Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

Detalhes bibliográficos
Autor(a) principal: Araujo, Rennan Geovanny Oliveira
Data de Publicação: 2013
Outros Autores: Vignola, Fabíola, Castilho, Ivan N. B., Welz, Bernhard, Vale, Maria Goreti R., Smichowski, Patricia, Ferreira, Sergio Luis Costa, Becker-Ross, Helmut
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFBA
Texto Completo: http://repositorio.ufba.br/ri/handle/ri/15030
Resumo: Texto completo: acesso restrito. p. 36–40
id UFBA-2_d79e274b7891a939a1fa3f55965abdb5
oai_identifier_str oai:repositorio.ufba.br:ri/15030
network_acronym_str UFBA-2
network_name_str Repositório Institucional da UFBA
repository_id_str 1932
spelling Araujo, Rennan Geovanny OliveiraVignola, FabíolaCastilho, Ivan N. B.Welz, BernhardVale, Maria Goreti R.Smichowski, PatriciaFerreira, Sergio Luis CostaBecker-Ross, HelmutAraujo, Rennan Geovanny OliveiraVignola, FabíolaCastilho, Ivan N. B.Welz, BernhardVale, Maria Goreti R.Smichowski, PatriciaFerreira, Sergio Luis CostaBecker-Ross, Helmut2014-05-29T13:54:18Z20130026-265Xhttp://repositorio.ufba.br/ri/handle/ri/15030v. 109Texto completo: acesso restrito. p. 36–40The present work aims at the determination of silver in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry. The secondary line at 338.289 nm was used for all measurements. A manual solid sampling accessory and solid sampling platforms were used for sample introduction. A mass of 400 μg of ruthenium was thermally deposited on the platform surface as permanent modifier. The optimum pyrolysis and atomization temperature was 1,000 and 2,000 °C, respectively. Aqueous standard solutions were used for calibration exclusively. The analytical parameters obtained for the proposed method were as follows: characteristic mass, 4.4 pg Ag; detection limit (3σ, n = 10), 17 ng g− 1; and quantification limit (10σ, n = 10), 58 ng g− 1. These limits are equivalent to 0.05 and 0.16 ng m− 3, respectively, for 0.36 mg of sample mass (filter + APM) and an average volume of 1,440 m3 air that had passed through the filter. The certified reference material urban particulate matter, NIST 1648, was used for checking the accuracy. Four filter samples with APM collected in Buenos Aires, Argentina, were analyzed. According to our study, the concentration of silver (average ± confidence interval at 95% level, n = 5) varied between 0.64 ± 0.06 and 1.18 ± 0.07 μg g− 1, corresponding to 1.99 ± 0.11 and 4.54 ± 0.26 ng m− 3. The precision, expressed as relative standard deviation, varied between 1.6 and 7.1% (n = 5). The analytical method proved to be simple, fast and reliable.Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2014-05-29T13:54:18Z No. of bitstreams: 1 1-s2.0-S0026265X12001270-main.pdf: 374813 bytes, checksum: 9e24884b818f84498479904799d6df24 (MD5)Made available in DSpace on 2014-05-29T13:54:18Z (GMT). No. of bitstreams: 1 1-s2.0-S0026265X12001270-main.pdf: 374813 bytes, checksum: 9e24884b818f84498479904799d6df24 (MD5) Previous issue date: 2013http://dx.doi.org/10.1016/j.microc.2012.05.009reponame:Repositório Institucional da UFBAinstname:Universidade Federal da Bahia (UFBA)instacron:UFBASilver determinationGlass fiber filtersAirborne particulate matterDirect solid sampling analysisHR-CS GF AASDetermination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid samplingMicrochemical Journalinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article10000-01-01info:eu-repo/semantics/openAccessengLICENSElicense.txtlicense.txttext/plain1345https://repositorio.ufba.br/bitstream/ri/15030/2/license.txt0d4b811ef71182510d2015daa7c8a900MD52ORIGINAL1-s2.0-S0026265X12001270-main.pdf1-s2.0-S0026265X12001270-main.pdfapplication/pdf374813https://repositorio.ufba.br/bitstream/ri/15030/1/1-s2.0-S0026265X12001270-main.pdf9e24884b818f84498479904799d6df24MD51TEXT1-s2.0-S0026265X12001270-main.pdf.txt1-s2.0-S0026265X12001270-main.pdf.txtExtracted texttext/plain28293https://repositorio.ufba.br/bitstream/ri/15030/3/1-s2.0-S0026265X12001270-main.pdf.txte61b49a0965f8331ba7ed6c9af6d30c3MD53ri/150302022-08-08 13:17:31.968oai:repositorio.ufba.br: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Repositório InstitucionalPUBhttp://192.188.11.11:8080/oai/requestopendoar:19322022-08-08T16:17:31Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)false
dc.title.pt_BR.fl_str_mv Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
dc.title.alternative.pt_BR.fl_str_mv Microchemical Journal
title Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
spellingShingle Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
Araujo, Rennan Geovanny Oliveira
Silver determination
Glass fiber filters
Airborne particulate matter
Direct solid sampling analysis
HR-CS GF AAS
title_short Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
title_full Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
title_fullStr Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
title_full_unstemmed Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
title_sort Determination of silver in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling
author Araujo, Rennan Geovanny Oliveira
author_facet Araujo, Rennan Geovanny Oliveira
Vignola, Fabíola
Castilho, Ivan N. B.
Welz, Bernhard
Vale, Maria Goreti R.
Smichowski, Patricia
Ferreira, Sergio Luis Costa
Becker-Ross, Helmut
author_role author
author2 Vignola, Fabíola
Castilho, Ivan N. B.
Welz, Bernhard
Vale, Maria Goreti R.
Smichowski, Patricia
Ferreira, Sergio Luis Costa
Becker-Ross, Helmut
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Araujo, Rennan Geovanny Oliveira
Vignola, Fabíola
Castilho, Ivan N. B.
Welz, Bernhard
Vale, Maria Goreti R.
Smichowski, Patricia
Ferreira, Sergio Luis Costa
Becker-Ross, Helmut
Araujo, Rennan Geovanny Oliveira
Vignola, Fabíola
Castilho, Ivan N. B.
Welz, Bernhard
Vale, Maria Goreti R.
Smichowski, Patricia
Ferreira, Sergio Luis Costa
Becker-Ross, Helmut
dc.subject.por.fl_str_mv Silver determination
Glass fiber filters
Airborne particulate matter
Direct solid sampling analysis
HR-CS GF AAS
topic Silver determination
Glass fiber filters
Airborne particulate matter
Direct solid sampling analysis
HR-CS GF AAS
description Texto completo: acesso restrito. p. 36–40
publishDate 2013
dc.date.issued.fl_str_mv 2013
dc.date.accessioned.fl_str_mv 2014-05-29T13:54:18Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufba.br/ri/handle/ri/15030
dc.identifier.issn.none.fl_str_mv 0026-265X
dc.identifier.number.pt_BR.fl_str_mv v. 109
identifier_str_mv 0026-265X
v. 109
url http://repositorio.ufba.br/ri/handle/ri/15030
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.pt_BR.fl_str_mv http://dx.doi.org/10.1016/j.microc.2012.05.009
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFBA
instname:Universidade Federal da Bahia (UFBA)
instacron:UFBA
instname_str Universidade Federal da Bahia (UFBA)
instacron_str UFBA
institution UFBA
reponame_str Repositório Institucional da UFBA
collection Repositório Institucional da UFBA
bitstream.url.fl_str_mv https://repositorio.ufba.br/bitstream/ri/15030/2/license.txt
https://repositorio.ufba.br/bitstream/ri/15030/1/1-s2.0-S0026265X12001270-main.pdf
https://repositorio.ufba.br/bitstream/ri/15030/3/1-s2.0-S0026265X12001270-main.pdf.txt
bitstream.checksum.fl_str_mv 0d4b811ef71182510d2015daa7c8a900
9e24884b818f84498479904799d6df24
e61b49a0965f8331ba7ed6c9af6d30c3
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)
repository.mail.fl_str_mv
_version_ 1808459478921641984