Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies
Autor(a) principal: | |
---|---|
Data de Publicação: | 2024 |
Tipo de documento: | Tese |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFPE |
dARK ID: | ark:/64986/001300000dp1v |
Texto Completo: | https://repositorio.ufpe.br/handle/123456789/56451 |
Resumo: | This study proposes the development of a Palladium-based Coplanar Waveguide (CPW) microwave sensor for the detection of Dimethyl Methylphosphonate (DMMP) gas, considering its importance in warfare security contexts. DMMP is a chemical compound commonly used in the production of nerve agents, making it a critical target for detection in military environments. The sensor was fabricated using the spin coating and lift-off method, ensuring a uniform deposition of a thin palladium layer onto a planar substrate. The interaction between palladium and DMMP leads to changes in the dielectric properties of the sensor, which can be detected using microwave techniques. These variations were processed and analyzed to identify the presence of DMMP in the environment. The sensor underwent experimental testing in a controlled environment, where S21 values were measured. Specifically, DMMP was evaluated at a concentration of 400 parts per million (ppm). It was observed that the presence of DMMP caused changes in the attenuation of the S21 parameter, demonstrating the sensor's sensitivity to the target gas. |
id |
UFPE_8d064018430fc81274e8d4ad92f6fc9b |
---|---|
oai_identifier_str |
oai:repositorio.ufpe.br:123456789/56451 |
network_acronym_str |
UFPE |
network_name_str |
Repositório Institucional da UFPE |
repository_id_str |
2221 |
spelling |
ARAÚJO, Jorge Antonio de Isasahttp://lattes.cnpq.br/9316851313191920http://lattes.cnpq.br/4933635747860906MELO, Marcos Tavares deLLAMAS-GARRO, Ignacio2024-06-10T14:48:04Z2024-06-10T14:48:04Z2024-02-02ARAÚJO, Jorge Antonio de Isasa. Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies. 2024. Tese (Doutorado em Engenharia Elétrica) – Universidade Federal de Pernambuco, Recife, 2024.https://repositorio.ufpe.br/handle/123456789/56451ark:/64986/001300000dp1vThis study proposes the development of a Palladium-based Coplanar Waveguide (CPW) microwave sensor for the detection of Dimethyl Methylphosphonate (DMMP) gas, considering its importance in warfare security contexts. DMMP is a chemical compound commonly used in the production of nerve agents, making it a critical target for detection in military environments. The sensor was fabricated using the spin coating and lift-off method, ensuring a uniform deposition of a thin palladium layer onto a planar substrate. The interaction between palladium and DMMP leads to changes in the dielectric properties of the sensor, which can be detected using microwave techniques. These variations were processed and analyzed to identify the presence of DMMP in the environment. The sensor underwent experimental testing in a controlled environment, where S21 values were measured. Specifically, DMMP was evaluated at a concentration of 400 parts per million (ppm). It was observed that the presence of DMMP caused changes in the attenuation of the S21 parameter, demonstrating the sensor's sensitivity to the target gas.CAPESEste trabalho propõe o desenvolvimento de um sensor CPW de micro-ondas baseado em paládio para detecção do gás Metilfosfonato de dimetilo (DMMP), considerando sua importância para a segurança em contextos de guerra. O DMMP é um composto químico frequentemente utilizado na produção de agentes nervosos, tornando-se um alvo crítico para detecção em ambientes militares. O sensor foi fabricado por meio do método de spin coating e lift off, garantindo uma deposição uniforme da camada fina de paládio sobre um substrato planar. A interação entre o paládio e o DMMP resulta em mudanças nas propriedades dielétricas do sensor, que podem ser detectadas por meio de técnicas de micro-ondas. Essas variações foram então processadas e analisadas para identificar a presença do DMMP no ambiente. O sensor foi submetido a testes experimentais em um ambiente controlado, nos quais foram medidos os valores de S21. Em particular, o DMMP foi avaliado em uma concentração de 400 partes por milhão (ppm). Observou-se que a presença de DMMP causou alterações na atenuação do parâmetro S21, demonstrando a sensibilidade do sensor ao gás em questão.engUniversidade Federal de PernambucoPrograma de Pos Graduacao em Engenharia EletricaUFPEBrasilAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessEngenharia ElétricaMetilfosfonato de dimetiloMicro-ondasPaládioSegurançaSensorCoplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequenciesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisdoutoradoreponame:Repositório Institucional da UFPEinstname:Universidade Federal de Pernambuco (UFPE)instacron:UFPEORIGINALTESE Jorge Antonio de Isasa Araujo.pdfTESE Jorge Antonio de Isasa Araujo.pdfapplication/pdf13029350https://repositorio.ufpe.br/bitstream/123456789/56451/1/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf4eff381a6d4b0df3b7358b474876cfcbMD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufpe.br/bitstream/123456789/56451/2/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82362https://repositorio.ufpe.br/bitstream/123456789/56451/3/license.txt5e89a1613ddc8510c6576f4b23a78973MD53TEXTTESE Jorge Antonio de Isasa Araujo.pdf.txtTESE Jorge Antonio de Isasa Araujo.pdf.txtExtracted texttext/plain115408https://repositorio.ufpe.br/bitstream/123456789/56451/4/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf.txt2c3924d97edb52cca6990927ce5e4d0dMD54THUMBNAILTESE Jorge Antonio de Isasa Araujo.pdf.jpgTESE Jorge Antonio de Isasa Araujo.pdf.jpgGenerated Thumbnailimage/jpeg1234https://repositorio.ufpe.br/bitstream/123456789/56451/5/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf.jpgc0727d91466294d37d061fb5118f652fMD55123456789/564512024-06-11 02:23:51.802oai:repositorio.ufpe.br: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Repositório InstitucionalPUBhttps://repositorio.ufpe.br/oai/requestattena@ufpe.bropendoar:22212024-06-11T05:23:51Repositório Institucional da UFPE - Universidade Federal de Pernambuco (UFPE)false |
dc.title.pt_BR.fl_str_mv |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
title |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
spellingShingle |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies ARAÚJO, Jorge Antonio de Isasa Engenharia Elétrica Metilfosfonato de dimetilo Micro-ondas Paládio Segurança Sensor |
title_short |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
title_full |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
title_fullStr |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
title_full_unstemmed |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
title_sort |
Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies |
author |
ARAÚJO, Jorge Antonio de Isasa |
author_facet |
ARAÚJO, Jorge Antonio de Isasa |
author_role |
author |
dc.contributor.authorLattes.pt_BR.fl_str_mv |
http://lattes.cnpq.br/9316851313191920 |
dc.contributor.advisorLattes.pt_BR.fl_str_mv |
http://lattes.cnpq.br/4933635747860906 |
dc.contributor.author.fl_str_mv |
ARAÚJO, Jorge Antonio de Isasa |
dc.contributor.advisor1.fl_str_mv |
MELO, Marcos Tavares de |
dc.contributor.advisor-co1.fl_str_mv |
LLAMAS-GARRO, Ignacio |
contributor_str_mv |
MELO, Marcos Tavares de LLAMAS-GARRO, Ignacio |
dc.subject.por.fl_str_mv |
Engenharia Elétrica Metilfosfonato de dimetilo Micro-ondas Paládio Segurança Sensor |
topic |
Engenharia Elétrica Metilfosfonato de dimetilo Micro-ondas Paládio Segurança Sensor |
description |
This study proposes the development of a Palladium-based Coplanar Waveguide (CPW) microwave sensor for the detection of Dimethyl Methylphosphonate (DMMP) gas, considering its importance in warfare security contexts. DMMP is a chemical compound commonly used in the production of nerve agents, making it a critical target for detection in military environments. The sensor was fabricated using the spin coating and lift-off method, ensuring a uniform deposition of a thin palladium layer onto a planar substrate. The interaction between palladium and DMMP leads to changes in the dielectric properties of the sensor, which can be detected using microwave techniques. These variations were processed and analyzed to identify the presence of DMMP in the environment. The sensor underwent experimental testing in a controlled environment, where S21 values were measured. Specifically, DMMP was evaluated at a concentration of 400 parts per million (ppm). It was observed that the presence of DMMP caused changes in the attenuation of the S21 parameter, demonstrating the sensor's sensitivity to the target gas. |
publishDate |
2024 |
dc.date.accessioned.fl_str_mv |
2024-06-10T14:48:04Z |
dc.date.available.fl_str_mv |
2024-06-10T14:48:04Z |
dc.date.issued.fl_str_mv |
2024-02-02 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
ARAÚJO, Jorge Antonio de Isasa. Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies. 2024. Tese (Doutorado em Engenharia Elétrica) – Universidade Federal de Pernambuco, Recife, 2024. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufpe.br/handle/123456789/56451 |
dc.identifier.dark.fl_str_mv |
ark:/64986/001300000dp1v |
identifier_str_mv |
ARAÚJO, Jorge Antonio de Isasa. Coplanar waveguide sensor for Dimethyl Methylphosphonate gas detection at microwave frequencies. 2024. Tese (Doutorado em Engenharia Elétrica) – Universidade Federal de Pernambuco, Recife, 2024. ark:/64986/001300000dp1v |
url |
https://repositorio.ufpe.br/handle/123456789/56451 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal de Pernambuco |
dc.publisher.program.fl_str_mv |
Programa de Pos Graduacao em Engenharia Eletrica |
dc.publisher.initials.fl_str_mv |
UFPE |
dc.publisher.country.fl_str_mv |
Brasil |
publisher.none.fl_str_mv |
Universidade Federal de Pernambuco |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFPE instname:Universidade Federal de Pernambuco (UFPE) instacron:UFPE |
instname_str |
Universidade Federal de Pernambuco (UFPE) |
instacron_str |
UFPE |
institution |
UFPE |
reponame_str |
Repositório Institucional da UFPE |
collection |
Repositório Institucional da UFPE |
bitstream.url.fl_str_mv |
https://repositorio.ufpe.br/bitstream/123456789/56451/1/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf https://repositorio.ufpe.br/bitstream/123456789/56451/2/license_rdf https://repositorio.ufpe.br/bitstream/123456789/56451/3/license.txt https://repositorio.ufpe.br/bitstream/123456789/56451/4/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf.txt https://repositorio.ufpe.br/bitstream/123456789/56451/5/TESE%20Jorge%20Antonio%20de%20Isasa%20Araujo.pdf.jpg |
bitstream.checksum.fl_str_mv |
4eff381a6d4b0df3b7358b474876cfcb e39d27027a6cc9cb039ad269a5db8e34 5e89a1613ddc8510c6576f4b23a78973 2c3924d97edb52cca6990927ce5e4d0d c0727d91466294d37d061fb5118f652f |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFPE - Universidade Federal de Pernambuco (UFPE) |
repository.mail.fl_str_mv |
attena@ufpe.br |
_version_ |
1815172800471629824 |