT). No. of bitstreams: 1 RODRIGO S GRANDE.pdf: 5650250 bytes, checksum: 965396f452f58590edf14d60a01a07f9 (MD5) Previous issue date: 2012-11-30application/pdfporUNIVERSIDADE ESTADUAL DE PONTA GROSSAPrograma de Pós-Graduação em OdontologiaUEPGBRClinica Integrada, Dentística Restauradora e PeriodontiaadesivoClorexidinaresistência de uniãodentinaadhesiveChlorhexidinebond-strengthdentinCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAAVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINAEvaluation of diacetate chlorhexidine-containing adhesivesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UEPGinstname:Universidade Estadual de Ponta Grossa (UEPG)instacron:UEPGORIGINALRODRIGO S GRANDE.pdfapplication/pdf5650250http://tede2.uepg.br/jspui/bitstream/prefix/1821/1/RODRIGO%20S%20GRANDE.pdf965396f452f58590edf14d60a01a07f9MD51prefix/18212017-07-24 16:22:28.742oai:tede2.uepg.br:prefix/1821Biblioteca Digital de Teses e Dissertaçõeshttps://tede2.uepg.br/jspui/PUBhttp://tede2.uepg.br/oai/requestbicen@uepg.br||mv_fidelis@yahoo.com.bropendoar:2017-07-24T19:22:28Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG)false |
dc.title.por.fl_str_mv |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
dc.title.alternative.eng.fl_str_mv |
Evaluation of diacetate chlorhexidine-containing adhesives |
title |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
spellingShingle |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA Grande, Rodrigo Stanislawczuk adesivo Clorexidina resistência de união dentina adhesive Chlorhexidine bond-strength dentin CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
title_short |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
title_full |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
title_fullStr |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
title_full_unstemmed |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
title_sort |
AVALIAÇÃO DE SISTEMAS ADESIVOS MODIFICADOS POR DIACETATO DE CLOREXIDINA |
author |
Grande, Rodrigo Stanislawczuk |
author_facet |
Grande, Rodrigo Stanislawczuk |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Loguércio, Alessandro Dourado |
dc.contributor.advisor1ID.fl_str_mv |
CPF:38196913249 |
dc.contributor.advisor1Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4763905J5 |
dc.contributor.advisor-co1.fl_str_mv |
Farago, Paulo Vitor |
dc.contributor.advisor-co1ID.fl_str_mv |
CPF:02688357999 |
dc.contributor.referee1.fl_str_mv |
Calixto, Abraham Lincoln |
dc.contributor.referee1ID.fl_str_mv |
CPF:09610436870 |
dc.contributor.referee1Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4769030H2 |
dc.contributor.referee2.fl_str_mv |
Sabóia, Vicente de Paulo Aragão |
dc.contributor.referee2ID.fl_str_mv |
CPF:20831579931 |
dc.contributor.referee2Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4706275E6 |
dc.contributor.referee3.fl_str_mv |
Assad, Roberley Araújo |
dc.contributor.referee3ID.fl_str_mv |
CPF:76308871915 |
dc.contributor.referee3Lattes.fl_str_mv |
http://lattes.cnpq.br/4862055266860370 |
dc.contributor.authorID.fl_str_mv |
CPF:00540060909 |
dc.contributor.authorLattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4771298P1 |
dc.contributor.author.fl_str_mv |
Grande, Rodrigo Stanislawczuk |
contributor_str_mv |
Loguércio, Alessandro Dourado Farago, Paulo Vitor Calixto, Abraham Lincoln Sabóia, Vicente de Paulo Aragão Assad, Roberley Araújo |
dc.subject.por.fl_str_mv |
adesivo Clorexidina resistência de união dentina |
topic |
adesivo Clorexidina resistência de união dentina adhesive Chlorhexidine bond-strength dentin CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
dc.subject.eng.fl_str_mv |
adhesive Chlorhexidine bond-strength dentin |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
description |
The aim of this work were investigate the microtensile bond strength (μTBS), nanoleakage (NL), nano-hardness (NH) and Young’s modulus (YM) of resin-dentin bonding components produced by two simplified etch-and-rinse adhesive with different concentrations of chlorhexidine diacetate (CHX). 99.9% of CHX were added to Ambar (FGM) and XP Bond (Dentsply) in concentrations of 0, 0.01, 0.05, 0.1 and 0.2 wt%. Resin-dentin bonded sticks (0.8 mm2) were prepared for μTBS testing (0.5 mm/min). For NL, some bonded sticks from each tooth were used. Nano-indentations were made on the adhesive interface and NH and YM calculated. The results of μTBS, NL and NH and YM of the hybrid layers of the CHX-free and CHX-containing adhesives were statistically similar (p > 0.05) on immediately time. After 12 months, significant reductions of μTBS were observed for both adhesives in the control group (p< 0.05). In CHX-containing adhesives or CHX-free groups the BS remained stable for both systems. NL was more evident in the control than in the experimental groups (p < 0.05) both in IM and 12 months periods. Conclusions: CHX in concentrations lower than 0.1 wt% incorporated in the two simplified etch-and-rinse adhesives did not impair the immediate resin-dentin bond strength, nanoleakage and mechanical properties of the adhesive and hybrid layers. |
publishDate |
2012 |
dc.date.issued.fl_str_mv |
2012-11-30 |
dc.date.available.fl_str_mv |
2013-08-21 2017-07-24T19:22:28Z |
dc.date.accessioned.fl_str_mv |
2017-07-24T19:22:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
GRANDE, Rodrigo Stanislawczuk. Evaluation of diacetate chlorhexidine-containing adhesives. 2012. 160 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2012. |
dc.identifier.uri.fl_str_mv |
http://tede2.uepg.br/jspui/handle/prefix/1821 |
identifier_str_mv |
GRANDE, Rodrigo Stanislawczuk. Evaluation of diacetate chlorhexidine-containing adhesives. 2012. 160 f. Tese (Doutorado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2012. |
url |
http://tede2.uepg.br/jspui/handle/prefix/1821 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UNIVERSIDADE ESTADUAL DE PONTA GROSSA |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Odontologia |
dc.publisher.initials.fl_str_mv |
UEPG |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Clinica Integrada, Dentística Restauradora e Periodontia |
publisher.none.fl_str_mv |
UNIVERSIDADE ESTADUAL DE PONTA GROSSA |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da UEPG instname:Universidade Estadual de Ponta Grossa (UEPG) instacron:UEPG |
instname_str |
Universidade Estadual de Ponta Grossa (UEPG) |
instacron_str |
UEPG |
institution |
UEPG |
reponame_str |
Biblioteca Digital de Teses e Dissertações da UEPG |
collection |
Biblioteca Digital de Teses e Dissertações da UEPG |
bitstream.url.fl_str_mv |
http://tede2.uepg.br/jspui/bitstream/prefix/1821/1/RODRIGO%20S%20GRANDE.pdf |
bitstream.checksum.fl_str_mv |
965396f452f58590edf14d60a01a07f9 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da UEPG - Universidade Estadual de Ponta Grossa (UEPG) |
repository.mail.fl_str_mv |
bicen@uepg.br||mv_fidelis@yahoo.com.br |
_version_ |
1809460456132182016 |