Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte

Detalhes bibliográficos
Autor(a) principal: BARBOSA, Larissa Silva
Data de Publicação: 2011
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFG
Texto Completo: http://repositorio.bc.ufg.br/tede/handle/tde/1515
Resumo: The aim of this study was to assess body composition and anthropometry of the elderly with regard to agreement between methods, development and validation of predictive equations and cutoffs. We evaluated 132 elderly patients (52 men and 80 women) aged between 60 and 91 years, users of primary health care, not institutionalized and drawn at random in proportion to the nine health districts of Goiânia, GO. For collection of anthropometric measurements, bioelectrical impedance (BIA) and dual energy x-ray absorptiometry (DEXA), standardized procedures were used by trained examiners and equipment was calibrated regularly. Analyses were performed using STATA/SE. Descriptive analysis, tests for comparison of means, equation validation according to criteria suggested by Lohman, Bland-Altman and Lin graphic analysis and ROC (receiver operator characteristic curve) analysis were carried out. The project was approved by the Ethics Committee of the Federal University of Goias. The Durnin and Womersley equation showed the highest concordance correlation coefficient (CCC = 0.846) and the lowest mean differences (MD = - 2.335) for males. The equations of Lean et al. (for men) and Deurenberg et al. (for women) showed the highest correlation with and lowest mean differences from DEXA. Equations were proposed to estimate body fat percentage (BF%): (males: BF% = - 16.868 + 0.571TSF + 0.409WC and females: BF% = 8.634 + 0.601BMI + 0.321SISF + 0.234SSSF + 0.398TSF 0.467BSF). In both sexes, the equations are similar to DEXA in estimating BF% with high precision and accuracy. In males, the proposed body mass index (BMI) cutoff point was ≥ 25 kg/m2; the waist circumference (WC) cutoff point was ≥ 98.9 cm. In women, the BMI and WC values with the most sensitivity, specificity and accuracy were ≥ 26.6 kg/m2 and ≥ 90.5 cm. Since the currently available equations for predicting body composition of elderly have certain limitations, these newly developed and validated equations for the two sexes can be recommended for wide use. Accurate BMI and WC cutoff points for predicting BF% in older adults were also identified.
id UFG-2_e64406e6e1f10566fe13e76f8d3ee921
oai_identifier_str oai:repositorio.bc.ufg.br:tde/1515
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling SILVEIRA, Erika Aparecida dahttp://lattes.cnpq.br/3801865783333828http://lattes.cnpq.br/1848770391766760BARBOSA, Larissa Silva2014-07-29T15:25:15Z2011-12-082011-05-09BARBOSA, Larissa Silva. Body composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.. 2011. 232 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.http://repositorio.bc.ufg.br/tede/handle/tde/1515The aim of this study was to assess body composition and anthropometry of the elderly with regard to agreement between methods, development and validation of predictive equations and cutoffs. We evaluated 132 elderly patients (52 men and 80 women) aged between 60 and 91 years, users of primary health care, not institutionalized and drawn at random in proportion to the nine health districts of Goiânia, GO. For collection of anthropometric measurements, bioelectrical impedance (BIA) and dual energy x-ray absorptiometry (DEXA), standardized procedures were used by trained examiners and equipment was calibrated regularly. Analyses were performed using STATA/SE. Descriptive analysis, tests for comparison of means, equation validation according to criteria suggested by Lohman, Bland-Altman and Lin graphic analysis and ROC (receiver operator characteristic curve) analysis were carried out. The project was approved by the Ethics Committee of the Federal University of Goias. The Durnin and Womersley equation showed the highest concordance correlation coefficient (CCC = 0.846) and the lowest mean differences (MD = - 2.335) for males. The equations of Lean et al. (for men) and Deurenberg et al. (for women) showed the highest correlation with and lowest mean differences from DEXA. Equations were proposed to estimate body fat percentage (BF%): (males: BF% = - 16.868 + 0.571TSF + 0.409WC and females: BF% = 8.634 + 0.601BMI + 0.321SISF + 0.234SSSF + 0.398TSF 0.467BSF). In both sexes, the equations are similar to DEXA in estimating BF% with high precision and accuracy. In males, the proposed body mass index (BMI) cutoff point was ≥ 25 kg/m2; the waist circumference (WC) cutoff point was ≥ 98.9 cm. In women, the BMI and WC values with the most sensitivity, specificity and accuracy were ≥ 26.6 kg/m2 and ≥ 90.5 cm. Since the currently available equations for predicting body composition of elderly have certain limitations, these newly developed and validated equations for the two sexes can be recommended for wide use. Accurate BMI and WC cutoff points for predicting BF% in older adults were also identified.O objetivo deste estudo foi analisar a composição corporal e antropometria de idosos com relação à concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte. Foram avaliados 132 idosos (52 homens e 80 mulheres), com idade entre 60 e 91 anos, usuários da atenção primária à saúde, não instituicionalizados, selecionados a partir de sorteio aleatório proporcional aos nove distritos sanitários de Goiânia-GO. Para coleta de medidas antropométricas, impedância bioelétrica (BIA) e absortometria por raio-X de dupla energia (DEXA) foram utilizados procedimentos padronizados, por avaliadores devidamente treinados, com equipamentos regularmente calibrados. As análises foram realizadas no STATA/SE. Realizou-se análise descritiva, testes para comparação de médias, validação de equações segundo critérios sugeridos por Lohman, análise gráfica por Bland e Altman e por Lin e análise de Curva ROC (receiver operator characteristic curve). O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal de Goiás. A equação de Durnin e Womersley apresentou maior coeficiente de correlação de concordância (CCC = 0,846) e menor diferenças médias (DM = - 2,335) para o sexo masculino. A equação de Lean et al. (para homens) e de Deurenberg et al. (para mulheres) apresentaram maior concordância e menores diferenças médias com DEXA. Foram propostas equações para estimativa do percentual de gordura corporal (%GC): (sexo masculino: %GC = - 16,868 + 0,571DCTR + 0,409CC e sexo feminino: %GC = 8,634 + 0,601IMC + 0,321DCSI + 0,234DCSE + 0,398DCTR 0,467DCBI). Em ambos os sexos, as equações propostas apresentaram semelhança com DEXA na estimativa do %GC, apresentando alta precisão e acurácia. No sexo masculino o ponto de corte proposto para índice de massa corporal (IMC) foi ≥ 25 Kg/m2 e para circunferência da cintura (CC) ≥ 98,9 cm. Nas mulheres os valores de IMC e CC com maior sensibilidade, especificidade e acurácia foram ≥ 26,6 Kg/m2 e ≥ 90,5 cm. As equações atualmentes disponíveis para predizer a composição corporal de idosos apresentam limitações, sendo desenvolvida e validada nova equação para ambos os sexos a qual recomenda-se sua ampla utilização. Identificou-se ainda pontos de corte acurados de IMC e CC para predizer %GC em idosos.Made available in DSpace on 2014-07-29T15:25:15Z (GMT). No. of bitstreams: 1 Tese Larissa Silva Barbosa.pdf: 4706638 bytes, checksum: 84142955db2151a63ddb14705543d0e3 (MD5) Previous issue date: 2011-05-09application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/4373/Tese%20Larissa%20Silva%20Barbosa.pdf.jpgporUniversidade Federal de GoiásDoutorado em Ciencias da SaudeUFGBRCiencias da SaudeComposição corporalIdosoAntropometriaImpedância elétricaAbsortometria por raio-X de dulpa energiaEstudos de ValidaçãoÍndice de massa corporalCircunferência da cinturaPregas cutâneas1.Composição corporal; 2.Antropometria; 3.Idosos; 4.Estudos de Validação; 5.EpidemiologiaBody compositionAgedAnthropometryElectric impedanceDual-Energy X-Ray AbsorptiometryValidation studiesBody mass indexCNPQ::CIENCIAS DA SAUDEComposição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corteBody composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALTese Larissa Silva Barbosa.pdfapplication/pdf4706638http://repositorio.bc.ufg.br/tede/bitstreams/5af2027c-9526-4207-bf25-8c4ca55d0895/download84142955db2151a63ddb14705543d0e3MD51TEXTTese Larissa Silva Barbosa.pdf.txtTese Larissa Silva Barbosa.pdf.txtExtracted Texttext/plain417138http://repositorio.bc.ufg.br/tede/bitstreams/b758be7f-dd49-4319-b2fa-ce22399a8dc1/downloadab09c20042abc4cf8c94bf6ea0c7a683MD52THUMBNAILTese Larissa Silva Barbosa.pdf.jpgTese Larissa Silva Barbosa.pdf.jpgGenerated Thumbnailimage/jpeg2944http://repositorio.bc.ufg.br/tede/bitstreams/6bd4351e-b53d-4d37-a378-ca7746dbb9cc/download88dc4e822e3a6fc323e1cb9cb10e7539MD53tde/15152014-07-30 03:13:40.009open.accessoai:repositorio.bc.ufg.br:tde/1515http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:13:40Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false
dc.title.por.fl_str_mv Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
dc.title.alternative.eng.fl_str_mv Body composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.
title Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
spellingShingle Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
BARBOSA, Larissa Silva
Composição corporal
Idoso
Antropometria
Impedância elétrica
Absortometria por raio-X de dulpa energia
Estudos de Validação
Índice de massa corporal
Circunferência da cintura
Pregas cutâneas
1.Composição corporal; 2.Antropometria; 3.Idosos; 4.Estudos de Validação; 5.Epidemiologia
Body composition
Aged
Anthropometry
Electric impedance
Dual-Energy X-Ray Absorptiometry
Validation studies
Body mass index
CNPQ::CIENCIAS DA SAUDE
title_short Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
title_full Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
title_fullStr Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
title_full_unstemmed Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
title_sort Composição corporal e antropometria de idosos:concordância entre métodos, desenvolvimento e validação de equações preditivas e pontos de corte
author BARBOSA, Larissa Silva
author_facet BARBOSA, Larissa Silva
author_role author
dc.contributor.advisor1.fl_str_mv SILVEIRA, Erika Aparecida da
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3801865783333828
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/1848770391766760
dc.contributor.author.fl_str_mv BARBOSA, Larissa Silva
contributor_str_mv SILVEIRA, Erika Aparecida da
dc.subject.por.fl_str_mv Composição corporal
Idoso
Antropometria
Impedância elétrica
Absortometria por raio-X de dulpa energia
Estudos de Validação
Índice de massa corporal
Circunferência da cintura
Pregas cutâneas
1.Composição corporal; 2.Antropometria; 3.Idosos; 4.Estudos de Validação; 5.Epidemiologia
topic Composição corporal
Idoso
Antropometria
Impedância elétrica
Absortometria por raio-X de dulpa energia
Estudos de Validação
Índice de massa corporal
Circunferência da cintura
Pregas cutâneas
1.Composição corporal; 2.Antropometria; 3.Idosos; 4.Estudos de Validação; 5.Epidemiologia
Body composition
Aged
Anthropometry
Electric impedance
Dual-Energy X-Ray Absorptiometry
Validation studies
Body mass index
CNPQ::CIENCIAS DA SAUDE
dc.subject.eng.fl_str_mv Body composition
Aged
Anthropometry
Electric impedance
Dual-Energy X-Ray Absorptiometry
Validation studies
Body mass index
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE
description The aim of this study was to assess body composition and anthropometry of the elderly with regard to agreement between methods, development and validation of predictive equations and cutoffs. We evaluated 132 elderly patients (52 men and 80 women) aged between 60 and 91 years, users of primary health care, not institutionalized and drawn at random in proportion to the nine health districts of Goiânia, GO. For collection of anthropometric measurements, bioelectrical impedance (BIA) and dual energy x-ray absorptiometry (DEXA), standardized procedures were used by trained examiners and equipment was calibrated regularly. Analyses were performed using STATA/SE. Descriptive analysis, tests for comparison of means, equation validation according to criteria suggested by Lohman, Bland-Altman and Lin graphic analysis and ROC (receiver operator characteristic curve) analysis were carried out. The project was approved by the Ethics Committee of the Federal University of Goias. The Durnin and Womersley equation showed the highest concordance correlation coefficient (CCC = 0.846) and the lowest mean differences (MD = - 2.335) for males. The equations of Lean et al. (for men) and Deurenberg et al. (for women) showed the highest correlation with and lowest mean differences from DEXA. Equations were proposed to estimate body fat percentage (BF%): (males: BF% = - 16.868 + 0.571TSF + 0.409WC and females: BF% = 8.634 + 0.601BMI + 0.321SISF + 0.234SSSF + 0.398TSF 0.467BSF). In both sexes, the equations are similar to DEXA in estimating BF% with high precision and accuracy. In males, the proposed body mass index (BMI) cutoff point was ≥ 25 kg/m2; the waist circumference (WC) cutoff point was ≥ 98.9 cm. In women, the BMI and WC values with the most sensitivity, specificity and accuracy were ≥ 26.6 kg/m2 and ≥ 90.5 cm. Since the currently available equations for predicting body composition of elderly have certain limitations, these newly developed and validated equations for the two sexes can be recommended for wide use. Accurate BMI and WC cutoff points for predicting BF% in older adults were also identified.
publishDate 2011
dc.date.available.fl_str_mv 2011-12-08
dc.date.issued.fl_str_mv 2011-05-09
dc.date.accessioned.fl_str_mv 2014-07-29T15:25:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv BARBOSA, Larissa Silva. Body composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.. 2011. 232 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tde/1515
identifier_str_mv BARBOSA, Larissa Silva. Body composition and anthropometry of the elderly:agreement between methods, development and validation of predictive equations and cutoffs.. 2011. 232 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.
url http://repositorio.bc.ufg.br/tede/handle/tde/1515
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Doutorado em Ciencias da Saude
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciencias da Saude
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/5af2027c-9526-4207-bf25-8c4ca55d0895/download
http://repositorio.bc.ufg.br/tede/bitstreams/b758be7f-dd49-4319-b2fa-ce22399a8dc1/download
http://repositorio.bc.ufg.br/tede/bitstreams/6bd4351e-b53d-4d37-a378-ca7746dbb9cc/download
bitstream.checksum.fl_str_mv 84142955db2151a63ddb14705543d0e3
ab09c20042abc4cf8c94bf6ea0c7a683
88dc4e822e3a6fc323e1cb9cb10e7539
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1798044385595621376