Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano

Detalhes bibliográficos
Autor(a) principal: Montin, Elisa de Freitas
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/81576
Resumo: Orientador: Prof. Dr. Fábio Seigi Murakami
id UFPR_fb6b9aca5b4c0ac67a541cfaafe73993
oai_identifier_str oai:acervodigital.ufpr.br:1884/81576
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Francisco, Thaís Martins Guimarães de, 1976-Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Ciências FarmacêuticasMurakami, Fábio Seigi, 1981-Montin, Elisa de Freitas2024-02-08T16:00:02Z2024-02-08T16:00:02Z2020https://hdl.handle.net/1884/81576Orientador: Prof. Dr. Fábio Seigi MurakamiCoorientadora: Prof.ª Dr.ª Thais Martins GuimarãesDissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Ciências Farmacêuticas. Defesa : Curitiba, 12/03/2020Inclui referências: p. 78-84Área de concentração: Medicamentos, Insumos e CorrelatosResumo: A terapia medicamentosa deve ser considerada para pacientes com diabetes mellitus tipo 2 (DM2) que não alcançam o controle glicêmico mesmo após a alteração no estilo de vida. Dentre as opções disponíveis destaca-se o fosfato monohidratado de sitagliptina (STG). A adesão terapêutica do paciente é fundamental para sua qualidade de vida. Uma das alternativas para aumentar a adesão ao tratamento, é adaptar as formulações existentes. O desenvolvimento de uma nova forma farmacêutica contendo STG pode alterar suas características farmacocinéticas, fazendo-se necessário o estudo comparativo entre as formulações. Para este fim, é necessário que a metodologia bioanalítica seja capaz de quantificar o STG em intervalos de concentração plasmática adequadas. Assim, o presente estudo teve como objetivo desenvolver, validar e aplicar um método por cromatografia líquida de alta eficiência acoplada a espectrometria de massas (CLAE - EM/EM) para a quantificação do STG em plasma humano. As análises foram realizadas utilizando o sistema CLAE Agilent 1200, acoplado ao espectrômetro de massas Triplo Quadrupolo Applied Biosystems API 3200, com fonte de ionização electrospray, operando no modo positivo de ionização. Após o desenvolvimento, o método foi validado de acordo com as normativas nacional e internacional vigentes. O método foi realizado em coluna Zorbax Eclipse Plus C18 (2,1 x 50 mm, 3,5 µm) acoplada a uma pré-coluna Zorbax Eclipse Plus C18 (2,1 x 12,5 mm, 5 µm), mantidas a 35 ºC. A fase móvel consistiu em água e acetonitrila, ambas contendo 0,1% de ácido fórmico, com eluição gradiente. O fluxo foi mantido em 0,3 mL/min. O volume de injeção foi de 20 µL. O método desenvolvido mostrou-se seletivo, livre de efeito residual e de matriz. O baixo limite de quantificação indicou que o método é sensível (LIQ = 1,5 ng/mL). As curvas de calibração apresentaram uma correlação (r >= 0,99) nas faixas de 1,5 a 500 ng/mL para a sitagliptina. O método foi preciso (CV < 13,1%) e exato (EPR < 11,8%). A recuperação da sitagliptina e do padrão interno (fluconazol) > 90%. A estabilidade dos analitos foi observada tanto em plasma quanto em solução. A aplicabilidade do método foi demonstrada por meio de um estudo farmacocinético parcial, entre duas formulações contendo sitagliptina, sendo adequado ao objetivo proposto.Abstract: Drug therapy should be considered for patients with type 2 diabetes mellitus (DM2) who do not achieve glycemic control even after changes in lifestyle. Among the options available, sitagliptin phosphate monohydrate (STG) stands out. The patient's therapeutic adherence is fundamental to his quality of life. One of the alternatives to increase adherence to treatment is to adapt existing formulations. The development of a new pharmaceutical form containing STG can alter its pharmacokinetic characteristics, making a comparative study between formulations necessary. For this purpose, it is necessary that the bioanalytical methodology is able to quantify the STG in appropriate plasma concentration ranges. Thus, the present study aimed to develop, validate and apply a high performance liquid chromatography method coupled to mass spectrometry (HPLC-EM/EM) for the quantification of STG in human plasma. The analyzes were performed using the CLAE Agilent 1200 system, coupled to the Applied Biosystems API 3200 Triple Quadrupole mass spectrometer, with electrospray ionization source, operating in the positive ionization mode. After development, the method was validated according to the national and international regulations in force. The method was performed on a Zorbax Eclipse Plus C18 column (2.1 x 50 mm, 3.5 µm) coupled to a Zorbax Eclipse Plus C18 column (2.1 x 12.5 mm, 5 µm), maintained at 35 ºC. The mobile phase consisted of water and acetonitrile, both containing 0.1% formic acid, with gradient elution. The flow was maintained at 0.3 ml/min. The injection volume was 20 µL. The method developed was selective, free of residual and matrix effects. The low limit of quantification indicated that the method is sensitive (LLQ = 1.5 ng/mL). The calibration curves showed a correlation (r >= 0.99) in the 1.5 to 500 ng / mL ranges for sitagliptin. The method was precise (CV < 13.1%) and accurate (SE < 11.8%). Recovery of sitagliptin and internal pattern (fluconazole) > 90%. Analyte stability was observed in both plasma and solution. The applicability of the method was demonstrated by means of a partial pharmacokinetic study, between two formulations containing sitagliptin, being adequate to the proposed objective.1 recurso online : PDF.application/pdfCromatografia liquida de alta eficienciaEspectrometria de massaFarmacocinéticaFarmáciaDesenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humanoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - D - ELISA DE FREITAS MONTIN.pdfapplication/pdf2132879https://acervodigital.ufpr.br/bitstream/1884/81576/1/R%20-%20D%20-%20ELISA%20DE%20FREITAS%20MONTIN.pdf3742a92464b63d00e5467e1c2363a5d3MD51open access1884/815762024-02-08 13:00:03.016open accessoai:acervodigital.ufpr.br:1884/81576Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082024-02-08T16:00:03Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
title Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
spellingShingle Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
Montin, Elisa de Freitas
Cromatografia liquida de alta eficiencia
Espectrometria de massa
Farmacocinética
Farmácia
title_short Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
title_full Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
title_fullStr Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
title_full_unstemmed Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
title_sort Desenvolvimento e validação de método por CLAE-EM/EM para quantificação de sitagliptina em plasma humano
author Montin, Elisa de Freitas
author_facet Montin, Elisa de Freitas
author_role author
dc.contributor.other.pt_BR.fl_str_mv Francisco, Thaís Martins Guimarães de, 1976-
Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Ciências Farmacêuticas
dc.contributor.advisor1.fl_str_mv Murakami, Fábio Seigi, 1981-
dc.contributor.author.fl_str_mv Montin, Elisa de Freitas
contributor_str_mv Murakami, Fábio Seigi, 1981-
dc.subject.por.fl_str_mv Cromatografia liquida de alta eficiencia
Espectrometria de massa
Farmacocinética
Farmácia
topic Cromatografia liquida de alta eficiencia
Espectrometria de massa
Farmacocinética
Farmácia
description Orientador: Prof. Dr. Fábio Seigi Murakami
publishDate 2020
dc.date.issued.fl_str_mv 2020
dc.date.accessioned.fl_str_mv 2024-02-08T16:00:02Z
dc.date.available.fl_str_mv 2024-02-08T16:00:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/81576
url https://hdl.handle.net/1884/81576
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1 recurso online : PDF.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/81576/1/R%20-%20D%20-%20ELISA%20DE%20FREITAS%20MONTIN.pdf
bitstream.checksum.fl_str_mv 3742a92464b63d00e5467e1c2363a5d3
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898915528835072