Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico

Detalhes bibliográficos
Autor(a) principal: Loterio, Flávia Aparecida
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
Texto Completo: http://repositorio.ufes.br/handle/10/1471
Resumo: Stroke is a leading cause of damages in the neuromuscular system. Robotic devices have been widely developed and studied in order to be used in gait assistance and gait training during the rehabilitation. The goal of this work is to evaluate the assisted gait by the AROW (Assistive Robotic Walker) in post stroke hemiparetic individuals through accelerometer signals and surface Electromyography (sEMG) analysis. The analyzed muscles are vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius medialis (GM). Furthermore, the evaluation methods GAS (Goal Attainment Scaling) and SUS (System Usability Scale) were used. Nine hemiparetic subjects participate of the experiments. The gait speed was decreased using the walker and, consequently, there were some changes in the duration of gait phases, for instance longer of support phase (p = 0.0174). The muscle activation pattern for the analyzed group did not show statistically significant difference (onset VM: p= 0.4999; offset VM: p= 0.5647; onset BF: p= 0.1186; offset BF: p= 0.7823; onset TA: p= 0.5833; offset TA: p= 0.8393; onset GM: p= 0.6077; offset GM: p= 0.1429).. However, assessing the muscle activation pattern individually, some benefic changes can be noted, for example, the reduced co-activation between tibialis anterior and gastrocnemius medial. The results of evaluations through GAS (54.8) and SUS (81.4) about the use of the AROW showed good acceptance among users, and the desired results during the use of the walker were achieved. The fast adaptation, easiness of use and feeling of safety when using the device are positive points that were obtained using the AROW.
id UFES_6dd886ebd1e7231b8796b0af522b52bc
oai_identifier_str oai:repositorio.ufes.br:10/1471
network_acronym_str UFES
network_name_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
repository_id_str 2108
spelling Frizera Neto, AnselmoBastos Filho, Teodiano FreireLoterio, Flávia AparecidaAndrade, Adriano de OliveiraNogueira, Breno Valentim2015-08-14T21:06:31Z2016-06-24T06:00:06Z2015-02-202015-02-20Stroke is a leading cause of damages in the neuromuscular system. Robotic devices have been widely developed and studied in order to be used in gait assistance and gait training during the rehabilitation. The goal of this work is to evaluate the assisted gait by the AROW (Assistive Robotic Walker) in post stroke hemiparetic individuals through accelerometer signals and surface Electromyography (sEMG) analysis. The analyzed muscles are vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius medialis (GM). Furthermore, the evaluation methods GAS (Goal Attainment Scaling) and SUS (System Usability Scale) were used. Nine hemiparetic subjects participate of the experiments. The gait speed was decreased using the walker and, consequently, there were some changes in the duration of gait phases, for instance longer of support phase (p = 0.0174). The muscle activation pattern for the analyzed group did not show statistically significant difference (onset VM: p= 0.4999; offset VM: p= 0.5647; onset BF: p= 0.1186; offset BF: p= 0.7823; onset TA: p= 0.5833; offset TA: p= 0.8393; onset GM: p= 0.6077; offset GM: p= 0.1429).. However, assessing the muscle activation pattern individually, some benefic changes can be noted, for example, the reduced co-activation between tibialis anterior and gastrocnemius medial. The results of evaluations through GAS (54.8) and SUS (81.4) about the use of the AROW showed good acceptance among users, and the desired results during the use of the walker were achieved. The fast adaptation, easiness of use and feeling of safety when using the device are positive points that were obtained using the AROW.O Acidente Vascular Cerebral (AVC) é uma das principais causas de prejuízos ao sistema neuromuscular. Dispositivos Robóticos vêm sendo amplamente desenvolvidos e estudados com a finalidade de serem utilizados na assistência à marcha e para o treinamento da marcha durante a reabilitação. O objetivo deste trabalho é avaliar a marcha assistida pelo AROW (Assistive Robotic Walker) em indivíduos hemiparéticos pós-AVC, através da análise de sinais de acelerometria e sinais mioelétricos de superfície (sEMG) provenientes dos músculos vasto medial (VM), bíceps femoral (BF), tibial anterior (TA) e gastrocnêmio medial (GM), e também utilizando os métodos de avaliação GAS (Goal Attainment Scaling) e SUS (System Usability Scale). Nove indivíduos hemiparéticos participaram dos testes. A velocidade da marcha foi reduzida com o uso do AROW e, consequentemente, houve algumas alterações na duração das fases da marcha, por exemplo, uma maior duração da fase de apoio (p = 0,0174). O padrão de ativação muscular para o grupo analisado não apresentou diferença estatisticamente significativa (início da ativação VM: p= 0,4999; término da ativação VM: p= 0,5647; início BF: p= 0,1186; término BF: p= 0,7823; início TA: p= 0,5833; término TA: p= 0,8393; início GM: p= 0,6077; término GM: p= 0,1429). Entretanto, avaliando o padrão de ativação muscular individualmente, podem-se notar algumas alterações benéficas, por exemplo, redução da coativação dos músculos tibial anterior e gastrocnêmio medial. Os resultados das avaliações através do GAS (54,8) e SUS (81,4) sobre o uso do AROW mostraram boa aceitação pelos usuários, e os objetivos esperados durante o uso do andador foram atingidos. A adaptação rápida, facilidade de utilização e sentimento de segurança ao usar o dispositivo são pontos positivos obtidos com o uso do AROW.Texthttp://repositorio.ufes.br/handle/10/1471porUniversidade Federal do Espírito SantoMestrado em BiotecnologiaPrograma de Pós-Graduação em BiotecnologiaUFESBRCentro de Ciências da SaúdeAcidente vascular cerebralEletromiografiaMétodo de avaliaçãoMarcha hemiparéticaAndador robóticoEletromiografia de superfícieAcelerômetroBiotecnologia61Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robóticoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)instname:Universidade Federal do Espírito Santo (UFES)instacron:UFESORIGINALAnálise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico.pdfAnálise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico.pdfTexto completoapplication/pdf3323589http://repositorio.ufes.br/bitstreams/753ec188-a43d-4928-af35-debe539eb241/download66acf0b992631a97d58c6a48254bba01MD51CC-LICENSElicense_urllicense_urltext/plain; charset=utf-849http://repositorio.ufes.br/bitstreams/cad3db58-fbc3-4e38-86ea-116bf9f6bc38/download4afdbb8c545fd630ea7db775da747b2fMD52license_textlicense_texttext/html; charset=utf-821326http://repositorio.ufes.br/bitstreams/b00573ce-940e-4daa-bc8c-a1f01cdc20c1/download3ece24ca8606da559a21ffc79b7a9f85MD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-823148http://repositorio.ufes.br/bitstreams/0bc441f5-f97e-45f7-a4de-cd62aef16bf2/download9da0b6dfac957114c6a7714714b86306MD54LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.ufes.br/bitstreams/3d351cee-e163-4237-8dae-34af7c4d312e/download8a4605be74aa9ea9d79846c1fba20a33MD5510/14712024-06-27 11:00:13.427oai:repositorio.ufes.br:10/1471http://repositorio.ufes.brRepositório InstitucionalPUBhttp://repositorio.ufes.br/oai/requestopendoar:21082024-06-27T11:00:13Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)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
dc.title.none.fl_str_mv Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
title Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
spellingShingle Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
Loterio, Flávia Aparecida
Biotecnologia
Acidente vascular cerebral
Eletromiografia
Método de avaliação
Marcha hemiparética
Andador robótico
Eletromiografia de superfície
Acelerômetro
61
title_short Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
title_full Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
title_fullStr Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
title_full_unstemmed Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
title_sort Análise do padrão de ativação muscular de indivíduos hemiparéticos pós-AVC em marcha assistida por andador robótico
author Loterio, Flávia Aparecida
author_facet Loterio, Flávia Aparecida
author_role author
dc.contributor.advisor-co1.fl_str_mv Frizera Neto, Anselmo
dc.contributor.advisor1.fl_str_mv Bastos Filho, Teodiano Freire
dc.contributor.author.fl_str_mv Loterio, Flávia Aparecida
dc.contributor.referee1.fl_str_mv Andrade, Adriano de Oliveira
dc.contributor.referee2.fl_str_mv Nogueira, Breno Valentim
contributor_str_mv Frizera Neto, Anselmo
Bastos Filho, Teodiano Freire
Andrade, Adriano de Oliveira
Nogueira, Breno Valentim
dc.subject.cnpq.fl_str_mv Biotecnologia
topic Biotecnologia
Acidente vascular cerebral
Eletromiografia
Método de avaliação
Marcha hemiparética
Andador robótico
Eletromiografia de superfície
Acelerômetro
61
dc.subject.br-rjbn.none.fl_str_mv Acidente vascular cerebral
Eletromiografia
Método de avaliação
Marcha hemiparética
Andador robótico
Eletromiografia de superfície
Acelerômetro
dc.subject.udc.none.fl_str_mv 61
description Stroke is a leading cause of damages in the neuromuscular system. Robotic devices have been widely developed and studied in order to be used in gait assistance and gait training during the rehabilitation. The goal of this work is to evaluate the assisted gait by the AROW (Assistive Robotic Walker) in post stroke hemiparetic individuals through accelerometer signals and surface Electromyography (sEMG) analysis. The analyzed muscles are vastus medialis (VM), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius medialis (GM). Furthermore, the evaluation methods GAS (Goal Attainment Scaling) and SUS (System Usability Scale) were used. Nine hemiparetic subjects participate of the experiments. The gait speed was decreased using the walker and, consequently, there were some changes in the duration of gait phases, for instance longer of support phase (p = 0.0174). The muscle activation pattern for the analyzed group did not show statistically significant difference (onset VM: p= 0.4999; offset VM: p= 0.5647; onset BF: p= 0.1186; offset BF: p= 0.7823; onset TA: p= 0.5833; offset TA: p= 0.8393; onset GM: p= 0.6077; offset GM: p= 0.1429).. However, assessing the muscle activation pattern individually, some benefic changes can be noted, for example, the reduced co-activation between tibialis anterior and gastrocnemius medial. The results of evaluations through GAS (54.8) and SUS (81.4) about the use of the AROW showed good acceptance among users, and the desired results during the use of the walker were achieved. The fast adaptation, easiness of use and feeling of safety when using the device are positive points that were obtained using the AROW.
publishDate 2015
dc.date.submitted.none.fl_str_mv 2015-02-20
dc.date.accessioned.fl_str_mv 2015-08-14T21:06:31Z
dc.date.issued.fl_str_mv 2015-02-20
dc.date.available.fl_str_mv 2016-06-24T06:00:06Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufes.br/handle/10/1471
url http://repositorio.ufes.br/handle/10/1471
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv Text
dc.publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Mestrado em Biotecnologia
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Biotecnologia
dc.publisher.initials.fl_str_mv UFES
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Centro de Ciências da Saúde
publisher.none.fl_str_mv Universidade Federal do Espírito Santo
Mestrado em Biotecnologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
instname:Universidade Federal do Espírito Santo (UFES)
instacron:UFES
instname_str Universidade Federal do Espírito Santo (UFES)
instacron_str UFES
institution UFES
reponame_str Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
collection Repositório Institucional da Universidade Federal do Espírito Santo (riUfes)
bitstream.url.fl_str_mv http://repositorio.ufes.br/bitstreams/753ec188-a43d-4928-af35-debe539eb241/download
http://repositorio.ufes.br/bitstreams/cad3db58-fbc3-4e38-86ea-116bf9f6bc38/download
http://repositorio.ufes.br/bitstreams/b00573ce-940e-4daa-bc8c-a1f01cdc20c1/download
http://repositorio.ufes.br/bitstreams/0bc441f5-f97e-45f7-a4de-cd62aef16bf2/download
http://repositorio.ufes.br/bitstreams/3d351cee-e163-4237-8dae-34af7c4d312e/download
bitstream.checksum.fl_str_mv 66acf0b992631a97d58c6a48254bba01
4afdbb8c545fd630ea7db775da747b2f
3ece24ca8606da559a21ffc79b7a9f85
9da0b6dfac957114c6a7714714b86306
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da Universidade Federal do Espírito Santo (riUfes) - Universidade Federal do Espírito Santo (UFES)
repository.mail.fl_str_mv
_version_ 1804309131620777984