Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist

Detalhes bibliográficos
Autor(a) principal: Pilling, Betiane Moreira
Data de Publicação: 2024
Outros Autores: Candotti, Cláudia Tarragô, Silva, Marcelle Guimarães, Frantz, Marina Ziegler, Noll, Matias
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFRGS
Texto Completo: http://hdl.handle.net/10183/279957
Resumo: With the enforcement of social distancing due to the pandemic, a need to conduct postural assessments through remote care arose. So, this study aimed to assess the intra- and interrater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s Postural Checklist. The study involved 51 participants, with the postural assessment conducted by two researchers. For intra-rater reproducibility assessment, one rater administered the ARPE protocol twice, with an interval of 7–days between assessments (test–retest). A second independent rater assessed inter-rater reproducibility. Kappa statistics (k) and percentage agreement (%C) were used, with a significance level of 0.05. The intra-rater reproducibility analysis indicated high reliability, k values varied from 0.921 to 1.0, with %C ranging from 94% to 100% for all items on the ARPE protocol’s Postural Checklist. Interrater reproducibility indicates reliability ranging from slight to good, k values exceeded 0.4 for the entire checklist, except for four items: waists in the frontal photograph (k = 0.353), scapulae in the rear photograph (k = 0.310), popliteal line of the knees in the rear photograph (k = 0.270), and foot posture in the rear photograph (k = 0.271). Nonetheless, %C surpassed 50% for all but the scapulae item (%C = 47%). The ARPE protocol’s Postural Checklist is reproducible and can be administered by the same or different raters for static posture assessment. However, when used by distinct raters, the items waists (front of the frontal plane), scapulae, popliteal line of the knees, and feet (rear of the frontal plane) should not be considered.
id UFRGS-2_d914cccd906292e50b8516a2f2d1cf86
oai_identifier_str oai:www.lume.ufrgs.br:10183/279957
network_acronym_str UFRGS-2
network_name_str Repositório Institucional da UFRGS
repository_id_str
spelling Pilling, Betiane MoreiraCandotti, Cláudia TarragôSilva, Marcelle GuimarãesFrantz, Marina ZieglerNoll, Matias2024-10-15T06:40:49Z20241932-6203http://hdl.handle.net/10183/279957001196775With the enforcement of social distancing due to the pandemic, a need to conduct postural assessments through remote care arose. So, this study aimed to assess the intra- and interrater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s Postural Checklist. The study involved 51 participants, with the postural assessment conducted by two researchers. For intra-rater reproducibility assessment, one rater administered the ARPE protocol twice, with an interval of 7–days between assessments (test–retest). A second independent rater assessed inter-rater reproducibility. Kappa statistics (k) and percentage agreement (%C) were used, with a significance level of 0.05. The intra-rater reproducibility analysis indicated high reliability, k values varied from 0.921 to 1.0, with %C ranging from 94% to 100% for all items on the ARPE protocol’s Postural Checklist. Interrater reproducibility indicates reliability ranging from slight to good, k values exceeded 0.4 for the entire checklist, except for four items: waists in the frontal photograph (k = 0.353), scapulae in the rear photograph (k = 0.310), popliteal line of the knees in the rear photograph (k = 0.270), and foot posture in the rear photograph (k = 0.271). Nonetheless, %C surpassed 50% for all but the scapulae item (%C = 47%). The ARPE protocol’s Postural Checklist is reproducible and can be administered by the same or different raters for static posture assessment. However, when used by distinct raters, the items waists (front of the frontal plane), scapulae, popliteal line of the knees, and feet (rear of the frontal plane) should not be considered.application/pdfengPloS one. San Francisco. Vol. 19, no. 2 (Feb. 2024), e0297506, 10 p.PosturaInstrumentos de avaliaçãoTelerreabilitaçãoPandemia de COVID-19 (2020-)Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklistEstrangeiroinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRGSinstname:Universidade Federal do Rio Grande do Sul (UFRGS)instacron:UFRGSTEXT001196775.pdf.txt001196775.pdf.txtExtracted Texttext/plain38918http://www.lume.ufrgs.br/bitstream/10183/279957/2/001196775.pdf.txtc59aa03f877a260eead828deb944eb2cMD52ORIGINAL001196775.pdfTexto completo (inglês)application/pdf552033http://www.lume.ufrgs.br/bitstream/10183/279957/1/001196775.pdfc5c33682323f5c174fa87e093b82d884MD5110183/2799572024-10-16 06:56:15.48125oai:www.lume.ufrgs.br:10183/279957Repositório de PublicaçõesPUBhttps://lume.ufrgs.br/oai/requestopendoar:2024-10-16T09:56:15Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)false
dc.title.pt_BR.fl_str_mv Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
title Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
spellingShingle Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
Pilling, Betiane Moreira
Postura
Instrumentos de avaliação
Telerreabilitação
Pandemia de COVID-19 (2020-)
title_short Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
title_full Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
title_fullStr Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
title_full_unstemmed Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
title_sort Intra and inter-rater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s postural checklist
author Pilling, Betiane Moreira
author_facet Pilling, Betiane Moreira
Candotti, Cláudia Tarragô
Silva, Marcelle Guimarães
Frantz, Marina Ziegler
Noll, Matias
author_role author
author2 Candotti, Cláudia Tarragô
Silva, Marcelle Guimarães
Frantz, Marina Ziegler
Noll, Matias
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Pilling, Betiane Moreira
Candotti, Cláudia Tarragô
Silva, Marcelle Guimarães
Frantz, Marina Ziegler
Noll, Matias
dc.subject.por.fl_str_mv Postura
Instrumentos de avaliação
Telerreabilitação
Pandemia de COVID-19 (2020-)
topic Postura
Instrumentos de avaliação
Telerreabilitação
Pandemia de COVID-19 (2020-)
description With the enforcement of social distancing due to the pandemic, a need to conduct postural assessments through remote care arose. So, this study aimed to assess the intra- and interrater reproducibility of the Remote Static Posture Assessment (ARPE) protocol’s Postural Checklist. The study involved 51 participants, with the postural assessment conducted by two researchers. For intra-rater reproducibility assessment, one rater administered the ARPE protocol twice, with an interval of 7–days between assessments (test–retest). A second independent rater assessed inter-rater reproducibility. Kappa statistics (k) and percentage agreement (%C) were used, with a significance level of 0.05. The intra-rater reproducibility analysis indicated high reliability, k values varied from 0.921 to 1.0, with %C ranging from 94% to 100% for all items on the ARPE protocol’s Postural Checklist. Interrater reproducibility indicates reliability ranging from slight to good, k values exceeded 0.4 for the entire checklist, except for four items: waists in the frontal photograph (k = 0.353), scapulae in the rear photograph (k = 0.310), popliteal line of the knees in the rear photograph (k = 0.270), and foot posture in the rear photograph (k = 0.271). Nonetheless, %C surpassed 50% for all but the scapulae item (%C = 47%). The ARPE protocol’s Postural Checklist is reproducible and can be administered by the same or different raters for static posture assessment. However, when used by distinct raters, the items waists (front of the frontal plane), scapulae, popliteal line of the knees, and feet (rear of the frontal plane) should not be considered.
publishDate 2024
dc.date.accessioned.fl_str_mv 2024-10-15T06:40:49Z
dc.date.issued.fl_str_mv 2024
dc.type.driver.fl_str_mv Estrangeiro
info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10183/279957
dc.identifier.issn.pt_BR.fl_str_mv 1932-6203
dc.identifier.nrb.pt_BR.fl_str_mv 001196775
identifier_str_mv 1932-6203
001196775
url http://hdl.handle.net/10183/279957
dc.language.iso.fl_str_mv eng
language eng
dc.relation.ispartof.pt_BR.fl_str_mv PloS one. San Francisco. Vol. 19, no. 2 (Feb. 2024), e0297506, 10 p.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRGS
instname:Universidade Federal do Rio Grande do Sul (UFRGS)
instacron:UFRGS
instname_str Universidade Federal do Rio Grande do Sul (UFRGS)
instacron_str UFRGS
institution UFRGS
reponame_str Repositório Institucional da UFRGS
collection Repositório Institucional da UFRGS
bitstream.url.fl_str_mv http://www.lume.ufrgs.br/bitstream/10183/279957/2/001196775.pdf.txt
http://www.lume.ufrgs.br/bitstream/10183/279957/1/001196775.pdf
bitstream.checksum.fl_str_mv c59aa03f877a260eead828deb944eb2c
c5c33682323f5c174fa87e093b82d884
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)
repository.mail.fl_str_mv
_version_ 1815447866221527040