Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) |
Texto Completo: | http://repositorio.ufes.br/handle/10/1680 |
Resumo: | In a context of necessity to increase electric energy offer and to search clean and renewable energy sources, wind energy have experienced an expressive expansion through the last few years. One of the most employed wind generators, the DFIG, has its performance significantly affected by grid disturbances, especially voltage sag. Topology and control solutions have been presented to increase generator’s supportability to these phenomena. This work verifies the use of superconducting resistive current limiter placed on back-to-back converter DC-link to protect the converter and to increase low voltage ride-through for a DFIG-based wind generator. The application of superconducting technology on wind systems protection is novel and the obtained results contribute with other works in this area. Under DFIG normal operation, the superconductor doesn’t transits to conductor state and remains invisible to the system. During a voltage dip the rotor circuit current surpasses the device critical current turning the superconductor to a conductor state inserting a resistive element, limiting the hazardous current. The studies are made through electromagnetic transient simulation software PSCAD/EMTDC with implementation of a superconducting current limiter on a 2MW wind turbine. Aspects as current limitation, response influence and supportability standard attendance are evaluated for limiter inside back-to-back converter DC-link in two different settings. The obtained results demonstrate that if voltage sag occurs the limiter insertion on DC-link limits the rotor current at the same time that it maintains DC-link voltage in safe values, proving the proposal validly. |
id |
UFES_3899b5db543e56b06d40b22878831c1d |
---|---|
oai_identifier_str |
oai:repositorio.ufes.br:10/1680 |
network_acronym_str |
UFES |
network_name_str |
Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) |
repository_id_str |
2108 |
spelling |
Simonetti, Domingos Sávio LyrioAmorim, Arthur Eduardo AlvesFardin, Jussara FariasSilva, Flávio Barcelos Braz da2016-01-07T11:06:01Z2016-06-24T06:00:08Z2015-10-092015-10-09In a context of necessity to increase electric energy offer and to search clean and renewable energy sources, wind energy have experienced an expressive expansion through the last few years. One of the most employed wind generators, the DFIG, has its performance significantly affected by grid disturbances, especially voltage sag. Topology and control solutions have been presented to increase generator’s supportability to these phenomena. This work verifies the use of superconducting resistive current limiter placed on back-to-back converter DC-link to protect the converter and to increase low voltage ride-through for a DFIG-based wind generator. The application of superconducting technology on wind systems protection is novel and the obtained results contribute with other works in this area. Under DFIG normal operation, the superconductor doesn’t transits to conductor state and remains invisible to the system. During a voltage dip the rotor circuit current surpasses the device critical current turning the superconductor to a conductor state inserting a resistive element, limiting the hazardous current. The studies are made through electromagnetic transient simulation software PSCAD/EMTDC with implementation of a superconducting current limiter on a 2MW wind turbine. Aspects as current limitation, response influence and supportability standard attendance are evaluated for limiter inside back-to-back converter DC-link in two different settings. The obtained results demonstrate that if voltage sag occurs the limiter insertion on DC-link limits the rotor current at the same time that it maintains DC-link voltage in safe values, proving the proposal validly.Em um contexto de necessidade de aumento da oferta de energia elétrica e de busca por fontes renováveis e limpas de energia, a energia eólica tem experimentado um crescimento expressivo nos últimos anos. Uma das tecnologias mais empregadas em geradores eólicos, o DFIG, possui como maior susceptibilidade os distúrbios da rede, principalmente o afundamento de tensão. Soluções na topologia e no controle do gerador têm sido propostas para aumento da suportabilidade do gerador a esses fenômenos. Este trabalho avalia a utilização de um limitador de corrente supercondutor resistivo no elo-CC do conversor back-to-back para proteção do conversor e aumento da suportabilidade a afundamentos de tensão em um gerador eólico baseado em DFIG. A aplicação da tecnologia de supercondutores na proteção de sistemas eólicos é recente e os resultados obtidos nesse trabalho contribuem com os estudos feitos na área. Com o gerador DFIG operando em condições normais, o supercondutor não transita para o estado condutor, e permanece invisível à operação. Na ocorrência de um afundamento de tensão na rede a corrente no circuito de rotor aumenta ultrapassando o valor da corrente crítica e levando o supercondutor ao estado condutor, inserindo um elemento resistivo, limitando assim, a corrente. As análises são feitas utilizando o software de simulação de transitórios eletromagnéticos PSCAD/EMTDC com a implementação do limitador supercondutor em uma turbina eólica de 2MW. São avaliados aspectos tais como limitação de corrente, influência na resposta e atendimento à normativa de suportabilidade para duas posições do limitador dentro do elo-CC do conversor back-to-back. Os resultados obtidos demonstram que a inserção do limitador no elo-CC limita a corrente no rotor durante a ocorrência de afundamentos de tensão, ao mesmo tempo em que mantém a tensão do elo-CC em valores seguros, confirmando a validade da proposta.Texthttp://repositorio.ufes.br/handle/10/1680porUniversidade Federal do Espírito SantoMestrado em Engenharia ElétricaPrograma de Pós-Graduação em Engenharia ElétricaUFESBRCentro TecnológicoDispositivo limitador de correnteGeradores de indução duplamente alimentados (DFIG)Energia eólicaSupercondutividadeTurbina eólicaEngenharia Elétrica621.3Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensãoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)instname:Universidade Federal do Espírito Santo (UFES)instacron:UFESORIGINALAvaliacao do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensao.pdfAvaliacao do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensao.pdfTexto completoapplication/pdf2595378http://repositorio.ufes.br/bitstreams/6b1fcdf2-eacb-435d-b038-c34a21a97cb1/download555c76d8ac8053bf86c8ee4bdb825fe0MD51CC-LICENSElicense_urllicense_urltext/plain; charset=utf-849http://repositorio.ufes.br/bitstreams/117daeb0-d091-42fc-a60c-a60ae64cefa4/download4afdbb8c545fd630ea7db775da747b2fMD52license_textlicense_texttext/html; charset=utf-821468http://repositorio.ufes.br/bitstreams/3ec8410e-ba6e-4181-9751-f88d8717c74d/downloadae2fe251842ade1134c5d9bb99b6eefeMD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-823148http://repositorio.ufes.br/bitstreams/0cc5c6b3-9074-471a-bdb2-0eab82f9e2d2/download9da0b6dfac957114c6a7714714b86306MD54LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.ufes.br/bitstreams/7ecb9c66-3abe-4ffd-bcf4-9ce7d9af6591/download8a4605be74aa9ea9d79846c1fba20a33MD5510/16802024-07-17 17:01:13.839oai:repositorio.ufes.br:10/1680http://repositorio.ufes.brRepositório InstitucionalPUBhttp://repositorio.ufes.br/oai/requestopendoar:21082024-10-15T17:59:05.136507Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)falseTk9URTogUExBQ0UgWU9VUiBPV04gTElDRU5TRSBIRVJFClRoaXMgc2FtcGxlIGxpY2Vuc2UgaXMgcHJvdmlkZWQgZm9yIGluZm9ybWF0aW9uYWwgcHVycG9zZXMgb25seS4KCk5PTi1FWENMVVNJVkUgRElTVFJJQlVUSU9OIExJQ0VOU0UKCkJ5IHNpZ25pbmcgYW5kIHN1Ym1pdHRpbmcgdGhpcyBsaWNlbnNlLCB5b3UgKHRoZSBhdXRob3Iocykgb3IgY29weXJpZ2h0Cm93bmVyKSBncmFudHMgdG8gRFNwYWNlIFVuaXZlcnNpdHkgKERTVSkgdGhlIG5vbi1leGNsdXNpdmUgcmlnaHQgdG8gcmVwcm9kdWNlLAp0cmFuc2xhdGUgKGFzIGRlZmluZWQgYmVsb3cpLCBhbmQvb3IgZGlzdHJpYnV0ZSB5b3VyIHN1Ym1pc3Npb24gKGluY2x1ZGluZwp0aGUgYWJzdHJhY3QpIHdvcmxkd2lkZSBpbiBwcmludCBhbmQgZWxlY3Ryb25pYyBmb3JtYXQgYW5kIGluIGFueSBtZWRpdW0sCmluY2x1ZGluZyBidXQgbm90IGxpbWl0ZWQgdG8gYXVkaW8gb3IgdmlkZW8uCgpZb3UgYWdyZWUgdGhhdCBEU1UgbWF5LCB3aXRob3V0IGNoYW5naW5nIHRoZSBjb250ZW50LCB0cmFuc2xhdGUgdGhlCnN1Ym1pc3Npb24gdG8gYW55IG1lZGl1bSBvciBmb3JtYXQgZm9yIHRoZSBwdXJwb3NlIG9mIHByZXNlcnZhdGlvbi4KCllvdSBhbHNvIGFncmVlIHRoYXQgRFNVIG1heSBrZWVwIG1vcmUgdGhhbiBvbmUgY29weSBvZiB0aGlzIHN1Ym1pc3Npb24gZm9yCnB1cnBvc2VzIG9mIHNlY3VyaXR5LCBiYWNrLXVwIGFuZCBwcmVzZXJ2YXRpb24uCgpZb3UgcmVwcmVzZW50IHRoYXQgdGhlIHN1Ym1pc3Npb24gaXMgeW91ciBvcmlnaW5hbCB3b3JrLCBhbmQgdGhhdCB5b3UgaGF2ZQp0aGUgcmlnaHQgdG8gZ3JhbnQgdGhlIHJpZ2h0cyBjb250YWluZWQgaW4gdGhpcyBsaWNlbnNlLiBZb3UgYWxzbyByZXByZXNlbnQKdGhhdCB5b3VyIHN1Ym1pc3Npb24gZG9lcyBub3QsIHRvIHRoZSBiZXN0IG9mIHlvdXIga25vd2xlZGdlLCBpbmZyaW5nZSB1cG9uCmFueW9uZSdzIGNvcHlyaWdodC4KCklmIHRoZSBzdWJtaXNzaW9uIGNvbnRhaW5zIG1hdGVyaWFsIGZvciB3aGljaCB5b3UgZG8gbm90IGhvbGQgY29weXJpZ2h0LAp5b3UgcmVwcmVzZW50IHRoYXQgeW91IGhhdmUgb2J0YWluZWQgdGhlIHVucmVzdHJpY3RlZCBwZXJtaXNzaW9uIG9mIHRoZQpjb3B5cmlnaHQgb3duZXIgdG8gZ3JhbnQgRFNVIHRoZSByaWdodHMgcmVxdWlyZWQgYnkgdGhpcyBsaWNlbnNlLCBhbmQgdGhhdApzdWNoIHRoaXJkLXBhcnR5IG93bmVkIG1hdGVyaWFsIGlzIGNsZWFybHkgaWRlbnRpZmllZCBhbmQgYWNrbm93bGVkZ2VkCndpdGhpbiB0aGUgdGV4dCBvciBjb250ZW50IG9mIHRoZSBzdWJtaXNzaW9uLgoKSUYgVEhFIFNVQk1JU1NJT04gSVMgQkFTRUQgVVBPTiBXT1JLIFRIQVQgSEFTIEJFRU4gU1BPTlNPUkVEIE9SIFNVUFBPUlRFRApCWSBBTiBBR0VOQ1kgT1IgT1JHQU5JWkFUSU9OIE9USEVSIFRIQU4gRFNVLCBZT1UgUkVQUkVTRU5UIFRIQVQgWU9VIEhBVkUKRlVMRklMTEVEIEFOWSBSSUdIVCBPRiBSRVZJRVcgT1IgT1RIRVIgT0JMSUdBVElPTlMgUkVRVUlSRUQgQlkgU1VDSApDT05UUkFDVCBPUiBBR1JFRU1FTlQuCgpEU1Ugd2lsbCBjbGVhcmx5IGlkZW50aWZ5IHlvdXIgbmFtZShzKSBhcyB0aGUgYXV0aG9yKHMpIG9yIG93bmVyKHMpIG9mIHRoZQpzdWJtaXNzaW9uLCBhbmQgd2lsbCBub3QgbWFrZSBhbnkgYWx0ZXJhdGlvbiwgb3RoZXIgdGhhbiBhcyBhbGxvd2VkIGJ5IHRoaXMKbGljZW5zZSwgdG8geW91ciBzdWJtaXNzaW9uLgo= |
dc.title.none.fl_str_mv |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
title |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
spellingShingle |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão Amorim, Arthur Eduardo Alves Dispositivo limitador de corrente Geradores de indução duplamente alimentados (DFIG) Engenharia Elétrica Energia eólica Supercondutividade Turbina eólica 621.3 |
title_short |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
title_full |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
title_fullStr |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
title_full_unstemmed |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
title_sort |
Avaliação do limitador supercondutor resistivo no elo-CC do DFIG para suportabilidade a afundamentos de tensão |
author |
Amorim, Arthur Eduardo Alves |
author_facet |
Amorim, Arthur Eduardo Alves |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Simonetti, Domingos Sávio Lyrio |
dc.contributor.author.fl_str_mv |
Amorim, Arthur Eduardo Alves |
dc.contributor.referee1.fl_str_mv |
Fardin, Jussara Farias |
dc.contributor.referee2.fl_str_mv |
Silva, Flávio Barcelos Braz da |
contributor_str_mv |
Simonetti, Domingos Sávio Lyrio Fardin, Jussara Farias Silva, Flávio Barcelos Braz da |
dc.subject.por.fl_str_mv |
Dispositivo limitador de corrente Geradores de indução duplamente alimentados (DFIG) |
topic |
Dispositivo limitador de corrente Geradores de indução duplamente alimentados (DFIG) Engenharia Elétrica Energia eólica Supercondutividade Turbina eólica 621.3 |
dc.subject.cnpq.fl_str_mv |
Engenharia Elétrica |
dc.subject.br-rjbn.none.fl_str_mv |
Energia eólica Supercondutividade Turbina eólica |
dc.subject.udc.none.fl_str_mv |
621.3 |
description |
In a context of necessity to increase electric energy offer and to search clean and renewable energy sources, wind energy have experienced an expressive expansion through the last few years. One of the most employed wind generators, the DFIG, has its performance significantly affected by grid disturbances, especially voltage sag. Topology and control solutions have been presented to increase generator’s supportability to these phenomena. This work verifies the use of superconducting resistive current limiter placed on back-to-back converter DC-link to protect the converter and to increase low voltage ride-through for a DFIG-based wind generator. The application of superconducting technology on wind systems protection is novel and the obtained results contribute with other works in this area. Under DFIG normal operation, the superconductor doesn’t transits to conductor state and remains invisible to the system. During a voltage dip the rotor circuit current surpasses the device critical current turning the superconductor to a conductor state inserting a resistive element, limiting the hazardous current. The studies are made through electromagnetic transient simulation software PSCAD/EMTDC with implementation of a superconducting current limiter on a 2MW wind turbine. Aspects as current limitation, response influence and supportability standard attendance are evaluated for limiter inside back-to-back converter DC-link in two different settings. The obtained results demonstrate that if voltage sag occurs the limiter insertion on DC-link limits the rotor current at the same time that it maintains DC-link voltage in safe values, proving the proposal validly. |
publishDate |
2015 |
dc.date.submitted.none.fl_str_mv |
2015-10-09 |
dc.date.issued.fl_str_mv |
2015-10-09 |
dc.date.accessioned.fl_str_mv |
2016-01-07T11:06:01Z |
dc.date.available.fl_str_mv |
2016-06-24T06:00:08Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://repositorio.ufes.br/handle/10/1680 |
url |
http://repositorio.ufes.br/handle/10/1680 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
Text |
dc.publisher.none.fl_str_mv |
Universidade Federal do Espírito Santo Mestrado em Engenharia Elétrica |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Engenharia Elétrica |
dc.publisher.initials.fl_str_mv |
UFES |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Centro Tecnológico |
publisher.none.fl_str_mv |
Universidade Federal do Espírito Santo Mestrado em Engenharia Elétrica |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) instname:Universidade Federal do Espírito Santo (UFES) instacron:UFES |
instname_str |
Universidade Federal do Espírito Santo (UFES) |
instacron_str |
UFES |
institution |
UFES |
reponame_str |
Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) |
collection |
Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) |
bitstream.url.fl_str_mv |
http://repositorio.ufes.br/bitstreams/6b1fcdf2-eacb-435d-b038-c34a21a97cb1/download http://repositorio.ufes.br/bitstreams/117daeb0-d091-42fc-a60c-a60ae64cefa4/download http://repositorio.ufes.br/bitstreams/3ec8410e-ba6e-4181-9751-f88d8717c74d/download http://repositorio.ufes.br/bitstreams/0cc5c6b3-9074-471a-bdb2-0eab82f9e2d2/download http://repositorio.ufes.br/bitstreams/7ecb9c66-3abe-4ffd-bcf4-9ce7d9af6591/download |
bitstream.checksum.fl_str_mv |
555c76d8ac8053bf86c8ee4bdb825fe0 4afdbb8c545fd630ea7db775da747b2f ae2fe251842ade1134c5d9bb99b6eefe 9da0b6dfac957114c6a7714714b86306 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES) |
repository.mail.fl_str_mv |
|
_version_ |
1813022553934921728 |