Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica

Detalhes bibliográficos
Autor(a) principal: Almeida, Rui Manuel de Sousa Sequeira Antunes de
Data de Publicação: 2000
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/8513
Resumo: Orientador: Danton R. da Rocha Loures
id UFPR_6faa8598eae6f35ad7d626c3f8ae210b
oai_identifier_str oai:acervodigital.ufpr.br:1884/8513
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Clínica CirúrgicaLoures, Danton Richlin da RochaAlmeida, Rui Manuel de Sousa Sequeira Antunes de2022-11-11T11:15:38Z2022-11-11T11:15:38Z2000https://hdl.handle.net/1884/8513Orientador: Danton R. da Rocha LouresTese (doutorado) - Universidade Federal do Paraná, Setor de Ciencias da Saúde, Programa de Pós-Graduaçao em Clínica Cirúrgica. Defesa: Curitiba, 2000Inclui bibliografiaResumo: No período de maio de 1996 a outubro de 1997, no Serviço de Cirurgia Cardiovascular, do Hospital Policlínica de Cascavel, foram estudados 34 pacientes: nos quais se procedeu ao implante, em posição aórtica, da prótese valvular metálica de duplo folheto, giratória (ATS Medical Open Pivot™, tipo Standard), da qual se descrevem as partes componentes, pormenorizadamente. Destes 34 pacientes, 28 eram do sexo masculino e seis do feminino, com uma média de idade de 40,2 anos. No pré-operatório, 11 pacientes encontravam-se na classe funcional IV (32,4%), da NYHA, 15 na III (44,1%) e oito na II (23,5%), tendo sido realizadas 24 cirurgias eletivas, 12 de urgência e quatro de emergência. Houve um seguimento efetivo, por um ano, em 97,1%. Os pacientes foram avaliados, no pré- e no pós-operatório, através de anamnése, exames físico e laboratoriais, que incluíram exames hematológicos (VG, Hb, TAP, DHL), eletrocardiograma, radiografia do tórax e ecocardiograma bidimensional com Doppler colorido, com o objetivo de se obterem os seguintes dados: FE, EP, volumes sistólico e diastólico finais do VE, velocidades máxima e média do fluxo sangüíneo aórtico, gradientes máximo e médio transvalvular aórtico, e espessura de paredes septal e posterior de VE. A mortalidade hospitalar foi de 5,9%, devida a causas não cardíacas, e a complicação mais frequente foi a insuficiência do VE (14,7%). A mortalidade tardia foi de 3,1%. As curvas atuariais, ao final de um ano, mostraram 90,9%, de sobrevida dos pacientes, e 93,9%, de próteses livres de complicações. No final do estudo 29 pacientes estavam em classe funcional I. O índice cardiotorácico, superior a 0,5 em 91,2% dos pacientes, no pré-operatório, retornou a valores normais em 73,3%. Foi possível durante o estudo manter os pacientes com um INR entre 1,5 e 2, sem complicações relacionadas com a prótese. A DHL teve valores superiores aos normais, durante 0 acompanhamento, mas demonstrou ser um bom parâmetro de análise da hemólise sérica. O gradiente médio das próteses implantadas, ao final de um ano, foi de 12,2 ± 5,9 mmHg. Houve melhora dos índices de regressão ventricular, em todo o estudo, como sejam os volumes sistólico e diastólico finais e a espessura das paredes, do VE. Verificou-se uma correlação entre o gradiente máximo transvalvular e a DHL, bem como entre o VSF e a FE. Finalmente constatou-se que apenas uma pequena porcentagem de pacientes mencionou perturbações com o ruído da prótese. Pode-se concluir que a prótese ATS Medical Open Pivot™ é uma excelente alternativa, como substituto valvular aórtico, porque teve um baixo índice de complicações associadas, durante o período de estudo, com a vantagem de poder manter um nível de INR abaixo, dos anteriormente usados, e que ocorre o remodelamento do VE, em função do seu bom desempenho hemodinâmico.Abstract: Between May 1996 and October 1997, at the "Serviço de Cirurgia Cardiovascular" of the "Hospital Policlínica de Cascavel", 34 patients were submitted to an aortic valve replacement, by a bileaflet mechanical, rotational, heart valve (ATS Medical Open Pivot™, Standard type), from which the main parts are thoroughly described. From this group, of 34 patients, there were 28 male and 6 female with a mean age of 40.2 years. Preoperatlvely, 11 patients were in NYHA functional class IV (32.4%), 15 in class III (44.1%) and eight in class II (23.5%), being 24 elective procedures, 12 urgent and four emergencies. The group, was followed-up, for a year, in 97.1%. All patients were studied pre and postoperatively, by an interview, physical and laboratory exams, which included blood exams (globular volume, haematocrit, protrombin time and lactic dehydrogenase LDH), EKG, chest X-ray and 2-D echo Doppler color, with a purpose of getting the following data: ejection fraction, percentual shortening, left ventricular end systolic and diastolic volumes, maximum and medium aortic velocity flow, maximum and medium transvalvular gradient and septal and posterior left ventricular wall thickness. The hospital mortality was 5.9%, due to non-cardiac causes and the most important complication was left ventricular failure (14.7%). The late mortality was 3.1%. The actuarial survival curves, at the end of one year, showed a 90.9% patient survival and a 93.9% freedom of valvular problems. At the end of the study, 29 patients were in NYHA class I. The cardio-thoracic index, greater than 0.5 in 91.2% of the patients, pre-operatively, return to normal values in 73.3%. It was possible to maintain the INR values between 1.5 and 2.0, without any prostheses complications. The LDH values I were above the normal range, during the follow-up period, but was a reliable parameter for seric hemolysis. The mean valvular gradient was 12.2 ± 5.9 mmHg. There was a left ventricular remodelling, during the all study, with the regression of the systolic and diastolic left ventricular volumes and the thickness off the septal and parietal. There was a correlation between the maximum transvalvular gradient and the LDH, as well as between end systolic volume and the ejection fraction. Finally, there was only a small group of patients, who complained about the valve noise. This study is able to conclude, that the ATS Medical Open Pivot™ is a excellent alternative, for an aortic valve substitute, as it has a low index of complications, during the follow-up period, with the advantage of being able to have a low INR, comparing with other prostheses, and that a reshaping of the left ventricle occurs due to its good haemodynamic performance.127f. : il. color.application/pdfDisponível em formato digitalCirurgiaImplante de próteseTesesAplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórticainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALRUI MANUEL DE SOUSA SEQUEIRA ANTUNES DE ALMEIDA_2000.pdfapplication/pdf26243623https://acervodigital.ufpr.br/bitstream/1884/8513/1/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf4aa7b12faaaee0feea5421eb8e69f0b5MD51open accessTEXTRUI MANUEL DE SOUSA SEQUEIRA ANTUNES DE ALMEIDA_2000.pdf.txtExtracted Texttext/plain198903https://acervodigital.ufpr.br/bitstream/1884/8513/2/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf.txteb23c319f4cc85be32cb20858c679e1fMD52open accessTHUMBNAILRUI MANUEL DE SOUSA SEQUEIRA ANTUNES DE ALMEIDA_2000.pdf.jpgGenerated Thumbnailimage/jpeg1229https://acervodigital.ufpr.br/bitstream/1884/8513/3/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf.jpg1303d72bfd010a7c33afb78a563cf428MD53open access1884/85132022-11-11 08:15:38.99open accessoai:acervodigital.ufpr.br:1884/8513Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082022-11-11T11:15:38Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
title Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
spellingShingle Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
Almeida, Rui Manuel de Sousa Sequeira Antunes de
Cirurgia
Implante de prótese
Teses
title_short Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
title_full Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
title_fullStr Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
title_full_unstemmed Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
title_sort Aplicaçao clínica de prótese mecânica, de duplo folheto, giratória, em posiçao aórtica
author Almeida, Rui Manuel de Sousa Sequeira Antunes de
author_facet Almeida, Rui Manuel de Sousa Sequeira Antunes de
author_role author
dc.contributor.other.pt_BR.fl_str_mv Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Clínica Cirúrgica
dc.contributor.advisor1.fl_str_mv Loures, Danton Richlin da Rocha
dc.contributor.author.fl_str_mv Almeida, Rui Manuel de Sousa Sequeira Antunes de
contributor_str_mv Loures, Danton Richlin da Rocha
dc.subject.por.fl_str_mv Cirurgia
Implante de prótese
Teses
topic Cirurgia
Implante de prótese
Teses
description Orientador: Danton R. da Rocha Loures
publishDate 2000
dc.date.issued.fl_str_mv 2000
dc.date.accessioned.fl_str_mv 2022-11-11T11:15:38Z
dc.date.available.fl_str_mv 2022-11-11T11:15:38Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/8513
url https://hdl.handle.net/1884/8513
dc.language.iso.fl_str_mv por
language por
dc.relation.pt_BR.fl_str_mv Disponível em formato digital
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 127f. : il. color.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/8513/1/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf
https://acervodigital.ufpr.br/bitstream/1884/8513/2/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf.txt
https://acervodigital.ufpr.br/bitstream/1884/8513/3/RUI%20MANUEL%20DE%20SOUSA%20SEQUEIRA%20ANTUNES%20DE%20ALMEIDA_2000.pdf.jpg
bitstream.checksum.fl_str_mv 4aa7b12faaaee0feea5421eb8e69f0b5
eb23c319f4cc85be32cb20858c679e1f
1303d72bfd010a7c33afb78a563cf428
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1801860600174739456