Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601873 |
Resumo: | ABSTRACT Hydroxyapatite (HA) is widely used as a biomaterial for bone repair and metallic prostheses coating. The main limitations of the current commercial synthetic hydroxyapatite compounds include high cost and decreased availability, especially for veterinary medicine purposes. Additionally, it is thought that HA biocompatibility and bioactivity could be enhanced by the addition of metal compounds. The objective of this work was to compare the subcutaneous tissue response of commercial and engineered hydroxyapatite obtained from the bovine femur diaphysis mixed with different concentrations of hexa-hydrated Zinc Nitrate in rabbits. Twenty-Five New Zealand female rabbits were used. Five treatments were done according to HA composition (commercial HA, no Zn-HA, 0.1M Zn, 0.2M Zn, and 0.3M Zn). Each treatment was evaluated at five time-points (8, 15, 30, 60 and 90 days post-implantation). Histopathologic analysis was performed to assess inflammation by polymorphonuclear cells infiltration, neovascularization, and fibrosis. Results obtained in this work suggest that general inflammation decreased after 60 days of implantation regardless of Zn concentration. Fibrosis score was increased in the commercial HP compared to control and Zn-hydrated HA. This paper shows that bovine hydroxyapatite is a biocompatible material regardless of nitrate Zinc concentration and has the same properties of commercial hydroxyapatite. |
id |
UFMG-8_e2afe8f3a4d7da448dcb4876fdddf4b7 |
---|---|
oai_identifier_str |
oai:scielo:S0102-09352019000601873 |
network_acronym_str |
UFMG-8 |
network_name_str |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
repository_id_str |
|
spelling |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbitsanimal modelbiocompatibilityboneintegrationABSTRACT Hydroxyapatite (HA) is widely used as a biomaterial for bone repair and metallic prostheses coating. The main limitations of the current commercial synthetic hydroxyapatite compounds include high cost and decreased availability, especially for veterinary medicine purposes. Additionally, it is thought that HA biocompatibility and bioactivity could be enhanced by the addition of metal compounds. The objective of this work was to compare the subcutaneous tissue response of commercial and engineered hydroxyapatite obtained from the bovine femur diaphysis mixed with different concentrations of hexa-hydrated Zinc Nitrate in rabbits. Twenty-Five New Zealand female rabbits were used. Five treatments were done according to HA composition (commercial HA, no Zn-HA, 0.1M Zn, 0.2M Zn, and 0.3M Zn). Each treatment was evaluated at five time-points (8, 15, 30, 60 and 90 days post-implantation). Histopathologic analysis was performed to assess inflammation by polymorphonuclear cells infiltration, neovascularization, and fibrosis. Results obtained in this work suggest that general inflammation decreased after 60 days of implantation regardless of Zn concentration. Fibrosis score was increased in the commercial HP compared to control and Zn-hydrated HA. This paper shows that bovine hydroxyapatite is a biocompatible material regardless of nitrate Zinc concentration and has the same properties of commercial hydroxyapatite.Universidade Federal de Minas Gerais, Escola de Veterinária2019-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601873Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.71 n.6 2019reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/1678-4162-11407info:eu-repo/semantics/openAccessMuñoz,L.C.Cardona.-Ramirez,S.Silva,R.F.eng2019-12-10T00:00:00Zoai:scielo:S0102-09352019000601873Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2019-12-10T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false |
dc.title.none.fl_str_mv |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
title |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
spellingShingle |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits Muñoz,L.C. animal model biocompatibility bone integration |
title_short |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
title_full |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
title_fullStr |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
title_full_unstemmed |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
title_sort |
Comparison of subcutaneous inflammatory response to commercial and engineered zinc hydroxyapatite implants in rabbits |
author |
Muñoz,L.C. |
author_facet |
Muñoz,L.C. Cardona.-Ramirez,S. Silva,R.F. |
author_role |
author |
author2 |
Cardona.-Ramirez,S. Silva,R.F. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Muñoz,L.C. Cardona.-Ramirez,S. Silva,R.F. |
dc.subject.por.fl_str_mv |
animal model biocompatibility bone integration |
topic |
animal model biocompatibility bone integration |
description |
ABSTRACT Hydroxyapatite (HA) is widely used as a biomaterial for bone repair and metallic prostheses coating. The main limitations of the current commercial synthetic hydroxyapatite compounds include high cost and decreased availability, especially for veterinary medicine purposes. Additionally, it is thought that HA biocompatibility and bioactivity could be enhanced by the addition of metal compounds. The objective of this work was to compare the subcutaneous tissue response of commercial and engineered hydroxyapatite obtained from the bovine femur diaphysis mixed with different concentrations of hexa-hydrated Zinc Nitrate in rabbits. Twenty-Five New Zealand female rabbits were used. Five treatments were done according to HA composition (commercial HA, no Zn-HA, 0.1M Zn, 0.2M Zn, and 0.3M Zn). Each treatment was evaluated at five time-points (8, 15, 30, 60 and 90 days post-implantation). Histopathologic analysis was performed to assess inflammation by polymorphonuclear cells infiltration, neovascularization, and fibrosis. Results obtained in this work suggest that general inflammation decreased after 60 days of implantation regardless of Zn concentration. Fibrosis score was increased in the commercial HP compared to control and Zn-hydrated HA. This paper shows that bovine hydroxyapatite is a biocompatible material regardless of nitrate Zinc concentration and has the same properties of commercial hydroxyapatite. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601873 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352019000601873 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1678-4162-11407 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais, Escola de Veterinária |
publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais, Escola de Veterinária |
dc.source.none.fl_str_mv |
Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.71 n.6 2019 reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online) instname:Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
instname_str |
Universidade Federal de Minas Gerais (UFMG) |
instacron_str |
UFMG |
institution |
UFMG |
reponame_str |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
collection |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) |
repository.name.fl_str_mv |
Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG) |
repository.mail.fl_str_mv |
journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br |
_version_ |
1750220893694459904 |