Avaliação da confiabilidade analítica de medições de turbidez em água potável

Detalhes bibliográficos
Autor(a) principal: Marques, Guilherme Souza
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/46483
Resumo: Orientador: Prof. Dr. Jörg Wolfgang Metzger
id UFPR_f2ce97589f209283a847fb3f8bf62549
oai_identifier_str oai:acervodigital.ufpr.br:1884/46483
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Amaral, Karen Juliana do, 1976-Possetti, Gustavo Rafael CollereUniversidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Meio Ambiente Urbano e IndustrialSENAI. Departamento Regional do ParanáUniversität StuttgartMetzger, JorgMarques, Guilherme Souza2024-04-19T18:32:48Z2024-04-19T18:32:48Z2016https://hdl.handle.net/1884/46483Orientador: Prof. Dr. Jörg Wolfgang MetzgerCoorientadores: Profª. Drª. Karen Juliana do Amaral e Prof. Dr. Gustavo Rafael Collere PossettiDissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 04/11/2016Inclui referências: f. 101-105Resumo: A qualidade da água distribuída à população apresenta impactos diretos na área da saúde. Ciente disso o Ministério da Saúde (MS), mediante a Portaria 2914/11, exige que os parâmetros de controle da água potável sejam determinados dentro de um sistema de qualidade nos moldes da NBR ISO/IEC 17025. Um dos itens de maior relevância nessa norma é a determinação da incerteza de medição, pois apresenta uma informação quantitativa sobre a confiabilidade de um resultado de medição. Um dos parâmetros de controle exigidos pela portaria do MS é a turbidez, que está diretamente ligada a garantia de um processo efetivo de desinfeção da água, tanto que o MS reduziu o valor máximo permissível (VMP) de 1,0 NTU para 0,5 NTU, e em determinados casos é exigido um VMP de 0,3 NTU. Nesse contexto, este trabalho se propõe a avaliar a confiabilidade analítica da medição da turbidez a partir da determinação da incerteza de medição de 11 padrões de formazina e 5 amostras de água para consumo humano, todos analisados em 6 turbidímetros diferentes provenientes de 3 fabricantes distintos: D, C e P. Para tanto desenvolveu-se o cálculo da incerteza de medição da turbidez com base no Guia para a Expressão da Incerteza de Medição e avaliou-se a capacidade analítica e a compatibilidade metrológica de cada turbidímetro. Dessa forma, identificaram-se as principais fontes de incerteza do processo de medição da turbidez e todas as equações necessárias para a sua determinação. Adicionalmente, desenvolveu-se uma ferramenta para auxiliar no cálculo da incerteza desse parâmetro, a qual fornece um certificado de calibração para o turbidímetro avaliado e define uma faixa de operação para o sistema de tratamento de água garantindo a conformidade da água produzida por ele em relação às exigências da Portaria 2914/11 do MS. A partir do cálculo de incerteza de medição verificou-se que a fonte que mais contribui para a incerteza de medição da turbidez é a curva de calibração. As maiores incertezas expandidas entre os padrões analisados, considerando um nível de 99,73%, apresentaram um valor médio de 0,05 NTU para os equipamentos de marca C, 0,11 NTU para os equipamentos da marca D e 0,44 NTU para o equipamento da marca P. Foi possível afirmar a compatibilidade metrológica entre os equipamentos da marca D e C em praticamente todos os resultados, ressalvando somente determinações abaixo de 0,1 NTU para o equipamento D1, onde essa afirmativa se torna duvidosa. Os resultados obtidos permitem afirmar que somente os equipamentos da marca C e D apresentam resultados com a confiabilidade analítica necessária para afirmar a conformidade da água potável em relação à turbidez.Abstract: The quality of water distributed to the population has direct impacts on health. Aware of this, the Ministry of Health (MS), through Ordinance 2914/11, requires that the drinking water control parameters must be determined within a quality system along the lines of ISO / IEC 17025. One of the most relevant items in this standard is the determination of measurement uncertainty, because it presents quantitative information about the reliability of a measurement result. One of the control parameters required by MS is the turbidity, which is directly linked to ensure an effective process of disinfection of the water, so that the MS reduced the maximum permissible value (VMP) of 1.0 to 0.5 NTU, and in certain cases it required a VMP of 0.3 NTU. In this context, this study aims to evaluate the analytical reliability of the measurement of turbidity from the determination of the uncertainty of measurement of 11 formazin standards and 5 samples of water for human consumption, all analyzed in 6 different turbidimeters from 3 different manufacturers: D, C and P. Therefore was developed the calculation of the turbidity measurement uncertainty based on the Guide to the Expression of Uncertainty in Measurement and evaluated the analytical capacity and metrological compatibility of each turbidimeter. Thus, it were identified the main sources of uncertainty of the measurement process for turbidity and all the necessary equations for their determination. In addition, it was developed a tool to assist in the calculation of the uncertainty of this parameter, which provides a calibration certificate for the assessed turbidimeter and defines an operating range for the water treatment system to ensure compliance of the produced water regarding the requirements of MS Ordinance 2914/11. From the measurement uncertainty calculation it was found that the source that most contributes to the turbidity measurement uncertainty is the calibration curve. The greatest expanded uncertainty between the standards analyzed, considering a level of 99,73%, had an average of 0.05 NTU equipment for manufacturer C, 0,11 NTU for the equipment D brand and 0.44 NTU the equipment P. It was possible to affirm metrological compatibility of the brand D equipment and C in almost all results, excepting only determinations below 0.1 NTU for D1 equipment where this statement becomes doubtful. The results allow us to affirm that only the C and D brand equipment present results with the analytical reliability required to assert the conformity of drinking water regarding turbidity.120p. : il., algumas color., grafs., tabs.application/pdfDisponível em formato digitalPlanejamento Urbano e RegionalÁgua - QualidadeÁgua potávelAbastecimento de águaAvaliação da confiabilidade analítica de medições de turbidez em água potávelinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - D - GUILHERME SOUZA MARQUES.pdfapplication/pdf3162180https://acervodigital.ufpr.br/bitstream/1884/46483/1/R%20-%20D%20-%20GUILHERME%20SOUZA%20MARQUES.pdf62caf65d36c51337bb00021107859505MD51open access1884/464832024-04-19 15:32:48.56open accessoai:acervodigital.ufpr.br:1884/46483Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082024-04-19T18:32:48Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Avaliação da confiabilidade analítica de medições de turbidez em água potável
title Avaliação da confiabilidade analítica de medições de turbidez em água potável
spellingShingle Avaliação da confiabilidade analítica de medições de turbidez em água potável
Marques, Guilherme Souza
Planejamento Urbano e Regional
Água - Qualidade
Água potável
Abastecimento de água
title_short Avaliação da confiabilidade analítica de medições de turbidez em água potável
title_full Avaliação da confiabilidade analítica de medições de turbidez em água potável
title_fullStr Avaliação da confiabilidade analítica de medições de turbidez em água potável
title_full_unstemmed Avaliação da confiabilidade analítica de medições de turbidez em água potável
title_sort Avaliação da confiabilidade analítica de medições de turbidez em água potável
author Marques, Guilherme Souza
author_facet Marques, Guilherme Souza
author_role author
dc.contributor.other.pt_BR.fl_str_mv Amaral, Karen Juliana do, 1976-
Possetti, Gustavo Rafael Collere
Universidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Meio Ambiente Urbano e Industrial
SENAI. Departamento Regional do Paraná
Universität Stuttgart
dc.contributor.advisor1.fl_str_mv Metzger, Jorg
dc.contributor.author.fl_str_mv Marques, Guilherme Souza
contributor_str_mv Metzger, Jorg
dc.subject.por.fl_str_mv Planejamento Urbano e Regional
Água - Qualidade
Água potável
Abastecimento de água
topic Planejamento Urbano e Regional
Água - Qualidade
Água potável
Abastecimento de água
description Orientador: Prof. Dr. Jörg Wolfgang Metzger
publishDate 2016
dc.date.issued.fl_str_mv 2016
dc.date.accessioned.fl_str_mv 2024-04-19T18:32:48Z
dc.date.available.fl_str_mv 2024-04-19T18:32:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/46483
url https://hdl.handle.net/1884/46483
dc.language.iso.fl_str_mv por
language por
dc.relation.pt_BR.fl_str_mv Disponível em formato digital
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 120p. : il., algumas color., grafs., tabs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/46483/1/R%20-%20D%20-%20GUILHERME%20SOUZA%20MARQUES.pdf
bitstream.checksum.fl_str_mv 62caf65d36c51337bb00021107859505
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898811886534656