Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos

Detalhes bibliográficos
Autor(a) principal: Silva, Rodrigo Coutinho da
Data de Publicação: 2020
Outros Autores: coutinhods10@gmail.com
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UERJ
Texto Completo: http://www.bdtd.uerj.br/handle/1/17685
Resumo: The Dispersive Liquid-liquid Microextraction (DLLME) is a technique for extraction and concentration of target compounds applied to aqueous matrices of high complexity, such as sewage, industrial effluents and environmental samples. Bisphenol and benzophenone are widely applied in the manufacture of products in different industrial sectors and have been increasingly detected in different environmental and biological matrices. These compounds are associated to a variety of physiological dysfunctions and health impacts. Therefore, proper detection and quantification of bisphenols and benzophenone in aqueous matrices are necessary. The objective of this study was to find the best condition for a joint extraction/recovery process of Bisphenol A (BPA), Bisphenol S (BPS), Bisphenol F (BPF), Bisphenol AF (BPAF) and Benzophenone (BZP) by Dispersive Liquid-liquid Microextraction (DLLME), using the statistical approach Design of Experiments (DoE) for process optimization. In the present study, optimised DLLME was used for extraction/recovery of these compounds in complex aqueous matrices. Analytes were identified and quantified using a Xevo TQD®, Quadrupole (UPLC-MS/MS Waters) equipment. The selection of variables and conditions considered relevant for optimization of DLLME was done with the construction of two successive matrices of Plackett-Burman Design (PB) followed by a Central Composite Rotatable Design (CCRD) for a joint optimization. After the optimization, the best extraction condition was applied to five real samples (raw and treated wastewaters and surface waters) obtained in Rio de Janeiro city, Brazil. The recovery efficiencies ranged from 83 to 121% for BPA, 76 to 91% for BPS, 89 to 98% for BPF, 60% to 92% for BPAF and 81 to 99% for BZP. The concentrations of target analytes found in real samples were: BPA (0.054-150 µg L-1), BPS (0.329-18.2 µg L-1), BPF (0.048-0.091 µg L-1), BPAF (0.005-0.027 µg L-1), BZP (0.402-0.923 µg L-1). The association of DLLME with the UPLC-MS/MS met the validation requirements adopted and enabled high analytical standards. Additional advantages of applying this extraction technique instead of SPE commonly used is the low analytical cost per analysis ($0.10 USD) and low sample volume required, making it possible to process a larger number of samples quickly, with simplicity and efficiency, besides being environmentally friend.
id UERJ_9bddcca02035080c3c3e35e1968133bb
oai_identifier_str oai:www.bdtd.uerj.br:1/17685
network_acronym_str UERJ
network_name_str Biblioteca Digital de Teses e Dissertações da UERJ
repository_id_str 2903
spelling Gomes, Marcia Marqueshttp://lattes.cnpq.br/7937368027614414Vianna, Marco Tadeu Gomeshttp://lattes.cnpq.br/2498241705831482Moreira, Davyson de Limahttp://lattes.cnpq.br/7863875298510179Corrêa, Sergio Machadohttp://lattes.cnpq.br/0036129846822289http://lattes.cnpq.br/6312741653785855Silva, Rodrigo Coutinho dacoutinhods10@gmail.com2022-05-04T14:11:00Z2020-05-04SILVA, Rodrigo Coutinho da. Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos. 2020. 95 f. Dissertação (Mestrado em Engenharia Ambiental) - Faculdade de Engenharia, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2020.http://www.bdtd.uerj.br/handle/1/17685The Dispersive Liquid-liquid Microextraction (DLLME) is a technique for extraction and concentration of target compounds applied to aqueous matrices of high complexity, such as sewage, industrial effluents and environmental samples. Bisphenol and benzophenone are widely applied in the manufacture of products in different industrial sectors and have been increasingly detected in different environmental and biological matrices. These compounds are associated to a variety of physiological dysfunctions and health impacts. Therefore, proper detection and quantification of bisphenols and benzophenone in aqueous matrices are necessary. The objective of this study was to find the best condition for a joint extraction/recovery process of Bisphenol A (BPA), Bisphenol S (BPS), Bisphenol F (BPF), Bisphenol AF (BPAF) and Benzophenone (BZP) by Dispersive Liquid-liquid Microextraction (DLLME), using the statistical approach Design of Experiments (DoE) for process optimization. In the present study, optimised DLLME was used for extraction/recovery of these compounds in complex aqueous matrices. Analytes were identified and quantified using a Xevo TQD®, Quadrupole (UPLC-MS/MS Waters) equipment. The selection of variables and conditions considered relevant for optimization of DLLME was done with the construction of two successive matrices of Plackett-Burman Design (PB) followed by a Central Composite Rotatable Design (CCRD) for a joint optimization. After the optimization, the best extraction condition was applied to five real samples (raw and treated wastewaters and surface waters) obtained in Rio de Janeiro city, Brazil. The recovery efficiencies ranged from 83 to 121% for BPA, 76 to 91% for BPS, 89 to 98% for BPF, 60% to 92% for BPAF and 81 to 99% for BZP. The concentrations of target analytes found in real samples were: BPA (0.054-150 µg L-1), BPS (0.329-18.2 µg L-1), BPF (0.048-0.091 µg L-1), BPAF (0.005-0.027 µg L-1), BZP (0.402-0.923 µg L-1). The association of DLLME with the UPLC-MS/MS met the validation requirements adopted and enabled high analytical standards. Additional advantages of applying this extraction technique instead of SPE commonly used is the low analytical cost per analysis ($0.10 USD) and low sample volume required, making it possible to process a larger number of samples quickly, with simplicity and efficiency, besides being environmentally friend.O método de microextração líquido-líquido dispersiva (MELLD) é uma técnica de extração e concentração de compostos-alvo aplicada a matrizes aquosas de alta complexidade, tais como efluentes urbanos, industriais e outras amostras ambientais. Bisfenóis e Benzofenona são substâncias orgânicas amplamente aplicadas na manufatura de produtos em diferentes setores industriais que têm sido frequentemente encontradas em diferentes matrizes ambientais e biológicas. Sabe-se atualmente que tais substâncias estão associadas a uma variedade de disfunções fisiológicas e agravos à saúde. Portanto, a detecção/quantificação segura dessas substâncias faz-se necessária. O objetivo do presente trabalho foi encontrar as melhores condições para extração e recuperação simultânea de Bisfenol A (BPA), Bisfenol S (BPS), Bisfenol F (BPF), Bisfenol AF (BPAF) e Benzofenona (BZP) por meio do método de Microextração Líquido-Líquido Dispersiva (MELLD), utilizando-se para tanto, a abordagem de Desenho Experimental (DoE) para otimização de processos. Em seguida, o MELLD otimizado foi utilizado na extração/recuperação dessas substâncias em matrizes aquosas complexas. Os analitos foram identificados e quantificados utilizando-se cromatografia líquida de ultra eficiência e espectrometria de massas com Xevo TQD® Quadrupolo (UPLC-MS/MS Waters). As variáveis e as condições consideradas relevantes para otimização da MELLD foram escolhidas por meio da construção sucessiva de duas matrizes de Plackett-Burman Design (PB), seguida de Delineamento Composto Central Rotacional (CCRD) para otimização simultânea do conjunto de substâncias. Após otimização, as condições que resultaram na melhor extração foram aplicadas a cinco amostras aquosas reais (esgotos bruto e tratado e águas superficiais) obtidas na cidade do Rio de Janeiro. As eficiências de recuperação variavam de 83%-121% para BPA, 76%-91% para BPS, 89%-98% para BPF, 60%-92% para BPAF e 81.5%-99% para BZP. As concentrações das substâncias-alvo encontradas nas amostras reais foram: BPA (0,054-150 µg L-1), BPS (0,329-18,2 µg L-1), BPF (0,048-0,091 µg L-1), BPAF (0,005-0,027 µg L-1), BZP (0,402-0,923 µg L-1). A associação de MELLD com UPLC-MS/MS atendeu aos requisitos de validação adotados. Destacam-se as seguintes vantagens na aplicação de tal técnica de extração, quando comparada à técnica SPE mais comumente utilizada: baixo custo analítico (0,10 USD por amostra); baixo volume de amostra requerido; ausência de resíduos gerados por métodos que utilizam cartuchos, permitindo assim a condução de análises cromatográficas de um número maior de amostras de forma mais rápida, com eficiência e simplicidade e ambientalmente mais sustentável.Submitted by Julia CTC/B (julia.vieira@uerj.br) on 2022-05-04T14:11:00Z No. of bitstreams: 1 Dissertação - Rodrigo Coutinho da Silva - 2020 - Completo.pdf: 2949240 bytes, checksum: 0d71525f9eaf27990e0a9ea08f0f6ec5 (MD5)Made available in DSpace on 2022-05-04T14:11:00Z (GMT). No. of bitstreams: 1 Dissertação - Rodrigo Coutinho da Silva - 2020 - Completo.pdf: 2949240 bytes, checksum: 0d71525f9eaf27990e0a9ea08f0f6ec5 (MD5) Previous issue date: 2020-05-04application/pdfporUniversidade do Estado do Rio de JaneiroPrograma de Pós-Graduação em Engenharia AmbientalUERJBrasilCentro de Tecnologia e Ciências::Faculdade de EngenhariaEnvironmental engineeringWater - PollutionExtraction (Chemistry)Liquid chromatographyMass spectrometryEngenharia ambientalÁgua - PoluiçãoExtração (Química)Cromatografia a líquidoEspectrometria de massaENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAOMicroextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processosDispersive liquid-liquid microextraction do detect bisphenols (A, S, F, AF) and benzophenone in real complex aqueous samples: design of experiments and process optimizationinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UERJinstname:Universidade do Estado do Rio de Janeiro (UERJ)instacron:UERJORIGINALDissertação - Rodrigo Coutinho da Silva - 2020 - Completo.pdfDissertação - Rodrigo Coutinho da Silva - 2020 - Completo.pdfapplication/pdf2949240http://www.bdtd.uerj.br/bitstream/1/17685/2/Disserta%C3%A7%C3%A3o+-+Rodrigo+Coutinho+da+Silva+-+2020+-+Completo.pdf0d71525f9eaf27990e0a9ea08f0f6ec5MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82123http://www.bdtd.uerj.br/bitstream/1/17685/1/license.txte5502652da718045d7fcd832b79fca29MD511/176852024-02-27 14:46:45.542oai:www.bdtd.uerj.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://www.bdtd.uerj.br/PUBhttps://www.bdtd.uerj.br:8443/oai/requestbdtd.suporte@uerj.bropendoar:29032024-02-27T17:46:45Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)false
dc.title.por.fl_str_mv Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
dc.title.alternative.eng.fl_str_mv Dispersive liquid-liquid microextraction do detect bisphenols (A, S, F, AF) and benzophenone in real complex aqueous samples: design of experiments and process optimization
title Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
spellingShingle Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
Silva, Rodrigo Coutinho da
Environmental engineering
Water - Pollution
Extraction (Chemistry)
Liquid chromatography
Mass spectrometry
Engenharia ambiental
Água - Poluição
Extração (Química)
Cromatografia a líquido
Espectrometria de massa
ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO
title_short Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
title_full Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
title_fullStr Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
title_full_unstemmed Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
title_sort Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos
author Silva, Rodrigo Coutinho da
author_facet Silva, Rodrigo Coutinho da
coutinhods10@gmail.com
author_role author
author2 coutinhods10@gmail.com
author2_role author
dc.contributor.advisor1.fl_str_mv Gomes, Marcia Marques
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/7937368027614414
dc.contributor.advisor-co1.fl_str_mv Vianna, Marco Tadeu Gomes
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/2498241705831482
dc.contributor.referee1.fl_str_mv Moreira, Davyson de Lima
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/7863875298510179
dc.contributor.referee2.fl_str_mv Corrêa, Sergio Machado
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/0036129846822289
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/6312741653785855
dc.contributor.author.fl_str_mv Silva, Rodrigo Coutinho da
coutinhods10@gmail.com
contributor_str_mv Gomes, Marcia Marques
Vianna, Marco Tadeu Gomes
Moreira, Davyson de Lima
Corrêa, Sergio Machado
dc.subject.eng.fl_str_mv Environmental engineering
Water - Pollution
Extraction (Chemistry)
Liquid chromatography
Mass spectrometry
topic Environmental engineering
Water - Pollution
Extraction (Chemistry)
Liquid chromatography
Mass spectrometry
Engenharia ambiental
Água - Poluição
Extração (Química)
Cromatografia a líquido
Espectrometria de massa
ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO
dc.subject.por.fl_str_mv Engenharia ambiental
Água - Poluição
Extração (Química)
Cromatografia a líquido
Espectrometria de massa
dc.subject.cnpq.fl_str_mv ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL::CONTROLE DA POLUICAO
description The Dispersive Liquid-liquid Microextraction (DLLME) is a technique for extraction and concentration of target compounds applied to aqueous matrices of high complexity, such as sewage, industrial effluents and environmental samples. Bisphenol and benzophenone are widely applied in the manufacture of products in different industrial sectors and have been increasingly detected in different environmental and biological matrices. These compounds are associated to a variety of physiological dysfunctions and health impacts. Therefore, proper detection and quantification of bisphenols and benzophenone in aqueous matrices are necessary. The objective of this study was to find the best condition for a joint extraction/recovery process of Bisphenol A (BPA), Bisphenol S (BPS), Bisphenol F (BPF), Bisphenol AF (BPAF) and Benzophenone (BZP) by Dispersive Liquid-liquid Microextraction (DLLME), using the statistical approach Design of Experiments (DoE) for process optimization. In the present study, optimised DLLME was used for extraction/recovery of these compounds in complex aqueous matrices. Analytes were identified and quantified using a Xevo TQD®, Quadrupole (UPLC-MS/MS Waters) equipment. The selection of variables and conditions considered relevant for optimization of DLLME was done with the construction of two successive matrices of Plackett-Burman Design (PB) followed by a Central Composite Rotatable Design (CCRD) for a joint optimization. After the optimization, the best extraction condition was applied to five real samples (raw and treated wastewaters and surface waters) obtained in Rio de Janeiro city, Brazil. The recovery efficiencies ranged from 83 to 121% for BPA, 76 to 91% for BPS, 89 to 98% for BPF, 60% to 92% for BPAF and 81 to 99% for BZP. The concentrations of target analytes found in real samples were: BPA (0.054-150 µg L-1), BPS (0.329-18.2 µg L-1), BPF (0.048-0.091 µg L-1), BPAF (0.005-0.027 µg L-1), BZP (0.402-0.923 µg L-1). The association of DLLME with the UPLC-MS/MS met the validation requirements adopted and enabled high analytical standards. Additional advantages of applying this extraction technique instead of SPE commonly used is the low analytical cost per analysis ($0.10 USD) and low sample volume required, making it possible to process a larger number of samples quickly, with simplicity and efficiency, besides being environmentally friend.
publishDate 2020
dc.date.issued.fl_str_mv 2020-05-04
dc.date.accessioned.fl_str_mv 2022-05-04T14:11:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SILVA, Rodrigo Coutinho da. Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos. 2020. 95 f. Dissertação (Mestrado em Engenharia Ambiental) - Faculdade de Engenharia, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2020.
dc.identifier.uri.fl_str_mv http://www.bdtd.uerj.br/handle/1/17685
identifier_str_mv SILVA, Rodrigo Coutinho da. Microextração líquido-líquido dispersiva na determinação de bisfenóis (A, S, F, AF) e de benzofenona em amostras aquosas reais e complexas: desenho experimental e otimização de processos. 2020. 95 f. Dissertação (Mestrado em Engenharia Ambiental) - Faculdade de Engenharia, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2020.
url http://www.bdtd.uerj.br/handle/1/17685
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Engenharia Ambiental
dc.publisher.initials.fl_str_mv UERJ
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Centro de Tecnologia e Ciências::Faculdade de Engenharia
publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UERJ
instname:Universidade do Estado do Rio de Janeiro (UERJ)
instacron:UERJ
instname_str Universidade do Estado do Rio de Janeiro (UERJ)
instacron_str UERJ
institution UERJ
reponame_str Biblioteca Digital de Teses e Dissertações da UERJ
collection Biblioteca Digital de Teses e Dissertações da UERJ
bitstream.url.fl_str_mv http://www.bdtd.uerj.br/bitstream/1/17685/2/Disserta%C3%A7%C3%A3o+-+Rodrigo+Coutinho+da+Silva+-+2020+-+Completo.pdf
http://www.bdtd.uerj.br/bitstream/1/17685/1/license.txt
bitstream.checksum.fl_str_mv 0d71525f9eaf27990e0a9ea08f0f6ec5
e5502652da718045d7fcd832b79fca29
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)
repository.mail.fl_str_mv bdtd.suporte@uerj.br
_version_ 1811728710006472704