CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.

Detalhes bibliográficos
Autor(a) principal: SOARES, Fernanda Lima
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFMA
Texto Completo: https://tedebc.ufma.br/jspui/handle/tede/tede/3036
Resumo: Introduction: The determination of the arterial occlusion of pressure (AOP) is a critical measurement for selection of adequate pressures to the BFR method. Effective restriction pressures (usually 40-50% of the AOP) could be selected to be used in association with muscle contractions against minor resistance, when the main purpose is gaining mass. Recently doppler hand-held equipment have been utilized for such purpose, on the other hand, pulse oximeter has been largely utilized in the clinical practice for monitoring the hemoglobin saturation and the blood flow inside the capillary bed, via laser diode sensors. Both methods are capable to detect the presence or absence of blood flow but they never have been tested before, in regards to its use to predict the AOP. Objective: Verify the agreement between doppler and pulse oximeter occlusion in measuring arterial occlusion pressure. Materials Methods: The sample consisted of 70 subjects (37 women and 33 men), aged 18 to 33 years. The assessments were made in a single session composed by anthropometric measures, response to Physical Activity Readiness Questionnaire (PAR-Q) and International Physical Activity Questionnaire (IPAQ) followed for the blinded and simultaneously determination of arterial occlusion pressure with doppler and pulse oximeter in the siting, standing and lying positions. Results: The results showed an excellent agreement Kappa between methods in the three positions analyzed, seated, standing and lying, respectively (0.963, 0.967, 1.00) and very strong Spearman’s correlation (rs= 0.997, 0.992, 0,993). Discussion: Arterial occlusion pressure (AOP) measure is determinant for the effectiveness and safety execution of blood flow restriction protocols associated or not with exercise. Currently the literature available suggest the use of doppler handheld for the precise measurement of AOP however it’s a hospital equipment with specific technical manipulations demands, a higher cost besides depends to the specific moment of silencing arterial pulse which could be very hard in many times. In instance we propose the use of the pulse oximeter, a lower cost and easier to manipulate equipment that show an excellent agreement with the gold standard to access the AOP, making possible to coaches in physical education and all community the use of methods of blood flow restriction on non-laboratory environments. Conclusion: The pulse oximeter has been shown to be effective in comparison to doppler handheld to access the AOP. It can be adopted as an instrument to facilitate the achievement of this measure in academic, professional and leisure environments allowing the practice of techniques of blood flow restriction even safer, more efficient and accessible.
id UFMA_fefbcd6d7990c06e17f29746879de994
oai_identifier_str oai:tede2:tede/3036
network_acronym_str UFMA
network_name_str Biblioteca Digital de Teses e Dissertações da UFMA
repository_id_str 2131
spelling ZANCHI, Nelo Eidy273.065.498-47http://lattes.cnpq.br/2360408543467916CABIDO, Christian Emmanuel Torres068.685.006-88http://lattes.cnpq.br/9102119601757395ZANHI, Nelo Eidy273.065.498-47http://lattes.cnpq.br/2360408543467916CABIDO, Christian Emmanuel Torres068.685.006-88http://lattes.cnpq.br/9102119601757395MENDES, Thiago Teixeirahttp://lattes.cnpq.br/1989081286274816PIRES, Flávio de Oliveirahttp://lattes.cnpq.br/0352012377134530033.228.731-96http://lattes.cnpq.br/5121202522989567SOARES, Fernanda Lima2020-02-04T15:57:43Z2018-07-12SOARES, Fernanda Lima. Concordância entre doppler portátil e oxímetro de pulso na determinação da pressão arterial de oclusão de jovens saudáveis.. 2018. 86 folhas. Dissertação( Programa de Pós-Graduação em Educação Física) - Universidade Federal do Maranhão, São Luís, 2018.https://tedebc.ufma.br/jspui/handle/tede/tede/3036Introduction: The determination of the arterial occlusion of pressure (AOP) is a critical measurement for selection of adequate pressures to the BFR method. Effective restriction pressures (usually 40-50% of the AOP) could be selected to be used in association with muscle contractions against minor resistance, when the main purpose is gaining mass. Recently doppler hand-held equipment have been utilized for such purpose, on the other hand, pulse oximeter has been largely utilized in the clinical practice for monitoring the hemoglobin saturation and the blood flow inside the capillary bed, via laser diode sensors. Both methods are capable to detect the presence or absence of blood flow but they never have been tested before, in regards to its use to predict the AOP. Objective: Verify the agreement between doppler and pulse oximeter occlusion in measuring arterial occlusion pressure. Materials Methods: The sample consisted of 70 subjects (37 women and 33 men), aged 18 to 33 years. The assessments were made in a single session composed by anthropometric measures, response to Physical Activity Readiness Questionnaire (PAR-Q) and International Physical Activity Questionnaire (IPAQ) followed for the blinded and simultaneously determination of arterial occlusion pressure with doppler and pulse oximeter in the siting, standing and lying positions. Results: The results showed an excellent agreement Kappa between methods in the three positions analyzed, seated, standing and lying, respectively (0.963, 0.967, 1.00) and very strong Spearman’s correlation (rs= 0.997, 0.992, 0,993). Discussion: Arterial occlusion pressure (AOP) measure is determinant for the effectiveness and safety execution of blood flow restriction protocols associated or not with exercise. Currently the literature available suggest the use of doppler handheld for the precise measurement of AOP however it’s a hospital equipment with specific technical manipulations demands, a higher cost besides depends to the specific moment of silencing arterial pulse which could be very hard in many times. In instance we propose the use of the pulse oximeter, a lower cost and easier to manipulate equipment that show an excellent agreement with the gold standard to access the AOP, making possible to coaches in physical education and all community the use of methods of blood flow restriction on non-laboratory environments. Conclusion: The pulse oximeter has been shown to be effective in comparison to doppler handheld to access the AOP. It can be adopted as an instrument to facilitate the achievement of this measure in academic, professional and leisure environments allowing the practice of techniques of blood flow restriction even safer, more efficient and accessible.Introdução: A determinação da pressão de oclusão arterial (POA) é uma medida crítica para seleção da pressão adequada a ser utilizada nos métodos baseados na restrição de fluxo sanguíneo. A pressão considerada efetiva nesses métodos de treinamento com restrição do fluxo sanguíneo está em torno 40 a 80% da POA. Recentemente o equipamento de doppler portátil tem sido utilizado para realizar essa medida, enquanto o oxímetro de pulso vem sendo largamente utilizado na prática clínica para medida constante e não invasiva da saturação de oxigênio sanguíneo. Ambos os métodos têm a capacidade de detectar a presença ou ausência de pulso sanguíneo, entretanto, o oxímetro de pulso não foi testado anteriormente na medição da POA. Objetivo: Verificar a concordância entre doppler portátil e oxímetro de pulso na determinação da pressão de oclusão arterial. Material e Métodos: A amostra foi composta por 70 sujeitos (37 mulheres e 33 homens), eutróficos e normotensos, com idade de 18 a 33 anos. Os sujeitos foram avaliados em sessão única através de avaliação antropométrica, resposta aos questionários PAR-Q (prontidão para atividade física) e IPAQ (nível de atividade física) com posterior avaliação simultânea e blindada da pressão arterial de oclusão via doppler e oxímetro de pulso, de maneira aleatória nas posições sentado, em pé e deitado. Resultados: Os resultados demostraram acordo excelente entre os métodos através do coeficiente Kappa nas três posições sendo Ƙ=0,963 (sentado); Ƙ=0,967 (em pé); e Ƙ=1,00 (deitado), e correlação de Spearman muito forte e positiva, também das três posições, sendo rs=0,997 (sentado); rs=0,992 (em pé); rs=0,993 (deitado). Discussão: A medida da pressão arterial de oclusão é critério determinante para a execução precisa e segura de protocolos de restrição de fluxo sanguíneo associados ou não ao exercício físico. Atualmente a literatura nos sugere a utilização do recurso do Doppler portátil para medida precisa da POA, entretanto, se trata de equipamento de ambiente hospitalar que exige manipulação técnica específica precisa e de alto custo, além de depender do silenciamento dos sinais sonoros da pulsação sanguínea que em muitos momentos pode ser gradativo ou até mesmo inaudível, necessitando medidas repetidas até sua determinação, distanciando sua utilização da prática e tornando o acesso à metodologia de restrição de fluxo sanguíneo por muitas vezes restrito ao ambiente científico. Nesse sentido, propomos a utilização do oxímetro de pulso como metodologia financeiramente acessível, de fácil aplicação e determinação pontual devido a sua expressão visual e excelente acordo com o equipamento mais utilizado para tal medida, a fim de disponibilizar a determinação da POA aos profissionais de saúde e contribuir para a popularização dos métodos de restrição de fluxo sanguíneo em âmbito não-laboratorial. Conclusão: O oxímetro de pulso demonstrou ser eficaz em medir a POA em comparação ao doppler portátil, podendo, então, ser adotado como instrumento facilitador da realização dessa medida em ambientes acadêmicos, profissionais e de lazer permitindo a prática e técnicas de restrição de fluxo sanguíneo segura, eficiente e acessível.Submitted by Maria Aparecida (cidazen@gmail.com) on 2020-02-04T15:57:43Z No. of bitstreams: 1 Fernanda Lima Soares.pdf: 1245173 bytes, checksum: e7087a50f3c2f7445b7fe49177b3bede (MD5)Made available in DSpace on 2020-02-04T15:57:43Z (GMT). No. of bitstreams: 1 Fernanda Lima Soares.pdf: 1245173 bytes, checksum: e7087a50f3c2f7445b7fe49177b3bede (MD5) Previous issue date: 2018-07-12FAPEMAapplication/pdfporUniversidade Federal do MaranhãoPROGRAMA DE PÓS-GRADUACAO EM EDUCAÇÃO FÍSICAUFMABrasilDEPARTAMENTO DE EDUCAÇÃO FÍSICA/CCBSTreinamento de força com restrição de fluxo sanguíneo;oxímetro de pulso;exercícioexercise;Blood flow restriction training;pulse oximeter;Educação FísicaCONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.AGREEMENT BETWEEN PORTABLE DOPPLER AND OXIMETER PULSE IN DETERMINING OCCLUSION BLOOD PRESSURE HEALTHY YOUNG PEOPLE.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UFMAinstname:Universidade Federal do Maranhão (UFMA)instacron:UFMAORIGINALFernanda Lima Soares.pdfFernanda Lima Soares.pdfapplication/pdf1245173http://tedebc.ufma.br:8080/bitstream/tede/3036/2/Fernanda+Lima+Soares.pdfe7087a50f3c2f7445b7fe49177b3bedeMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82255http://tedebc.ufma.br:8080/bitstream/tede/3036/1/license.txt97eeade1fce43278e63fe063657f8083MD51tede/30362020-02-04 12:57:43.032oai:tede2:tede/3036IExJQ0VOw4dBIERFIERJU1RSSUJVScOHw4NPIE7Dg08tRVhDTFVTSVZBCgpDb20gYSBhcHJlc2VudGHDp8OjbyBkZXN0YSBsaWNlbsOnYSxvIGF1dG9yIChlcykgb3UgbyB0aXR1bGFyIGRvcyBkaXJlaXRvcyBkZSBhdXRvciBjb25jZWRlIMOgIFVuaXZlcnNpZGFkZSBGZWRlcmFsIGRvIE1hcmFuaMOjbyAoVUZNQSkgbyBkaXJlaXRvIG7Do28tZXhjbHVzaXZvIGRlIHJlcHJvZHV6aXIsIHRyYWR1emlyIChjb25mb3JtZSBkZWZpbmlkbyBhYmFpeG8pLCBlL291IGRpc3RyaWJ1aXIgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YcOnw6NvIChpbmNsdWluZG8gbyByZXN1bW8pIHBvciB0b2RvIG8gbXVuZG8gbm8gZm9ybWF0byBpbXByZXNzbyBlIGVsZXRyw7RuaWNvIGUgZW0gcXVhbHF1ZXIgbWVpbywgaW5jbHVpbmRvIG9zIGZvcm1hdG9zIMOhdWRpbyBvdSB2w61kZW8uCgpWb2PDqiBjb25jb3JkYSBxdWUgYSBVRk1BIHBvZGUsIHNlbSBhbHRlcmFyIG8gY29udGXDumRvLCB0cmFuc3BvciBhIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gcGFyYSBxdWFscXVlciBtZWlvIG91IGZvcm1hdG8gcGFyYSBmaW5zIGRlIHByZXNlcnZhw6fDo28uCgpWb2PDqiB0YW1iw6ltIGNvbmNvcmRhIHF1ZSBhIFVGTUEgcG9kZSBtYW50ZXIgbWFpcyBkZSB1bWEgY8OzcGlhIGRlIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gcGFyYSBmaW5zIGRlIHNlZ3VyYW7Dp2EsIGJhY2stdXAgZSBwcmVzZXJ2YcOnw6NvLgoKVm9jw6ogZGVjbGFyYSBxdWUgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YcOnw6NvIMOpIG9yaWdpbmFsIGUgcXVlIHZvY8OqIHRlbSBvIHBvZGVyIGRlIGNvbmNlZGVyIG9zIGRpcmVpdG9zIGNvbnRpZG9zIG5lc3RhIGxpY2Vuw6dhLiBWb2PDqiB0YW1iw6ltIGRlY2xhcmEgcXVlIG8gZGVww7NzaXRvIGRhIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gbsOjbywgcXVlIHNlamEgZGUgc2V1IGNvbmhlY2ltZW50bywgaW5mcmluZ2UgZGlyZWl0b3MgYXV0b3JhaXMgZGUgbmluZ3XDqW0uCgpDYXNvIGEgc3VhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbyBjb250ZW5oYSBtYXRlcmlhbCBxdWUgdm9jw6ogbsOjbyBwb3NzdWkgYSB0aXR1bGFyaWRhZGUgZG9zIGRpcmVpdG9zIGF1dG9yYWlzLCB2b2PDqiBkZWNsYXJhIHF1ZSBvYnRldmUgYSBwZXJtaXNzw6NvIGlycmVzdHJpdGEgZG8gZGV0ZW50b3IgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIHBhcmEgY29uY2VkZXIgw6AgVUZNQSBvcyBkaXJlaXRvcyBhcHJlc2VudGFkb3MgbmVzdGEgbGljZW7Dp2EsIGUgcXVlIGVzc2UgbWF0ZXJpYWwgZGUgcHJvcHJpZWRhZGUgZGUgdGVyY2Vpcm9zIGVzdMOhIGNsYXJhbWVudGUgaWRlbnRpZmljYWRvIGUgcmVjb25oZWNpZG8gbm8gdGV4dG8gb3Ugbm8gY29udGXDumRvIGRhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbyBvcmEgZGVwb3NpdGFkYS4KCkNBU08gQSBURVNFIE9VIERJU1NFUlRBw4fDg08gT1JBIERFUE9TSVRBREEgVEVOSEEgU0lETyBSRVNVTFRBRE8gREUgVU0gUEFUUk9Dw41OSU8gT1UgQVBPSU8gREUgVU1BIEFHw4pOQ0lBIERFIEZPTUVOVE8gT1UgT1VUUk8gT1JHQU5JU01PIFFVRSBOw4NPIFNFSkEgQSBVRk1BLCBWT0PDiiBERUNMQVJBIFFVRSBSRVNQRUlUT1UgVE9ET1MgRSBRVUFJU1FVRVIgRElSRUlUT1MgREUgUkVWSVPDg08gQ09NTyBUQU1Cw4lNIEFTIERFTUFJUyBPQlJJR0HDh8OVRVMgRVhJR0lEQVMgUE9SIENPTlRSQVRPIE9VIEFDT1JETy4KCkEgVUZNQSBzZSBjb21wcm9tZXRlIGEgaWRlbnRpZmljYXIgY2xhcmFtZW50ZSBvIHNldSBub21lIG91IG8ocykgbm9tZShzKSBkbyhzKSBkZXRlbnRvcihlcykgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIGRhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbywgZSBuw6NvIGZhcsOhIHF1YWxxdWVyIGFsdGVyYcOnw6NvLCBhbMOpbSBkYXF1ZWxhcyBjb25jZWRpZGFzIHBvciBlc3RhIGxpY2Vuw6dhLgoKRGVjbGFyYSB0YW1iw6ltIHF1ZSB0b2RhcyBhcyBhZmlsaWHDp8O1ZXMgY29ycG9yYXRpdmFzIG91IGluc3RpdHVjaW9uYWlzIGUgdG9kYXMgYXMgZm9udGVzIGRlIGFwb2lvIGZpbmFuY2Vpcm8gYW8gdHJhYmFsaG8gZXN0w6NvIGRldmlkYW1lbnRlIGNpdGFkYXMgb3UgbWVuY2lvbmFkYXMgZSBjZXJ0aWZpY2EgcXVlIG7Do28gaMOhIG5lbmh1bSBpbnRlcmVzc2UgY29tZXJjaWFsIG91IGFzc29jaWF0aXZvIHF1ZSByZXByZXNlbnRlIGNvbmZsaXRvIGRlIGludGVyZXNzZSBlbSBjb25leMOjbyBjb20gbyB0cmFiYWxobyBzdWJtZXRpZG8uCgoKCgoKCgo=Biblioteca Digital de Teses e Dissertaçõeshttps://tedebc.ufma.br/jspui/PUBhttp://tedebc.ufma.br:8080/oai/requestrepositorio@ufma.br||repositorio@ufma.bropendoar:21312020-02-04T15:57:43Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)false
dc.title.por.fl_str_mv CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
dc.title.alternative.por.fl_str_mv AGREEMENT BETWEEN PORTABLE DOPPLER AND OXIMETER PULSE IN DETERMINING OCCLUSION BLOOD PRESSURE HEALTHY YOUNG PEOPLE.
title CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
spellingShingle CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
SOARES, Fernanda Lima
Treinamento de força com restrição de fluxo sanguíneo;
oxímetro de pulso;
exercício
exercise;
Blood flow restriction training;
pulse oximeter;
Educação Física
title_short CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
title_full CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
title_fullStr CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
title_full_unstemmed CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
title_sort CONCORDÂNCIA ENTRE DOPPLER PORTÁTIL E OXÍMETRO DE PULSO NA DETERMINAÇÃO DA PRESSÃO ARTERIAL DE OCLUSÃO DE JOVENS SAUDÁVEIS.
author SOARES, Fernanda Lima
author_facet SOARES, Fernanda Lima
author_role author
dc.contributor.advisor1.fl_str_mv ZANCHI, Nelo Eidy
dc.contributor.advisor1ID.fl_str_mv 273.065.498-47
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/2360408543467916
dc.contributor.advisor-co1.fl_str_mv CABIDO, Christian Emmanuel Torres
dc.contributor.advisor-co1ID.fl_str_mv 068.685.006-88
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/9102119601757395
dc.contributor.referee1.fl_str_mv ZANHI, Nelo Eidy
dc.contributor.referee1ID.fl_str_mv 273.065.498-47
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/2360408543467916
dc.contributor.referee2.fl_str_mv CABIDO, Christian Emmanuel Torres
dc.contributor.referee2ID.fl_str_mv 068.685.006-88
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/9102119601757395
dc.contributor.referee3.fl_str_mv MENDES, Thiago Teixeira
dc.contributor.referee3Lattes.fl_str_mv http://lattes.cnpq.br/1989081286274816
dc.contributor.referee4.fl_str_mv PIRES, Flávio de Oliveira
dc.contributor.referee4Lattes.fl_str_mv http://lattes.cnpq.br/0352012377134530
dc.contributor.authorID.fl_str_mv 033.228.731-96
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/5121202522989567
dc.contributor.author.fl_str_mv SOARES, Fernanda Lima
contributor_str_mv ZANCHI, Nelo Eidy
CABIDO, Christian Emmanuel Torres
ZANHI, Nelo Eidy
CABIDO, Christian Emmanuel Torres
MENDES, Thiago Teixeira
PIRES, Flávio de Oliveira
dc.subject.por.fl_str_mv Treinamento de força com restrição de fluxo sanguíneo;
oxímetro de pulso;
exercício
exercise;
topic Treinamento de força com restrição de fluxo sanguíneo;
oxímetro de pulso;
exercício
exercise;
Blood flow restriction training;
pulse oximeter;
Educação Física
dc.subject.eng.fl_str_mv Blood flow restriction training;
pulse oximeter;
dc.subject.cnpq.fl_str_mv Educação Física
description Introduction: The determination of the arterial occlusion of pressure (AOP) is a critical measurement for selection of adequate pressures to the BFR method. Effective restriction pressures (usually 40-50% of the AOP) could be selected to be used in association with muscle contractions against minor resistance, when the main purpose is gaining mass. Recently doppler hand-held equipment have been utilized for such purpose, on the other hand, pulse oximeter has been largely utilized in the clinical practice for monitoring the hemoglobin saturation and the blood flow inside the capillary bed, via laser diode sensors. Both methods are capable to detect the presence or absence of blood flow but they never have been tested before, in regards to its use to predict the AOP. Objective: Verify the agreement between doppler and pulse oximeter occlusion in measuring arterial occlusion pressure. Materials Methods: The sample consisted of 70 subjects (37 women and 33 men), aged 18 to 33 years. The assessments were made in a single session composed by anthropometric measures, response to Physical Activity Readiness Questionnaire (PAR-Q) and International Physical Activity Questionnaire (IPAQ) followed for the blinded and simultaneously determination of arterial occlusion pressure with doppler and pulse oximeter in the siting, standing and lying positions. Results: The results showed an excellent agreement Kappa between methods in the three positions analyzed, seated, standing and lying, respectively (0.963, 0.967, 1.00) and very strong Spearman’s correlation (rs= 0.997, 0.992, 0,993). Discussion: Arterial occlusion pressure (AOP) measure is determinant for the effectiveness and safety execution of blood flow restriction protocols associated or not with exercise. Currently the literature available suggest the use of doppler handheld for the precise measurement of AOP however it’s a hospital equipment with specific technical manipulations demands, a higher cost besides depends to the specific moment of silencing arterial pulse which could be very hard in many times. In instance we propose the use of the pulse oximeter, a lower cost and easier to manipulate equipment that show an excellent agreement with the gold standard to access the AOP, making possible to coaches in physical education and all community the use of methods of blood flow restriction on non-laboratory environments. Conclusion: The pulse oximeter has been shown to be effective in comparison to doppler handheld to access the AOP. It can be adopted as an instrument to facilitate the achievement of this measure in academic, professional and leisure environments allowing the practice of techniques of blood flow restriction even safer, more efficient and accessible.
publishDate 2018
dc.date.issued.fl_str_mv 2018-07-12
dc.date.accessioned.fl_str_mv 2020-02-04T15:57:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SOARES, Fernanda Lima. Concordância entre doppler portátil e oxímetro de pulso na determinação da pressão arterial de oclusão de jovens saudáveis.. 2018. 86 folhas. Dissertação( Programa de Pós-Graduação em Educação Física) - Universidade Federal do Maranhão, São Luís, 2018.
dc.identifier.uri.fl_str_mv https://tedebc.ufma.br/jspui/handle/tede/tede/3036
identifier_str_mv SOARES, Fernanda Lima. Concordância entre doppler portátil e oxímetro de pulso na determinação da pressão arterial de oclusão de jovens saudáveis.. 2018. 86 folhas. Dissertação( Programa de Pós-Graduação em Educação Física) - Universidade Federal do Maranhão, São Luís, 2018.
url https://tedebc.ufma.br/jspui/handle/tede/tede/3036
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.publisher.program.fl_str_mv PROGRAMA DE PÓS-GRADUACAO EM EDUCAÇÃO FÍSICA
dc.publisher.initials.fl_str_mv UFMA
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv DEPARTAMENTO DE EDUCAÇÃO FÍSICA/CCBS
publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFMA
instname:Universidade Federal do Maranhão (UFMA)
instacron:UFMA
instname_str Universidade Federal do Maranhão (UFMA)
instacron_str UFMA
institution UFMA
reponame_str Biblioteca Digital de Teses e Dissertações da UFMA
collection Biblioteca Digital de Teses e Dissertações da UFMA
bitstream.url.fl_str_mv http://tedebc.ufma.br:8080/bitstream/tede/3036/2/Fernanda+Lima+Soares.pdf
http://tedebc.ufma.br:8080/bitstream/tede/3036/1/license.txt
bitstream.checksum.fl_str_mv e7087a50f3c2f7445b7fe49177b3bede
97eeade1fce43278e63fe063657f8083
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)
repository.mail.fl_str_mv repositorio@ufma.br||repositorio@ufma.br
_version_ 1809926195766099968