Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | por |
Título da fonte: | Repositório Institucional da Universidade Federal do Ceará (UFC) |
Texto Completo: | http://www.repositorio.ufc.br/handle/riufc/64693 |
Resumo: | This work presents preliminary results of a digital frequency meter that has been designed to measure the frequency of oscillatory vibrations in respiratory physiotherapy devices. Maintain a frequency around 13Hz is important to keep an efficient treatment. Therefore, the proposed circuits and systems are intended to give a visual feedback to the patient with a suggestion of the optimal blow strength. A Linear Hall-Efect Sensor was coupled to the physiotherapy device and the output signal is conditioned through a set of lters. The Fast Fourier Transform of the conditioned signal is used in order to extract frequency domain information to be displayed in real-time to patients. |
id |
UFC-7_5c2f8ad88fb908ea72fa643e4588f5d2 |
---|---|
oai_identifier_str |
oai:repositorio.ufc.br:riufc/64693 |
network_acronym_str |
UFC-7 |
network_name_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository_id_str |
|
spelling |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipmentDevelopment of a digital frequency meter for signal analysis on a respiratory physiotherapy equipmentFiltroOOAFTRFSensor de efeito hall linearTécnicas de fisioterapia respiratóriaThis work presents preliminary results of a digital frequency meter that has been designed to measure the frequency of oscillatory vibrations in respiratory physiotherapy devices. Maintain a frequency around 13Hz is important to keep an efficient treatment. Therefore, the proposed circuits and systems are intended to give a visual feedback to the patient with a suggestion of the optimal blow strength. A Linear Hall-Efect Sensor was coupled to the physiotherapy device and the output signal is conditioned through a set of lters. The Fast Fourier Transform of the conditioned signal is used in order to extract frequency domain information to be displayed in real-time to patients.Este artigo apresenta os resultados preliminares do projeto de um frequencímetro digital que foi modelado para detectar as vibrações oscilatórias de um equipamente de fisioterapia respiratória. Portanto, os circuitos e sistemas propostos possuem o intuito de fornecer feedback visual para o paciente, assim como aconselhamento em relação à força desejada do sopro. Um Sensor de Efeito Hall Linear foi acoplado a um equipamento fisioterapêutico, e o sinal de saída é condicionado através de um conjunto de filtros. A Transformada Rápida de Fourier desse sinal é, então, usada para extrair informações no domínio da frequência para serem apresentadas, em tempo real, para os pacientes.Sociedade Brasileira de Automática – SBA - https://www.sba.org.br/2022-03-30T13:01:47Z2022-03-30T13:01:47Z2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectapplication/pdfSILVA, Guilherme Carvalho da; CASTRO, Raissa Moraes de; FORTE, Marcus Davi do Nascimento; NOGUEIRA, Fabrício Gonzalez; TORRICO, Bismark Claure; LOBO, Thiago Diniz; DINIZ, Denise Maria Sá Machado; SANTOS, Nathiara Ellen dos; AGUIAR, Mylena Ximenes. Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment. In: CONGRESSO BRASILEIRO DE AUTOMÁTICA, XXII., 9 a 12 set., 2018, João Pessoa - PB - Brasil. Anais[…], Campinas, Galoá, v.1, n. 1 (2019): CBA2018.2525-8311http://www.repositorio.ufc.br/handle/riufc/64693Silva, Guilherme Carvalho daCastro, Raissa Moraes deForte, Marcus Davi do NascimentoNogueira, Fabrício GonzalezTorrico, Bismark ClaureLobo, Thiago DinizDiniz, Denise Maria Sá MachadoSantos, Nathiara Ellen dosAguiar, Mylena Ximenesporreponame:Repositório Institucional da Universidade Federal do Ceará (UFC)instname:Universidade Federal do Ceará (UFC)instacron:UFCinfo:eu-repo/semantics/openAccess2022-04-01T13:52:54Zoai:repositorio.ufc.br:riufc/64693Repositório InstitucionalPUBhttp://www.repositorio.ufc.br/ri-oai/requestbu@ufc.br || repositorio@ufc.bropendoar:2024-09-11T18:33:52.227144Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC)false |
dc.title.none.fl_str_mv |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
title |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
spellingShingle |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment Silva, Guilherme Carvalho da Filtro OOAF TRF Sensor de efeito hall linear Técnicas de fisioterapia respiratória |
title_short |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
title_full |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
title_fullStr |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
title_full_unstemmed |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
title_sort |
Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment |
author |
Silva, Guilherme Carvalho da |
author_facet |
Silva, Guilherme Carvalho da Castro, Raissa Moraes de Forte, Marcus Davi do Nascimento Nogueira, Fabrício Gonzalez Torrico, Bismark Claure Lobo, Thiago Diniz Diniz, Denise Maria Sá Machado Santos, Nathiara Ellen dos Aguiar, Mylena Ximenes |
author_role |
author |
author2 |
Castro, Raissa Moraes de Forte, Marcus Davi do Nascimento Nogueira, Fabrício Gonzalez Torrico, Bismark Claure Lobo, Thiago Diniz Diniz, Denise Maria Sá Machado Santos, Nathiara Ellen dos Aguiar, Mylena Ximenes |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Silva, Guilherme Carvalho da Castro, Raissa Moraes de Forte, Marcus Davi do Nascimento Nogueira, Fabrício Gonzalez Torrico, Bismark Claure Lobo, Thiago Diniz Diniz, Denise Maria Sá Machado Santos, Nathiara Ellen dos Aguiar, Mylena Ximenes |
dc.subject.por.fl_str_mv |
Filtro OOAF TRF Sensor de efeito hall linear Técnicas de fisioterapia respiratória |
topic |
Filtro OOAF TRF Sensor de efeito hall linear Técnicas de fisioterapia respiratória |
description |
This work presents preliminary results of a digital frequency meter that has been designed to measure the frequency of oscillatory vibrations in respiratory physiotherapy devices. Maintain a frequency around 13Hz is important to keep an efficient treatment. Therefore, the proposed circuits and systems are intended to give a visual feedback to the patient with a suggestion of the optimal blow strength. A Linear Hall-Efect Sensor was coupled to the physiotherapy device and the output signal is conditioned through a set of lters. The Fast Fourier Transform of the conditioned signal is used in order to extract frequency domain information to be displayed in real-time to patients. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018 2022-03-30T13:01:47Z 2022-03-30T13:01:47Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
SILVA, Guilherme Carvalho da; CASTRO, Raissa Moraes de; FORTE, Marcus Davi do Nascimento; NOGUEIRA, Fabrício Gonzalez; TORRICO, Bismark Claure; LOBO, Thiago Diniz; DINIZ, Denise Maria Sá Machado; SANTOS, Nathiara Ellen dos; AGUIAR, Mylena Ximenes. Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment. In: CONGRESSO BRASILEIRO DE AUTOMÁTICA, XXII., 9 a 12 set., 2018, João Pessoa - PB - Brasil. Anais[…], Campinas, Galoá, v.1, n. 1 (2019): CBA2018. 2525-8311 http://www.repositorio.ufc.br/handle/riufc/64693 |
identifier_str_mv |
SILVA, Guilherme Carvalho da; CASTRO, Raissa Moraes de; FORTE, Marcus Davi do Nascimento; NOGUEIRA, Fabrício Gonzalez; TORRICO, Bismark Claure; LOBO, Thiago Diniz; DINIZ, Denise Maria Sá Machado; SANTOS, Nathiara Ellen dos; AGUIAR, Mylena Ximenes. Development of a digital frequency meter for signal analysis on a respiratory physiotherapy equipment. In: CONGRESSO BRASILEIRO DE AUTOMÁTICA, XXII., 9 a 12 set., 2018, João Pessoa - PB - Brasil. Anais[…], Campinas, Galoá, v.1, n. 1 (2019): CBA2018. 2525-8311 |
url |
http://www.repositorio.ufc.br/handle/riufc/64693 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Automática – SBA - https://www.sba.org.br/ |
publisher.none.fl_str_mv |
Sociedade Brasileira de Automática – SBA - https://www.sba.org.br/ |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Ceará (UFC) instname:Universidade Federal do Ceará (UFC) instacron:UFC |
instname_str |
Universidade Federal do Ceará (UFC) |
instacron_str |
UFC |
institution |
UFC |
reponame_str |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
collection |
Repositório Institucional da Universidade Federal do Ceará (UFC) |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Ceará (UFC) - Universidade Federal do Ceará (UFC) |
repository.mail.fl_str_mv |
bu@ufc.br || repositorio@ufc.br |
_version_ |
1813028856796282880 |