Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry

Detalhes bibliográficos
Autor(a) principal: Lepri, Fábio G.
Data de Publicação: 2010
Outros Autores: Borges, Daniel L. G., Araujo, Rennan Geovanny Oliveira, Welz, Bernhard, Wendler, Frank, Krieg, Marcus, Becker-Ross, Helmut
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFBA
Texto Completo: http://www.repositorio.ufba.br/ri/handle/ri/5785
Resumo: Acesso restrito: Texto completo. p. 980-987
id UFBA-2_608d8ca1fbd7ad32e7a8af784c8be2ee
oai_identifier_str oai:repositorio.ufba.br:ri/5785
network_acronym_str UFBA-2
network_name_str Repositório Institucional da UFBA
repository_id_str 1932
spelling Lepri, Fábio G.Borges, Daniel L. G.Araujo, Rennan Geovanny OliveiraWelz, BernhardWendler, FrankKrieg, MarcusBecker-Ross, HelmutLepri, Fábio G.Borges, Daniel L. G.Araujo, Rennan Geovanny OliveiraWelz, BernhardWendler, FrankKrieg, MarcusBecker-Ross, Helmut2012-05-08T11:57:13Z20101873-3573http://www.repositorio.ufba.br/ri/handle/ri/5785v. 81, n. 3Acesso restrito: Texto completo. p. 980-987Reactivity and concentration of additives, especially activated charcoal, employed for the Lyocell process, enhance the complexity of reactions in cellulose/N-methylmorpholine-N-oxide monohydrate solutions. Analytical control of the starting materials is a basic requirement to know the concentration of heavy metals, which are potential initiators of autocatalytic reactions. Seven activated charcoal and two carbon black samples have been analyzed regarding their content of seven elements, Cr, Cu, Fe, Mn, Mo, Ni and V using direct solid sampling high-resolution continuum source graphite furnace AAS (SS-HR-CS GF AAS) and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acidic digestion as a reference method. The limits of detection of the former technique are 1–2 orders of magnitude lower than those of ICP OES and comparable to those of more sophisticated techniques. For iron the working range of HR-CS GF AAS has been expanded by simultaneous measurement at two secondary absorption lines (344,099nm and 344,399 nm). Partial least-squares regression between measured and calculated temperatures for beginning exothermicity (Ton) has been used to investigate the prediction capability of the investigated techniques. Whereas the ICP OES measurements for seven elements resulted in an error of prediction of 3.67%, the results obtained by SS-HR-CS GF AAS exhibited a correlation coefficient of 0.99 and an error of prediction of only 0.68%. Acceptable correlation has been obtained with the latter technique measuring only three to four elements.Submitted by JURANDI DE SOUZA SILVA (jssufba@hotmail.com) on 2012-05-08T11:57:13Z No. of bitstreams: 1 __ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf: 351618 bytes, checksum: e9441ce9afd123108a2efa091179a96e (MD5)Made available in DSpace on 2012-05-08T11:57:13Z (GMT). No. of bitstreams: 1 __ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf: 351618 bytes, checksum: e9441ce9afd123108a2efa091179a96e (MD5) Previous issue date: 2010DOI: 10.1016/j.talanta.2010.01.050reponame:Repositório Institucional da UFBAinstname:Universidade Federal da Bahia (UFBA)instacron:UFBALyocell processActivated charcoalTrace element determinationDirect solid sampling analysisHigh-resolution continuum source atomic absorption spectrometryInductively coupled plasma optical emission spectrometryDetermination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometryTALANTAinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article10000-01-01enginfo:eu-repo/semantics/openAccessORIGINAL__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdfapplication/pdf351618https://repositorio.ufba.br/bitstream/ri/5785/1/__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdfe9441ce9afd123108a2efa091179a96eMD51LICENSElicense.txtlicense.txttext/plain1762https://repositorio.ufba.br/bitstream/ri/5785/2/license.txt1b89a9a0548218172d7c829f87a0eab9MD52TEXT__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf.txt__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf.txtExtracted texttext/plain42995https://repositorio.ufba.br/bitstream/ri/5785/3/__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf.txt14fe0985513f821be028774bef745c0eMD53ri/57852022-07-05 14:03:50.535oai:repositorio.ufba.br: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Repositório InstitucionalPUBhttp://192.188.11.11:8080/oai/requestopendoar:19322022-07-05T17:03:50Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)false
dc.title.pt_BR.fl_str_mv Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
dc.title.alternative.pt_BR.fl_str_mv TALANTA
title Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
spellingShingle Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
Lepri, Fábio G.
Lyocell process
Activated charcoal
Trace element determination
Direct solid sampling analysis
High-resolution continuum source atomic absorption spectrometry
Inductively coupled plasma optical emission spectrometry
title_short Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
title_full Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
title_fullStr Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
title_full_unstemmed Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
title_sort Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry
author Lepri, Fábio G.
author_facet Lepri, Fábio G.
Borges, Daniel L. G.
Araujo, Rennan Geovanny Oliveira
Welz, Bernhard
Wendler, Frank
Krieg, Marcus
Becker-Ross, Helmut
author_role author
author2 Borges, Daniel L. G.
Araujo, Rennan Geovanny Oliveira
Welz, Bernhard
Wendler, Frank
Krieg, Marcus
Becker-Ross, Helmut
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Lepri, Fábio G.
Borges, Daniel L. G.
Araujo, Rennan Geovanny Oliveira
Welz, Bernhard
Wendler, Frank
Krieg, Marcus
Becker-Ross, Helmut
Lepri, Fábio G.
Borges, Daniel L. G.
Araujo, Rennan Geovanny Oliveira
Welz, Bernhard
Wendler, Frank
Krieg, Marcus
Becker-Ross, Helmut
dc.subject.por.fl_str_mv Lyocell process
Activated charcoal
Trace element determination
Direct solid sampling analysis
High-resolution continuum source atomic absorption spectrometry
Inductively coupled plasma optical emission spectrometry
topic Lyocell process
Activated charcoal
Trace element determination
Direct solid sampling analysis
High-resolution continuum source atomic absorption spectrometry
Inductively coupled plasma optical emission spectrometry
description Acesso restrito: Texto completo. p. 980-987
publishDate 2010
dc.date.issued.fl_str_mv 2010
dc.date.accessioned.fl_str_mv 2012-05-08T11:57:13Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.repositorio.ufba.br/ri/handle/ri/5785
dc.identifier.issn.none.fl_str_mv 1873-3573
dc.identifier.number.pt_BR.fl_str_mv v. 81, n. 3
identifier_str_mv 1873-3573
v. 81, n. 3
url http://www.repositorio.ufba.br/ri/handle/ri/5785
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.pt_BR.fl_str_mv DOI: 10.1016/j.talanta.2010.01.050
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFBA
instname:Universidade Federal da Bahia (UFBA)
instacron:UFBA
instname_str Universidade Federal da Bahia (UFBA)
instacron_str UFBA
institution UFBA
reponame_str Repositório Institucional da UFBA
collection Repositório Institucional da UFBA
bitstream.url.fl_str_mv https://repositorio.ufba.br/bitstream/ri/5785/1/__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf
https://repositorio.ufba.br/bitstream/ri/5785/2/license.txt
https://repositorio.ufba.br/bitstream/ri/5785/3/__ac.els-cdn.com_S003991...d3a81fb91de6c7d3495e5a884ac10.pdf.txt
bitstream.checksum.fl_str_mv e9441ce9afd123108a2efa091179a96e
1b89a9a0548218172d7c829f87a0eab9
14fe0985513f821be028774bef745c0e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)
repository.mail.fl_str_mv
_version_ 1808459397608767488