Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352014000501351 |
Resumo: | In the initial stage of traumatic brain injury, the use of 1.0 inspired oxygen fraction (FiO2) is indicated. However, high FiO2 has been correlated with atelectasis. Thus, the effects of FiO2= 1.0 and FiO2= 0.6 on the cardiopulmonary function in propofol-anesthetized dogs with high intracranial pressure (ICP) were evaluated. Eight dogs were anesthetized on two occasions, receiving, during controlled ventilation, an FiO2= 1 (G100) or an FiO2= 0.6 (G60). Propofol was used for induction (10mg.kg-1) followed by a continuous rate infusion (0.6mg.kg-1.minute-1). An increase in the ICP was induced by temporary obliteration of the right jugular vein (OJv) 50 minutes after induction of anesthesia. The measurement was taken twenty minutes after OJv (T0) and then at 15-minute intervals (T15 to T60). Alveolar oxygen partial pressure in G60 was lower than in G100 during the whole procedure. Alveolar-arterial oxygen gradient in G100 was greater than in G60 at T0 and at T60. No differences were observed for arterial oxygen partial pressure/inspired oxygen fraction ratio, arterial-to-alveolar oxygen pressure ratio, respiratory index, venous admixture, oxygen delivery, oxygen consumption, oxygen extraction, heart rate, mean pulmonary arterial pressure, pulmonary arterial occlusion pressure, cardiac index, stroke index and systemic vascular resistance index. In G100, mean arterial pressure at T0 was higher than at T45. In dogs with high ICP, the cardiopulmonary function was not influenced by the different FiO2 used. |
id |
UFMG-8_2654b0675675baabb6dceee3918ee24b |
---|---|
oai_identifier_str |
oai:scielo:S0102-09352014000501351 |
network_acronym_str |
UFMG-8 |
network_name_str |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
repository_id_str |
|
spelling |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary functiondogtotal intravenous anesthesiacerebral autoregulationhemodynamicvenous admixtureIn the initial stage of traumatic brain injury, the use of 1.0 inspired oxygen fraction (FiO2) is indicated. However, high FiO2 has been correlated with atelectasis. Thus, the effects of FiO2= 1.0 and FiO2= 0.6 on the cardiopulmonary function in propofol-anesthetized dogs with high intracranial pressure (ICP) were evaluated. Eight dogs were anesthetized on two occasions, receiving, during controlled ventilation, an FiO2= 1 (G100) or an FiO2= 0.6 (G60). Propofol was used for induction (10mg.kg-1) followed by a continuous rate infusion (0.6mg.kg-1.minute-1). An increase in the ICP was induced by temporary obliteration of the right jugular vein (OJv) 50 minutes after induction of anesthesia. The measurement was taken twenty minutes after OJv (T0) and then at 15-minute intervals (T15 to T60). Alveolar oxygen partial pressure in G60 was lower than in G100 during the whole procedure. Alveolar-arterial oxygen gradient in G100 was greater than in G60 at T0 and at T60. No differences were observed for arterial oxygen partial pressure/inspired oxygen fraction ratio, arterial-to-alveolar oxygen pressure ratio, respiratory index, venous admixture, oxygen delivery, oxygen consumption, oxygen extraction, heart rate, mean pulmonary arterial pressure, pulmonary arterial occlusion pressure, cardiac index, stroke index and systemic vascular resistance index. In G100, mean arterial pressure at T0 was higher than at T45. In dogs with high ICP, the cardiopulmonary function was not influenced by the different FiO2 used.Universidade Federal de Minas Gerais, Escola de Veterinária2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352014000501351Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.66 n.5 2014reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/1678-6519info:eu-repo/semantics/openAccessLopes,P.C. FerroNunes,N.Belmonte,E.AAlmeida,R. M.Dias,L.G.G.G.Pereira Neto,G.B.Souza,A.L.G.eng2015-10-14T00:00:00Zoai:scielo:S0102-09352014000501351Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2015-10-14T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false |
dc.title.none.fl_str_mv |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
title |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
spellingShingle |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function Lopes,P.C. Ferro dog total intravenous anesthesia cerebral autoregulation hemodynamic venous admixture |
title_short |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
title_full |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
title_fullStr |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
title_full_unstemmed |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
title_sort |
Two levels of the inspired oxygen fraction in propofol-anesthetized dogs with high intracranial pressure: cardiopulmonary function |
author |
Lopes,P.C. Ferro |
author_facet |
Lopes,P.C. Ferro Nunes,N. Belmonte,E.A Almeida,R. M. Dias,L.G.G.G. Pereira Neto,G.B. Souza,A.L.G. |
author_role |
author |
author2 |
Nunes,N. Belmonte,E.A Almeida,R. M. Dias,L.G.G.G. Pereira Neto,G.B. Souza,A.L.G. |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Lopes,P.C. Ferro Nunes,N. Belmonte,E.A Almeida,R. M. Dias,L.G.G.G. Pereira Neto,G.B. Souza,A.L.G. |
dc.subject.por.fl_str_mv |
dog total intravenous anesthesia cerebral autoregulation hemodynamic venous admixture |
topic |
dog total intravenous anesthesia cerebral autoregulation hemodynamic venous admixture |
description |
In the initial stage of traumatic brain injury, the use of 1.0 inspired oxygen fraction (FiO2) is indicated. However, high FiO2 has been correlated with atelectasis. Thus, the effects of FiO2= 1.0 and FiO2= 0.6 on the cardiopulmonary function in propofol-anesthetized dogs with high intracranial pressure (ICP) were evaluated. Eight dogs were anesthetized on two occasions, receiving, during controlled ventilation, an FiO2= 1 (G100) or an FiO2= 0.6 (G60). Propofol was used for induction (10mg.kg-1) followed by a continuous rate infusion (0.6mg.kg-1.minute-1). An increase in the ICP was induced by temporary obliteration of the right jugular vein (OJv) 50 minutes after induction of anesthesia. The measurement was taken twenty minutes after OJv (T0) and then at 15-minute intervals (T15 to T60). Alveolar oxygen partial pressure in G60 was lower than in G100 during the whole procedure. Alveolar-arterial oxygen gradient in G100 was greater than in G60 at T0 and at T60. No differences were observed for arterial oxygen partial pressure/inspired oxygen fraction ratio, arterial-to-alveolar oxygen pressure ratio, respiratory index, venous admixture, oxygen delivery, oxygen consumption, oxygen extraction, heart rate, mean pulmonary arterial pressure, pulmonary arterial occlusion pressure, cardiac index, stroke index and systemic vascular resistance index. In G100, mean arterial pressure at T0 was higher than at T45. In dogs with high ICP, the cardiopulmonary function was not influenced by the different FiO2 used. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352014000501351 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352014000501351 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1678-6519 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais, Escola de Veterinária |
publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais, Escola de Veterinária |
dc.source.none.fl_str_mv |
Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.66 n.5 2014 reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online) instname:Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
instname_str |
Universidade Federal de Minas Gerais (UFMG) |
instacron_str |
UFMG |
institution |
UFMG |
reponame_str |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
collection |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
repository.name.fl_str_mv |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG) |
repository.mail.fl_str_mv |
journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br |
_version_ |
1750220888078286848 |