Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFMG |
Texto Completo: | http://hdl.handle.net/1843/31029 |
Resumo: | Less than 50% of domestic sewage generated in Brazil are treated before their disposal in the environment, causing environmental hazard in the long term. The low rate of wastewater treatment can be explained by the high costs involved in the construction and operation of treatment plants, which are often carried out without proper planning, making sewage treatment economically unfeasible for municipalities and utilities. In this sense, 44 WWTPs from the Southeast region of Brazil were analyzed, aided by statistical tests, and compared. The treatment processes and the population equivalent of the station were analyzed, in order to supply data for future feasibility studies. The operational costs were analyzed, also, by the idleness of the stations and by the seasonality of flows. It was verified that costs per cubic meter of treated sewage presented a large variation from one WWTP to another, with great influence of the flow treated in the operational costs, and the Lagoons group had the lowest median of operational costs (median R$ 0.40/m³). The overall median of operational costs for all stations was R$ 0.96/m³, and the highest operating cost was R$ 4.67/m³, for WWTP 04, with a population equivalent of less than 5,000 inhabitants and whose treatment is performed by UASB reactor. The lowest operating cost was R$ 0.13/m³, for the WWTP 43, with a population equivalent of over 50,000 inhabitants and a treatment process by UASB reactors followed by trickling filters. |
id |
UFMG_a9dd63d3d85132b73eaf38a50e3c0e82 |
---|---|
oai_identifier_str |
oai:repositorio.ufmg.br:1843/31029 |
network_acronym_str |
UFMG |
network_name_str |
Repositório Institucional da UFMG |
repository_id_str |
|
spelling |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil.Estação de tratamento de esgotoCustos operacionaisEngenharia sanitáriaSaneamentoBrasil, SudesteEstação de Tratamento de Esgoto (ETE)Less than 50% of domestic sewage generated in Brazil are treated before their disposal in the environment, causing environmental hazard in the long term. The low rate of wastewater treatment can be explained by the high costs involved in the construction and operation of treatment plants, which are often carried out without proper planning, making sewage treatment economically unfeasible for municipalities and utilities. In this sense, 44 WWTPs from the Southeast region of Brazil were analyzed, aided by statistical tests, and compared. The treatment processes and the population equivalent of the station were analyzed, in order to supply data for future feasibility studies. The operational costs were analyzed, also, by the idleness of the stations and by the seasonality of flows. It was verified that costs per cubic meter of treated sewage presented a large variation from one WWTP to another, with great influence of the flow treated in the operational costs, and the Lagoons group had the lowest median of operational costs (median R$ 0.40/m³). The overall median of operational costs for all stations was R$ 0.96/m³, and the highest operating cost was R$ 4.67/m³, for WWTP 04, with a population equivalent of less than 5,000 inhabitants and whose treatment is performed by UASB reactor. The lowest operating cost was R$ 0.13/m³, for the WWTP 43, with a population equivalent of over 50,000 inhabitants and a treatment process by UASB reactors followed by trickling filters.Mais de 50% dos efluentes domésticos gerados no Brasil não são tratados antes da sua disposição no meio ambiente, causando, a longo prazo, prejuízos ambientais agravantes. Uma das possíveis causas do baixo índice de tratamento de efluentes pode ser o alto custo envolvido na construção e operação de estações de tratamento, que podem ser executadas sem o devido planejamento, tornando o tratamento adequado do esgoto economicamente inviável para as prefeituras e concessionárias. Nesse sentido, foram analisados comparativamente, e por meio de testes estatísticos, dados operacionais de 44 ETEs da região sudeste do Brasil quanto aos processos de tratamento e equivalente populacional da estação, visando subsidiar estudos de viabilidade futuros. Os custos operacionais foram analisados, também, levando em consideração a ociosidade das estações e a sazonalidade de vazões. Os resultados indicaram que os custos por metro cúbico de esgoto tratado apresentaram grande variação de uma ETE para outra, com grande influência da vazão tratada nos custos operacionais,. Avaliando-se todos os processos e portes, o processo de Lagoas apresentou a menor mediana de custos operacionais, com valor igual a R$ 0,40/m3. A mediana geral dos custos operacionais de todas as estações foi de R$ 0,96/m³, e o maior custo operacional foi de R$ 4,67/m³, para a ETE 04, com equivalente populacional menor do que 5.000 habitantes e cujo tratamento é realizado por reator UASB. Já o menor custo operacional foi de R$ 0,13/m³, para a ETE 43, com equivalente populacional maior do que 50.000 habitantes e processo de tratamento por reatores UASB seguidos de filtros biológicos percoladores.CNPq - Conselho Nacional de Desenvolvimento Científico e TecnológicoFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas GeraisCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível SuperiorINCT – Instituto nacional de ciência e tecnologia (Antigo Instituto do Milênio)Universidade Federal de Minas GeraisBrasilENG - DEPARTAMENTO DE ENGENHARIA SANITÁRIA E AMBIENTALPrograma de Pós-Graduação em Saneamento, Meio Ambiente e Recursos HídricosUFMGCésar Rossas Mota Filhohttp://lattes.cnpq.br/1851361200400216Marcos von SperlingCarlos Augusto de Lemos ChernicharoJackson de Oliveira PereiraFilipe Nepomuceno Bicalho Santos2019-11-18T17:06:34Z2019-11-18T17:06:34Z2018-07-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/1843/31029porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2019-11-19T06:30:23Zoai:repositorio.ufmg.br:1843/31029Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2019-11-19T06:30:23Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false |
dc.title.none.fl_str_mv |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
title |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
spellingShingle |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. Filipe Nepomuceno Bicalho Santos Estação de tratamento de esgoto Custos operacionais Engenharia sanitária Saneamento Brasil, Sudeste Estação de Tratamento de Esgoto (ETE) |
title_short |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
title_full |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
title_fullStr |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
title_full_unstemmed |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
title_sort |
Análise comparativa dos custos operacionais de 44 estações de tratamento de esgoto na região sudeste do Brasil. |
author |
Filipe Nepomuceno Bicalho Santos |
author_facet |
Filipe Nepomuceno Bicalho Santos |
author_role |
author |
dc.contributor.none.fl_str_mv |
César Rossas Mota Filho http://lattes.cnpq.br/1851361200400216 Marcos von Sperling Carlos Augusto de Lemos Chernicharo Jackson de Oliveira Pereira |
dc.contributor.author.fl_str_mv |
Filipe Nepomuceno Bicalho Santos |
dc.subject.por.fl_str_mv |
Estação de tratamento de esgoto Custos operacionais Engenharia sanitária Saneamento Brasil, Sudeste Estação de Tratamento de Esgoto (ETE) |
topic |
Estação de tratamento de esgoto Custos operacionais Engenharia sanitária Saneamento Brasil, Sudeste Estação de Tratamento de Esgoto (ETE) |
description |
Less than 50% of domestic sewage generated in Brazil are treated before their disposal in the environment, causing environmental hazard in the long term. The low rate of wastewater treatment can be explained by the high costs involved in the construction and operation of treatment plants, which are often carried out without proper planning, making sewage treatment economically unfeasible for municipalities and utilities. In this sense, 44 WWTPs from the Southeast region of Brazil were analyzed, aided by statistical tests, and compared. The treatment processes and the population equivalent of the station were analyzed, in order to supply data for future feasibility studies. The operational costs were analyzed, also, by the idleness of the stations and by the seasonality of flows. It was verified that costs per cubic meter of treated sewage presented a large variation from one WWTP to another, with great influence of the flow treated in the operational costs, and the Lagoons group had the lowest median of operational costs (median R$ 0.40/m³). The overall median of operational costs for all stations was R$ 0.96/m³, and the highest operating cost was R$ 4.67/m³, for WWTP 04, with a population equivalent of less than 5,000 inhabitants and whose treatment is performed by UASB reactor. The lowest operating cost was R$ 0.13/m³, for the WWTP 43, with a population equivalent of over 50,000 inhabitants and a treatment process by UASB reactors followed by trickling filters. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-07-09 2019-11-18T17:06:34Z 2019-11-18T17:06:34Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1843/31029 |
url |
http://hdl.handle.net/1843/31029 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais Brasil ENG - DEPARTAMENTO DE ENGENHARIA SANITÁRIA E AMBIENTAL Programa de Pós-Graduação em Saneamento, Meio Ambiente e Recursos Hídricos UFMG |
publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais Brasil ENG - DEPARTAMENTO DE ENGENHARIA SANITÁRIA E AMBIENTAL Programa de Pós-Graduação em Saneamento, Meio Ambiente e Recursos Hídricos UFMG |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFMG instname:Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
instname_str |
Universidade Federal de Minas Gerais (UFMG) |
instacron_str |
UFMG |
institution |
UFMG |
reponame_str |
Repositório Institucional da UFMG |
collection |
Repositório Institucional da UFMG |
repository.name.fl_str_mv |
Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG) |
repository.mail.fl_str_mv |
repositorio@ufmg.br |
_version_ |
1823248279571267584 |