Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido

Detalhes bibliográficos
Autor(a) principal: DIAS, Luciana Cutrim
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFMA
Texto Completo: https://tedebc.ufma.br/jspui/handle/tede/tede/3908
Resumo: Pyrene is considered an emerging microcontaminant due to its persistent toxicity in living beings, being a compound capable of spreading rapidly through tissues, as well as crossing the blood-brain barrier leaving the central nervous system unprotected, allowing the passage of toxic substances found in the blood . Therefore, it is of great importance to control this contaminant in groundwater. The present work aimed to propose a procedure for the determination of pyrene in groundwater at a gas station using a voltammetric eletrodo based on reduced graphene oxide in Britton Robson (BR) 0.5 mol L -1 , pH 4.0 buffer solution. The proposed eletrodo showed an excellent electrochemical performance for the oxidation of pyrene under optimized experimental conditions. Through the standard deviations of the calibration curves, LD and LQ were calculated for the analyte, where the detection limit obtained was 5.6 x 10-08 and the quantification limit 1.8 x 10-07. The linearity range varied between 9.9x10-6 mol L-1 to 4.7x10-5 mol L-1 . The coefficients of variation (precision) of the electroanalytical measurements of the eletrodo were 7.01% (repeatability) and 1.57% (reproducibility). The application of the eletrodo to a real sample was carried out using the enrichment method. The developed eletrodo was successfully applied in the determination of pyrene in a groundwater sample, in which a recovery of 101.3% (accuracy) was obtained. And the modified electrode showed a good electroanalytical response in terms of sensitivity and stability. These results indicate that this procedure is sufficiently suitable as an alternative method to determine the content of pyrene in groundwater.
id UFMA_ff3160ddc3c349dbbc501a4b0f65107c
oai_identifier_str oai:tede2:tede/3908
network_acronym_str UFMA
network_name_str Biblioteca Digital de Teses e Dissertações da UFMA
repository_id_str 2131
spelling MARQUES, Edmar Pereirahttp://lattes.cnpq.br/2468528554511482MARQUES, Edmar Pereirahttp://lattes.cnpq.br/2468528554511482VARELA JUNIOR, Jaldyr de Jesus Gomeshttp://lattes.cnpq.br/5125904184711352MOUCHREK FILHO, Victor Eliashttp://lattes.cnpq.br/2381183158978639http://lattes.cnpq.br/5677108805593305DIAS, Luciana Cutrim2022-08-03T10:47:15Z2020-03-12DIAS, Luciana Cutrim. Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido. 2020. 71 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís, 2020.https://tedebc.ufma.br/jspui/handle/tede/tede/3908Pyrene is considered an emerging microcontaminant due to its persistent toxicity in living beings, being a compound capable of spreading rapidly through tissues, as well as crossing the blood-brain barrier leaving the central nervous system unprotected, allowing the passage of toxic substances found in the blood . Therefore, it is of great importance to control this contaminant in groundwater. The present work aimed to propose a procedure for the determination of pyrene in groundwater at a gas station using a voltammetric eletrodo based on reduced graphene oxide in Britton Robson (BR) 0.5 mol L -1 , pH 4.0 buffer solution. The proposed eletrodo showed an excellent electrochemical performance for the oxidation of pyrene under optimized experimental conditions. Through the standard deviations of the calibration curves, LD and LQ were calculated for the analyte, where the detection limit obtained was 5.6 x 10-08 and the quantification limit 1.8 x 10-07. The linearity range varied between 9.9x10-6 mol L-1 to 4.7x10-5 mol L-1 . The coefficients of variation (precision) of the electroanalytical measurements of the eletrodo were 7.01% (repeatability) and 1.57% (reproducibility). The application of the eletrodo to a real sample was carried out using the enrichment method. The developed eletrodo was successfully applied in the determination of pyrene in a groundwater sample, in which a recovery of 101.3% (accuracy) was obtained. And the modified electrode showed a good electroanalytical response in terms of sensitivity and stability. These results indicate that this procedure is sufficiently suitable as an alternative method to determine the content of pyrene in groundwater.O pireno é considerado um microcontaminante emergente devido à sua persistente toxicidade nos seres vivos, sendo um composto capaz de se difundir rapidamente pelos tecidos, bem como de cruzar a barreira hematoencefálica deixando o sistema nervoso central desprotegido, permitindo a passagem de substâncias tóxicas encontradas no sangue. Portanto, é de grande importância controlar esse contaminante nas águas subterrâneas. O presente trabalho teve como objetivo propor um procedimento para determinação do pireno em água subterrânea de posto de combustívei utilizando um eletrodo voltamétrico baseado em óxido de grafeno reduzido em solução tampão Britton Robson (BR) 0,5 mol L -1 , pH 4.0. O eletrodo proposto apresentou um excelente desempenho eletroquímico para a oxidação do pireno sob condições experimentais otimizadas. Através dos desvios padrão das curvas de calibração foram calculados o LD e LQ para o analito, onde o limite de detecção obtido foi de 5,6 x10-08 mol L-1 e o limite de quantificação 1,8 x10-07 mol L-1 . A faixa de linearidade variou entre 9,9x10-6 mol L-1 a 4,7x10-5 mol L-1 . Os coeficientes de variação (precisão) das medidas eletroanalíticas do eletrodo foram 7,01% (repetibilidade) e 1,57% (reprodutibilidade). A aplicação do eletrodo em amostra real, foi realizada pelo método do enriquecimento. O eletrodo desenvolvido foi aplicado com sucesso na determinação de pireno em amostra de água subterrânea, na qual obteve-se uma recuperação de 101,3% (exatidão). E o eletrodo modificado mostrou uma boa resposta eletroanalítica em termos de sensibilidade e estabilidade. Estes resultados indicam que este procedimento é suficientemente adequado como método alternativo para determinar o conteúdo de pireno em água subterrânea.Submitted by Jonathan Sousa de Almeida (jonathan.sousa@ufma.br) on 2022-08-03T10:47:15Z No. of bitstreams: 1 LUCIANACUTRIMDIAS.pdf: 1981550 bytes, checksum: 2fec116a3708285582bbdf6ba49e14e5 (MD5)Made available in DSpace on 2022-08-03T10:47:15Z (GMT). No. of bitstreams: 1 LUCIANACUTRIMDIAS.pdf: 1981550 bytes, checksum: 2fec116a3708285582bbdf6ba49e14e5 (MD5) Previous issue date: 2020-03-12CAPESapplication/pdfporUniversidade Federal do MaranhãoPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETUFMABrasilDEPARTAMENTO DE QUÍMICA/CCETHPA;Pireno;águas subterrâneas;posto de combustível;voltametria.HPA;Pyrene;groundwater;fuel station;voltammetry.Engenharia SanitáriaQuímicaProcedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzidoElectroanalytical procedure for the determination of pyrene in groundwater using reduced graphene oxide modified glassy carbon electrodeinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UFMAinstname:Universidade Federal do Maranhão (UFMA)instacron:UFMAORIGINALLUCIANACUTRIMDIAS.pdfLUCIANACUTRIMDIAS.pdfapplication/pdf1981550http://tedebc.ufma.br:8080/bitstream/tede/3908/2/LUCIANACUTRIMDIAS.pdf2fec116a3708285582bbdf6ba49e14e5MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82255http://tedebc.ufma.br:8080/bitstream/tede/3908/1/license.txt97eeade1fce43278e63fe063657f8083MD51tede/39082023-05-16 14:21:47.78oai:tede2:tede/3908IExJQ0VOw4dBIERFIERJU1RSSUJVScOHw4NPIE7Dg08tRVhDTFVTSVZBCgpDb20gYSBhcHJlc2VudGHDp8OjbyBkZXN0YSBsaWNlbsOnYSxvIGF1dG9yIChlcykgb3UgbyB0aXR1bGFyIGRvcyBkaXJlaXRvcyBkZSBhdXRvciBjb25jZWRlIMOgIFVuaXZlcnNpZGFkZSBGZWRlcmFsIGRvIE1hcmFuaMOjbyAoVUZNQSkgbyBkaXJlaXRvIG7Do28tZXhjbHVzaXZvIGRlIHJlcHJvZHV6aXIsIHRyYWR1emlyIChjb25mb3JtZSBkZWZpbmlkbyBhYmFpeG8pLCBlL291IGRpc3RyaWJ1aXIgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YcOnw6NvIChpbmNsdWluZG8gbyByZXN1bW8pIHBvciB0b2RvIG8gbXVuZG8gbm8gZm9ybWF0byBpbXByZXNzbyBlIGVsZXRyw7RuaWNvIGUgZW0gcXVhbHF1ZXIgbWVpbywgaW5jbHVpbmRvIG9zIGZvcm1hdG9zIMOhdWRpbyBvdSB2w61kZW8uCgpWb2PDqiBjb25jb3JkYSBxdWUgYSBVRk1BIHBvZGUsIHNlbSBhbHRlcmFyIG8gY29udGXDumRvLCB0cmFuc3BvciBhIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gcGFyYSBxdWFscXVlciBtZWlvIG91IGZvcm1hdG8gcGFyYSBmaW5zIGRlIHByZXNlcnZhw6fDo28uCgpWb2PDqiB0YW1iw6ltIGNvbmNvcmRhIHF1ZSBhIFVGTUEgcG9kZSBtYW50ZXIgbWFpcyBkZSB1bWEgY8OzcGlhIGRlIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gcGFyYSBmaW5zIGRlIHNlZ3VyYW7Dp2EsIGJhY2stdXAgZSBwcmVzZXJ2YcOnw6NvLgoKVm9jw6ogZGVjbGFyYSBxdWUgYSBzdWEgdGVzZSBvdSBkaXNzZXJ0YcOnw6NvIMOpIG9yaWdpbmFsIGUgcXVlIHZvY8OqIHRlbSBvIHBvZGVyIGRlIGNvbmNlZGVyIG9zIGRpcmVpdG9zIGNvbnRpZG9zIG5lc3RhIGxpY2Vuw6dhLiBWb2PDqiB0YW1iw6ltIGRlY2xhcmEgcXVlIG8gZGVww7NzaXRvIGRhIHN1YSB0ZXNlIG91IGRpc3NlcnRhw6fDo28gbsOjbywgcXVlIHNlamEgZGUgc2V1IGNvbmhlY2ltZW50bywgaW5mcmluZ2UgZGlyZWl0b3MgYXV0b3JhaXMgZGUgbmluZ3XDqW0uCgpDYXNvIGEgc3VhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbyBjb250ZW5oYSBtYXRlcmlhbCBxdWUgdm9jw6ogbsOjbyBwb3NzdWkgYSB0aXR1bGFyaWRhZGUgZG9zIGRpcmVpdG9zIGF1dG9yYWlzLCB2b2PDqiBkZWNsYXJhIHF1ZSBvYnRldmUgYSBwZXJtaXNzw6NvIGlycmVzdHJpdGEgZG8gZGV0ZW50b3IgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIHBhcmEgY29uY2VkZXIgw6AgVUZNQSBvcyBkaXJlaXRvcyBhcHJlc2VudGFkb3MgbmVzdGEgbGljZW7Dp2EsIGUgcXVlIGVzc2UgbWF0ZXJpYWwgZGUgcHJvcHJpZWRhZGUgZGUgdGVyY2Vpcm9zIGVzdMOhIGNsYXJhbWVudGUgaWRlbnRpZmljYWRvIGUgcmVjb25oZWNpZG8gbm8gdGV4dG8gb3Ugbm8gY29udGXDumRvIGRhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbyBvcmEgZGVwb3NpdGFkYS4KCkNBU08gQSBURVNFIE9VIERJU1NFUlRBw4fDg08gT1JBIERFUE9TSVRBREEgVEVOSEEgU0lETyBSRVNVTFRBRE8gREUgVU0gUEFUUk9Dw41OSU8gT1UgQVBPSU8gREUgVU1BIEFHw4pOQ0lBIERFIEZPTUVOVE8gT1UgT1VUUk8gT1JHQU5JU01PIFFVRSBOw4NPIFNFSkEgQSBVRk1BLCBWT0PDiiBERUNMQVJBIFFVRSBSRVNQRUlUT1UgVE9ET1MgRSBRVUFJU1FVRVIgRElSRUlUT1MgREUgUkVWSVPDg08gQ09NTyBUQU1Cw4lNIEFTIERFTUFJUyBPQlJJR0HDh8OVRVMgRVhJR0lEQVMgUE9SIENPTlRSQVRPIE9VIEFDT1JETy4KCkEgVUZNQSBzZSBjb21wcm9tZXRlIGEgaWRlbnRpZmljYXIgY2xhcmFtZW50ZSBvIHNldSBub21lIG91IG8ocykgbm9tZShzKSBkbyhzKSBkZXRlbnRvcihlcykgZG9zIGRpcmVpdG9zIGF1dG9yYWlzIGRhIHRlc2Ugb3UgZGlzc2VydGHDp8OjbywgZSBuw6NvIGZhcsOhIHF1YWxxdWVyIGFsdGVyYcOnw6NvLCBhbMOpbSBkYXF1ZWxhcyBjb25jZWRpZGFzIHBvciBlc3RhIGxpY2Vuw6dhLgoKRGVjbGFyYSB0YW1iw6ltIHF1ZSB0b2RhcyBhcyBhZmlsaWHDp8O1ZXMgY29ycG9yYXRpdmFzIG91IGluc3RpdHVjaW9uYWlzIGUgdG9kYXMgYXMgZm9udGVzIGRlIGFwb2lvIGZpbmFuY2Vpcm8gYW8gdHJhYmFsaG8gZXN0w6NvIGRldmlkYW1lbnRlIGNpdGFkYXMgb3UgbWVuY2lvbmFkYXMgZSBjZXJ0aWZpY2EgcXVlIG7Do28gaMOhIG5lbmh1bSBpbnRlcmVzc2UgY29tZXJjaWFsIG91IGFzc29jaWF0aXZvIHF1ZSByZXByZXNlbnRlIGNvbmZsaXRvIGRlIGludGVyZXNzZSBlbSBjb25leMOjbyBjb20gbyB0cmFiYWxobyBzdWJtZXRpZG8uCgoKCgoKCgo=Biblioteca Digital de Teses e Dissertaçõeshttps://tedebc.ufma.br/jspui/PUBhttp://tedebc.ufma.br:8080/oai/requestrepositorio@ufma.br||repositorio@ufma.bropendoar:21312023-05-16T17:21:47Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)false
dc.title.por.fl_str_mv Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
dc.title.alternative.eng.fl_str_mv Electroanalytical procedure for the determination of pyrene in groundwater using reduced graphene oxide modified glassy carbon electrode
title Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
spellingShingle Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
DIAS, Luciana Cutrim
HPA;
Pireno;
águas subterrâneas;
posto de combustível;
voltametria.
HPA;
Pyrene;
groundwater;
fuel station;
voltammetry.
Engenharia Sanitária
Química
title_short Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
title_full Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
title_fullStr Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
title_full_unstemmed Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
title_sort Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido
author DIAS, Luciana Cutrim
author_facet DIAS, Luciana Cutrim
author_role author
dc.contributor.advisor1.fl_str_mv MARQUES, Edmar Pereira
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/2468528554511482
dc.contributor.referee1.fl_str_mv MARQUES, Edmar Pereira
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/2468528554511482
dc.contributor.referee2.fl_str_mv VARELA JUNIOR, Jaldyr de Jesus Gomes
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/5125904184711352
dc.contributor.referee3.fl_str_mv MOUCHREK FILHO, Victor Elias
dc.contributor.referee3Lattes.fl_str_mv http://lattes.cnpq.br/2381183158978639
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/5677108805593305
dc.contributor.author.fl_str_mv DIAS, Luciana Cutrim
contributor_str_mv MARQUES, Edmar Pereira
MARQUES, Edmar Pereira
VARELA JUNIOR, Jaldyr de Jesus Gomes
MOUCHREK FILHO, Victor Elias
dc.subject.por.fl_str_mv HPA;
Pireno;
águas subterrâneas;
posto de combustível;
voltametria.
topic HPA;
Pireno;
águas subterrâneas;
posto de combustível;
voltametria.
HPA;
Pyrene;
groundwater;
fuel station;
voltammetry.
Engenharia Sanitária
Química
dc.subject.eng.fl_str_mv HPA;
Pyrene;
groundwater;
fuel station;
voltammetry.
dc.subject.cnpq.fl_str_mv Engenharia Sanitária
Química
description Pyrene is considered an emerging microcontaminant due to its persistent toxicity in living beings, being a compound capable of spreading rapidly through tissues, as well as crossing the blood-brain barrier leaving the central nervous system unprotected, allowing the passage of toxic substances found in the blood . Therefore, it is of great importance to control this contaminant in groundwater. The present work aimed to propose a procedure for the determination of pyrene in groundwater at a gas station using a voltammetric eletrodo based on reduced graphene oxide in Britton Robson (BR) 0.5 mol L -1 , pH 4.0 buffer solution. The proposed eletrodo showed an excellent electrochemical performance for the oxidation of pyrene under optimized experimental conditions. Through the standard deviations of the calibration curves, LD and LQ were calculated for the analyte, where the detection limit obtained was 5.6 x 10-08 and the quantification limit 1.8 x 10-07. The linearity range varied between 9.9x10-6 mol L-1 to 4.7x10-5 mol L-1 . The coefficients of variation (precision) of the electroanalytical measurements of the eletrodo were 7.01% (repeatability) and 1.57% (reproducibility). The application of the eletrodo to a real sample was carried out using the enrichment method. The developed eletrodo was successfully applied in the determination of pyrene in a groundwater sample, in which a recovery of 101.3% (accuracy) was obtained. And the modified electrode showed a good electroanalytical response in terms of sensitivity and stability. These results indicate that this procedure is sufficiently suitable as an alternative method to determine the content of pyrene in groundwater.
publishDate 2020
dc.date.issued.fl_str_mv 2020-03-12
dc.date.accessioned.fl_str_mv 2022-08-03T10:47:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv DIAS, Luciana Cutrim. Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido. 2020. 71 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís, 2020.
dc.identifier.uri.fl_str_mv https://tedebc.ufma.br/jspui/handle/tede/tede/3908
identifier_str_mv DIAS, Luciana Cutrim. Procedimento eletroanalitico para determinação de pireno em água subterrânea usando eletrodo de carbono vitreo modificado com oxido de grafeno reduzido. 2020. 71 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luís, 2020.
url https://tedebc.ufma.br/jspui/handle/tede/tede/3908
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.publisher.program.fl_str_mv PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET
dc.publisher.initials.fl_str_mv UFMA
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv DEPARTAMENTO DE QUÍMICA/CCET
publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFMA
instname:Universidade Federal do Maranhão (UFMA)
instacron:UFMA
instname_str Universidade Federal do Maranhão (UFMA)
instacron_str UFMA
institution UFMA
reponame_str Biblioteca Digital de Teses e Dissertações da UFMA
collection Biblioteca Digital de Teses e Dissertações da UFMA
bitstream.url.fl_str_mv http://tedebc.ufma.br:8080/bitstream/tede/3908/2/LUCIANACUTRIMDIAS.pdf
http://tedebc.ufma.br:8080/bitstream/tede/3908/1/license.txt
bitstream.checksum.fl_str_mv 2fec116a3708285582bbdf6ba49e14e5
97eeade1fce43278e63fe063657f8083
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)
repository.mail.fl_str_mv repositorio@ufma.br||repositorio@ufma.br
_version_ 1809926204790145024