A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFRGS |
Texto Completo: | http://hdl.handle.net/10183/212746 |
Resumo: | High impedance faults (HIFs) have been a major concern for protecting distribution systems and public safety hazards when involving downed conductors. The deployment of smarter grids brings new technologies for smart monitoring, automation, and protection of distribution networks. This paper presents a new method for a series of HIF detection and location in primary distribution feeders, using voltage unbalance measurements collected from smart meters (SMs) installed at low-voltage end-users. The methodology was tested in MATLAB and Simulink through steady-state simulations of a typical 13.8 kV distribution system, under load unbalance and di erent fault scenarios. Results show that the proposed method is robust and accurate for the detection of blown fuses and broken conductors, with or without ground faults, located either at the source or the load-side. The ease of implementation in SM design, formulation of parameters, and reliable simulation results show potential real-life applications. |
id |
UFRGS-2_dcf6768e4e629e840eb939350363a409 |
---|---|
oai_identifier_str |
oai:www.lume.ufrgs.br:10183/212746 |
network_acronym_str |
UFRGS-2 |
network_name_str |
Repositório Institucional da UFRGS |
repository_id_str |
|
spelling |
Vieira, Francinei LucasSantos, Pedro H. M. dosCarvalho Filho, José Maria deLeborgne, Roberto ChouhyLeite, Marino Piazza2020-08-08T03:46:08Z20191996-1073http://hdl.handle.net/10183/212746001115026High impedance faults (HIFs) have been a major concern for protecting distribution systems and public safety hazards when involving downed conductors. The deployment of smarter grids brings new technologies for smart monitoring, automation, and protection of distribution networks. This paper presents a new method for a series of HIF detection and location in primary distribution feeders, using voltage unbalance measurements collected from smart meters (SMs) installed at low-voltage end-users. The methodology was tested in MATLAB and Simulink through steady-state simulations of a typical 13.8 kV distribution system, under load unbalance and di erent fault scenarios. Results show that the proposed method is robust and accurate for the detection of blown fuses and broken conductors, with or without ground faults, located either at the source or the load-side. The ease of implementation in SM design, formulation of parameters, and reliable simulation results show potential real-life applications.application/pdfengEnergies. Basel. Vol. 12, no. 15 (Aug. 2019), 16 p.FalhasImpedância elétricaEnergia elétrica : DistribuiçãoMedidor elétricoTensão elétricaHigh impedance faultFault locationDistribution networkSmartmetersVoltage unbalanceA voltage-based approach for series high impedance fault detection and location in distribution systems using smart metersEstrangeiroinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRGSinstname:Universidade Federal do Rio Grande do Sul (UFRGS)instacron:UFRGSTEXT001115026.pdf.txt001115026.pdf.txtExtracted Texttext/plain50326http://www.lume.ufrgs.br/bitstream/10183/212746/2/001115026.pdf.txt5ffe88c01880d48d75e4477458d495ecMD52ORIGINAL001115026.pdfTexto completo (inglês)application/pdf1492595http://www.lume.ufrgs.br/bitstream/10183/212746/1/001115026.pdf02f0fdf33468d9009cbaa146067ac241MD5110183/2127462020-08-09 03:33:02.324487oai:www.lume.ufrgs.br:10183/212746Repositório de PublicaçõesPUBhttps://lume.ufrgs.br/oai/requestopendoar:2020-08-09T06:33:02Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)false |
dc.title.pt_BR.fl_str_mv |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
title |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
spellingShingle |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters Vieira, Francinei Lucas Falhas Impedância elétrica Energia elétrica : Distribuição Medidor elétrico Tensão elétrica High impedance fault Fault location Distribution network Smartmeters Voltage unbalance |
title_short |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
title_full |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
title_fullStr |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
title_full_unstemmed |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
title_sort |
A voltage-based approach for series high impedance fault detection and location in distribution systems using smart meters |
author |
Vieira, Francinei Lucas |
author_facet |
Vieira, Francinei Lucas Santos, Pedro H. M. dos Carvalho Filho, José Maria de Leborgne, Roberto Chouhy Leite, Marino Piazza |
author_role |
author |
author2 |
Santos, Pedro H. M. dos Carvalho Filho, José Maria de Leborgne, Roberto Chouhy Leite, Marino Piazza |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Vieira, Francinei Lucas Santos, Pedro H. M. dos Carvalho Filho, José Maria de Leborgne, Roberto Chouhy Leite, Marino Piazza |
dc.subject.por.fl_str_mv |
Falhas Impedância elétrica Energia elétrica : Distribuição Medidor elétrico Tensão elétrica |
topic |
Falhas Impedância elétrica Energia elétrica : Distribuição Medidor elétrico Tensão elétrica High impedance fault Fault location Distribution network Smartmeters Voltage unbalance |
dc.subject.eng.fl_str_mv |
High impedance fault Fault location Distribution network Smartmeters Voltage unbalance |
description |
High impedance faults (HIFs) have been a major concern for protecting distribution systems and public safety hazards when involving downed conductors. The deployment of smarter grids brings new technologies for smart monitoring, automation, and protection of distribution networks. This paper presents a new method for a series of HIF detection and location in primary distribution feeders, using voltage unbalance measurements collected from smart meters (SMs) installed at low-voltage end-users. The methodology was tested in MATLAB and Simulink through steady-state simulations of a typical 13.8 kV distribution system, under load unbalance and di erent fault scenarios. Results show that the proposed method is robust and accurate for the detection of blown fuses and broken conductors, with or without ground faults, located either at the source or the load-side. The ease of implementation in SM design, formulation of parameters, and reliable simulation results show potential real-life applications. |
publishDate |
2019 |
dc.date.issued.fl_str_mv |
2019 |
dc.date.accessioned.fl_str_mv |
2020-08-08T03:46:08Z |
dc.type.driver.fl_str_mv |
Estrangeiro info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10183/212746 |
dc.identifier.issn.pt_BR.fl_str_mv |
1996-1073 |
dc.identifier.nrb.pt_BR.fl_str_mv |
001115026 |
identifier_str_mv |
1996-1073 001115026 |
url |
http://hdl.handle.net/10183/212746 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.pt_BR.fl_str_mv |
Energies. Basel. Vol. 12, no. 15 (Aug. 2019), 16 p. |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRGS instname:Universidade Federal do Rio Grande do Sul (UFRGS) instacron:UFRGS |
instname_str |
Universidade Federal do Rio Grande do Sul (UFRGS) |
instacron_str |
UFRGS |
institution |
UFRGS |
reponame_str |
Repositório Institucional da UFRGS |
collection |
Repositório Institucional da UFRGS |
bitstream.url.fl_str_mv |
http://www.lume.ufrgs.br/bitstream/10183/212746/2/001115026.pdf.txt http://www.lume.ufrgs.br/bitstream/10183/212746/1/001115026.pdf |
bitstream.checksum.fl_str_mv |
5ffe88c01880d48d75e4477458d495ec 02f0fdf33468d9009cbaa146067ac241 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS) |
repository.mail.fl_str_mv |
|
_version_ |
1801224996653105152 |