Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk

Detalhes bibliográficos
Autor(a) principal: Oliveira,M.C.P.P.
Data de Publicação: 2012
Outros Autores: Silva,N.M.A., Bastos,L.P.F., Fonseca,L.M., Cerqueira,M.M.O.P., Leite,M.O., Conrrado,R.S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivo brasileiro de medicina veterinária e zootecnia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352012000500037
Resumo: The objective of this study was to evaluate the CombiScope FTIR equipment based on Fourier Transform Infrared methodology (FTIR), to assess the content of milk urea nitrogen (MUN) in Brazil. Repeatability and reproducibility of CombiScopeTM FTIR (Delta Instruments), and comparison with an enzymatic automated method (Chemspec® 150; Bentley Instruments) were tested to measure raw milk urea nitrogen (MUN). Additionally, MUN levels stability after storage of raw milk samples at 4ºC, and 20ºC for up to 15 days, and capability and precision to detect extraneous urea added as an adulterant to the milk were evaluated by FTIR equipment. There was a high correlation coefficient for the analysis of MUN by FTIR equipment, when compared with the automated enzymatic method, with no significant difference between both. MUN concentration in raw milk remained stable at temperatures of 4ºC for up to 15 days of storage, but after 3 days of storage at 20ºC there was an increase in the MUN levels. The CombiScope FTIR equipment proved to be a reliable method for analysis of MUN content in raw milk. However, results for MUN were not linear with the amount of extraneous urea added to raw milk, having a significant difference for samples when 40mg/dL of urea was added to milk.
id UFMG-8_7a2da8a7d289f394f4b3d084d507d375
oai_identifier_str oai:scielo:S0102-09352012000500037
network_acronym_str UFMG-8
network_name_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository_id_str
spelling Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milkmilkvalidationmilk urea nitrogeninfrared spectroscopyFTIRThe objective of this study was to evaluate the CombiScope FTIR equipment based on Fourier Transform Infrared methodology (FTIR), to assess the content of milk urea nitrogen (MUN) in Brazil. Repeatability and reproducibility of CombiScopeTM FTIR (Delta Instruments), and comparison with an enzymatic automated method (Chemspec® 150; Bentley Instruments) were tested to measure raw milk urea nitrogen (MUN). Additionally, MUN levels stability after storage of raw milk samples at 4ºC, and 20ºC for up to 15 days, and capability and precision to detect extraneous urea added as an adulterant to the milk were evaluated by FTIR equipment. There was a high correlation coefficient for the analysis of MUN by FTIR equipment, when compared with the automated enzymatic method, with no significant difference between both. MUN concentration in raw milk remained stable at temperatures of 4ºC for up to 15 days of storage, but after 3 days of storage at 20ºC there was an increase in the MUN levels. The CombiScope FTIR equipment proved to be a reliable method for analysis of MUN content in raw milk. However, results for MUN were not linear with the amount of extraneous urea added to raw milk, having a significant difference for samples when 40mg/dL of urea was added to milk.Universidade Federal de Minas Gerais, Escola de Veterinária2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352012000500037Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.64 n.5 2012reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/S0102-09352012000500037info:eu-repo/semantics/openAccessOliveira,M.C.P.P.Silva,N.M.A.Bastos,L.P.F.Fonseca,L.M.Cerqueira,M.M.O.P.Leite,M.O.Conrrado,R.S.eng2012-11-12T00:00:00Zoai:scielo:S0102-09352012000500037Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2012-11-12T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
title Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
spellingShingle Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
Oliveira,M.C.P.P.
milk
validation
milk urea nitrogen
infrared spectroscopy
FTIR
title_short Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
title_full Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
title_fullStr Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
title_full_unstemmed Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
title_sort Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk
author Oliveira,M.C.P.P.
author_facet Oliveira,M.C.P.P.
Silva,N.M.A.
Bastos,L.P.F.
Fonseca,L.M.
Cerqueira,M.M.O.P.
Leite,M.O.
Conrrado,R.S.
author_role author
author2 Silva,N.M.A.
Bastos,L.P.F.
Fonseca,L.M.
Cerqueira,M.M.O.P.
Leite,M.O.
Conrrado,R.S.
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Oliveira,M.C.P.P.
Silva,N.M.A.
Bastos,L.P.F.
Fonseca,L.M.
Cerqueira,M.M.O.P.
Leite,M.O.
Conrrado,R.S.
dc.subject.por.fl_str_mv milk
validation
milk urea nitrogen
infrared spectroscopy
FTIR
topic milk
validation
milk urea nitrogen
infrared spectroscopy
FTIR
description The objective of this study was to evaluate the CombiScope FTIR equipment based on Fourier Transform Infrared methodology (FTIR), to assess the content of milk urea nitrogen (MUN) in Brazil. Repeatability and reproducibility of CombiScopeTM FTIR (Delta Instruments), and comparison with an enzymatic automated method (Chemspec® 150; Bentley Instruments) were tested to measure raw milk urea nitrogen (MUN). Additionally, MUN levels stability after storage of raw milk samples at 4ºC, and 20ºC for up to 15 days, and capability and precision to detect extraneous urea added as an adulterant to the milk were evaluated by FTIR equipment. There was a high correlation coefficient for the analysis of MUN by FTIR equipment, when compared with the automated enzymatic method, with no significant difference between both. MUN concentration in raw milk remained stable at temperatures of 4ºC for up to 15 days of storage, but after 3 days of storage at 20ºC there was an increase in the MUN levels. The CombiScope FTIR equipment proved to be a reliable method for analysis of MUN content in raw milk. However, results for MUN were not linear with the amount of extraneous urea added to raw milk, having a significant difference for samples when 40mg/dL of urea was added to milk.
publishDate 2012
dc.date.none.fl_str_mv 2012-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352012000500037
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352012000500037
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-09352012000500037
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
dc.source.none.fl_str_mv Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.64 n.5 2012
reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
collection Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository.name.fl_str_mv Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br
_version_ 1750220885840625664