Use of automatic device for blood pressure measurement in children between 4 e 13 years

Detalhes bibliográficos
Autor(a) principal: Reis, Roberta Silveira dos
Data de Publicação: 2009
Outros Autores: Lamas, José Luiz Mendes
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Eletrônica de Enfermagem
Texto Completo: https://revistas.ufg.br/fen/article/view/33225
Resumo: This study was performed to verify the reliability of blood pressure values obtained in children with an automatic device. The objectives were to determine blood pressure values in brachial and radial arteries in children using the auscultatory method and the correct cuff width and compare them to values obtained in the same arteries with an automatic device. The subjects were children hospitalized in a school hospital in São Paulo state. It was used the wrist digital monitor Tech Line WS-501. The sample was composed of children with arm or wrist girth between 14 and 17 cm, adequate to a 6 cm width cuff.  One hundred children were examined. The mean systolic values were 1.38 mmHg higher when the automatic device was used. Inversely, the mean diastolic values were 1.22 mmHg higher with the auscultatory method. Tech Line WS-501 was adequate to clinical use, both in arm and wrist.
id UFG-13_b57ac32071429d39e33b00e733462ac0
oai_identifier_str oai:ojs.revistas.ufg.br:article/33225
network_acronym_str UFG-13
network_name_str Revista Eletrônica de Enfermagem
repository_id_str
spelling Use of automatic device for blood pressure measurement in children between 4 e 13 yearsUso del dispositivo automático de la medida de presión arterial en niños entre 4 y 13 añosUso de dispositivo automático de medida de pressão arterial em crianças entre 4 e 13 anosBlood pressure determinationPediatric nursingBlood pressure monitors.monitorsBlood pressure determinationPediatric nursingBlood pressure monitors.monitorsDeterminación de la presión sanguíneaEnfermería pediátricaMonitores de presión sanguíneaDeterminación de la presión sanguíneaEnfermería pediátricaMonitores de presión sanguíneaDeterminação da pressão arterialEnfermagem pediátricaMonitores de pressão arterialDeterminação da pressão arterialEnfermagem pediátricaMonitores de pressão arterialThis study was performed to verify the reliability of blood pressure values obtained in children with an automatic device. The objectives were to determine blood pressure values in brachial and radial arteries in children using the auscultatory method and the correct cuff width and compare them to values obtained in the same arteries with an automatic device. The subjects were children hospitalized in a school hospital in São Paulo state. It was used the wrist digital monitor Tech Line WS-501. The sample was composed of children with arm or wrist girth between 14 and 17 cm, adequate to a 6 cm width cuff.  One hundred children were examined. The mean systolic values were 1.38 mmHg higher when the automatic device was used. Inversely, the mean diastolic values were 1.22 mmHg higher with the auscultatory method. Tech Line WS-501 was adequate to clinical use, both in arm and wrist.Se trata de un estudio realizado para averiguar la fiabilidad de los valores obtenidos en la aferición de la presión arterial en niños con un instrumento automático de medida de presión arterial. Tiene como objetivos verificar los valores de la presión en las arterias braquiales y radiales de los niños para el método del auscultatório con el manguito de la anchura correcta y comparar los valores conseguidos en las mismas arterias por medio de un instrumento automático. La investigación se ha hecho con niños atendidos en un hospital del estado de São Paulo. Se ha utilizado el monitor digital de presión arterial de pulso Tech Line WS-501. La muestra se ha compuesto por niños cuya circunferencia del brazo o del puño oscila entre 14 y 17 centímetros de ancho, ajustada al uso de un manguito de 6 centímetros de anchura. Fueron evaluados 100 niños. Los valores de presión arterial sistólica conseguidos con el dispositivo automático son superiores en la columna de mercurio en 1.38 mmHg, en media. Ya en la presión arterial diastólica los valores conseguidos con el dispositivo de mercurio son superiores en 1.22 mmHg en media. Así, el dispositivo Tech Line WS-501 se muestra adecuado para el uso clínico.Estudo realizado para averiguar a confiabilidade de valores obtidos na aferição de pressão arterial em crianças com um aparelho automático de medida de pressão arterial. Tem como objetivos verificar os valores de pressão nas artérias braquial e radial de crianças pelo método auscultatório com o manguito de largura correta e compará-los aos valores obtidos nas mesmas artérias com instrumento automático. A pesquisa foi realizada com crianças atendidas em um hospital universitário do interior do estado de São Paulo. Utilizou-se o monitor digital de pressão arterial de pulso Tech Line WS-501. A amostra, de 100 crianças, compôs-se de crianças cuja circunferência do braço ou punho estava entre 14 e 17 cm, adequadas ao uso do manguito de 6 cm de largura. O aparelho foi utilizado seguindo suas especificações. Os valores da pressão arterial sistólica obtidos com o aparelho automático foram superiores à coluna de mercúrio em 1,38 mmHg, em média. Em relação à pressão arterial diastólica, os valores obtidos com o aparelho de mercúrio foram superiores ao aparelho digital em 1,22 mmHg, em média. Assim, o aparelho Tech Line WS-501 mostrou-se adequado para o uso clínico, desde que a circunferência destes membros esteja de acordo com as especificações do aparelho automático.Faculdade de Enfermagem da UFG2009-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ufg.br/fen/article/view/3322510.5216/ree.v11i4.33225Revista Eletrônica de Enfermagem; Vol. 11 No. 4 (2009); 794-800Revista Eletrônica de Enfermagem; v. 11 n. 4 (2009); 794-8001518-1944reponame:Revista Eletrônica de Enfermageminstname:Universidade Federal de Goiás (UFG)instacron:UFGporhttps://revistas.ufg.br/fen/article/view/33225/17569Reis, Roberta Silveira dosLamas, José Luiz Mendesinfo:eu-repo/semantics/openAccess2020-08-11T00:34:07Zoai:ojs.revistas.ufg.br:article/33225Revistahttps://revistas.ufg.br/fenPUBhttps://revistas.ufg.br/fen/oairee.fen@ufg.br1518-19441518-1944opendoar:2020-08-11T00:34:07Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG)false
dc.title.none.fl_str_mv Use of automatic device for blood pressure measurement in children between 4 e 13 years
Uso del dispositivo automático de la medida de presión arterial en niños entre 4 y 13 años
Uso de dispositivo automático de medida de pressão arterial em crianças entre 4 e 13 anos
title Use of automatic device for blood pressure measurement in children between 4 e 13 years
spellingShingle Use of automatic device for blood pressure measurement in children between 4 e 13 years
Reis, Roberta Silveira dos
Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
title_short Use of automatic device for blood pressure measurement in children between 4 e 13 years
title_full Use of automatic device for blood pressure measurement in children between 4 e 13 years
title_fullStr Use of automatic device for blood pressure measurement in children between 4 e 13 years
title_full_unstemmed Use of automatic device for blood pressure measurement in children between 4 e 13 years
title_sort Use of automatic device for blood pressure measurement in children between 4 e 13 years
author Reis, Roberta Silveira dos
author_facet Reis, Roberta Silveira dos
Lamas, José Luiz Mendes
author_role author
author2 Lamas, José Luiz Mendes
author2_role author
dc.contributor.author.fl_str_mv Reis, Roberta Silveira dos
Lamas, José Luiz Mendes
dc.subject.por.fl_str_mv Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
topic Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Blood pressure determination
Pediatric nursing
Blood pressure monitors.monitors
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinación de la presión sanguínea
Enfermería pediátrica
Monitores de presión sanguínea
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
Determinação da pressão arterial
Enfermagem pediátrica
Monitores de pressão arterial
description This study was performed to verify the reliability of blood pressure values obtained in children with an automatic device. The objectives were to determine blood pressure values in brachial and radial arteries in children using the auscultatory method and the correct cuff width and compare them to values obtained in the same arteries with an automatic device. The subjects were children hospitalized in a school hospital in São Paulo state. It was used the wrist digital monitor Tech Line WS-501. The sample was composed of children with arm or wrist girth between 14 and 17 cm, adequate to a 6 cm width cuff.  One hundred children were examined. The mean systolic values were 1.38 mmHg higher when the automatic device was used. Inversely, the mean diastolic values were 1.22 mmHg higher with the auscultatory method. Tech Line WS-501 was adequate to clinical use, both in arm and wrist.
publishDate 2009
dc.date.none.fl_str_mv 2009-12-31
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistas.ufg.br/fen/article/view/33225
10.5216/ree.v11i4.33225
url https://revistas.ufg.br/fen/article/view/33225
identifier_str_mv 10.5216/ree.v11i4.33225
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://revistas.ufg.br/fen/article/view/33225/17569
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Faculdade de Enfermagem da UFG
publisher.none.fl_str_mv Faculdade de Enfermagem da UFG
dc.source.none.fl_str_mv Revista Eletrônica de Enfermagem; Vol. 11 No. 4 (2009); 794-800
Revista Eletrônica de Enfermagem; v. 11 n. 4 (2009); 794-800
1518-1944
reponame:Revista Eletrônica de Enfermagem
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Revista Eletrônica de Enfermagem
collection Revista Eletrônica de Enfermagem
repository.name.fl_str_mv Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv ree.fen@ufg.br
_version_ 1797049169720901632