Osseointegration evaluation of plasma nitrided titanium implants
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFRN |
Texto Completo: | https://repositorio.ufrn.br/jspui/handle/123456789/29625 |
Resumo: | There is a need for new techniques that modify metallic implant surfaces, resulting in good bone response for low density areas. Among the different techniques, plasma nitriding is being applied in biomedicine with excellent results. However, its use in titanium dental implants is very limited owing to high process temperatures (between 700 and 800°C) that result in distortions. In order to solve this problem, the authors used a new plasma method with a hollow cathode discharge configuration. Ti grade II dental implants were nitrided in a 20% N2–H2 atmosphere at a temperature of 450°C, 150 Pa (1·5 mbar), for 1 h and inserted into rabbit tibias to assess osseointegration. The results showed that plasma nitriding caused a significant change in the surface texture of the nitrided implants and greater removal torque than that of the control implants |
id |
UFRN_36e44973eee756a7bc4206e8bd226749 |
---|---|
oai_identifier_str |
oai:https://repositorio.ufrn.br:123456789/29625 |
network_acronym_str |
UFRN |
network_name_str |
Repositório Institucional da UFRN |
repository_id_str |
|
spelling |
Guerra Neto, Custódio Leopoldino de BritoSilva, Marco Aurélio Medeiros daAlves Júnior, Clodomiro2020-07-14T23:19:36Z2020-07-14T23:19:36Z2009GUERRA NETO, C. L. B.; SILVA, M. A. M. ; ALVES JUNIOR, C.. Osseointegration evaluation of plasma nitrided titanium implants. Surface Engineering, v. 25, p. 434-439, 2009. Disponível em: https://www.tandfonline.com/doi/abs/10.1179/174329409X389272. Acesso em: 13 jul. 2020. https://doi.org/10.1179/174329409X3892720267-0844https://repositorio.ufrn.br/jspui/handle/123456789/2962510.1179/174329409X389272Surface EngineeringAttribution-NonCommercial-NoDerivs 3.0 Brazilhttp://creativecommons.org/licenses/by-nc-nd/3.0/br/info:eu-repo/semantics/openAccessOsseointegrationDental implantsSurface modificationsPlasma nitridingBiomaterialsOsseointegration evaluation of plasma nitrided titanium implantsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleThere is a need for new techniques that modify metallic implant surfaces, resulting in good bone response for low density areas. Among the different techniques, plasma nitriding is being applied in biomedicine with excellent results. However, its use in titanium dental implants is very limited owing to high process temperatures (between 700 and 800°C) that result in distortions. In order to solve this problem, the authors used a new plasma method with a hollow cathode discharge configuration. Ti grade II dental implants were nitrided in a 20% N2–H2 atmosphere at a temperature of 450°C, 150 Pa (1·5 mbar), for 1 h and inserted into rabbit tibias to assess osseointegration. The results showed that plasma nitriding caused a significant change in the surface texture of the nitrided implants and greater removal torque than that of the control implantsengreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdfOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdfapplication/pdf825046https://repositorio.ufrn.br/bitstream/123456789/29625/1/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf0ace8d320c48904041b0c6887d0ef0c3MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.ufrn.br/bitstream/123456789/29625/2/license_rdfe39d27027a6cc9cb039ad269a5db8e34MD52TEXTOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.txtOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.txtExtracted texttext/plain19805https://repositorio.ufrn.br/bitstream/123456789/29625/4/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.txt1c3d83e5db30575c36296cd5dabbe072MD54THUMBNAILOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.jpgOsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.jpgGenerated Thumbnailimage/jpeg1464https://repositorio.ufrn.br/bitstream/123456789/29625/5/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.jpg4562eae91c18d5d87ff3940c3c3d4ddeMD55LICENSElicense.txtlicense.txttext/plain; charset=utf-81484https://repositorio.ufrn.br/bitstream/123456789/29625/3/license.txte9597aa2854d128fd968be5edc8a28d9MD53123456789/296252020-10-02 10:08:21.091oai:https://repositorio.ufrn.br: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Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2020-10-02T13:08:21Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false |
dc.title.pt_BR.fl_str_mv |
Osseointegration evaluation of plasma nitrided titanium implants |
title |
Osseointegration evaluation of plasma nitrided titanium implants |
spellingShingle |
Osseointegration evaluation of plasma nitrided titanium implants Guerra Neto, Custódio Leopoldino de Brito Osseointegration Dental implants Surface modifications Plasma nitriding Biomaterials |
title_short |
Osseointegration evaluation of plasma nitrided titanium implants |
title_full |
Osseointegration evaluation of plasma nitrided titanium implants |
title_fullStr |
Osseointegration evaluation of plasma nitrided titanium implants |
title_full_unstemmed |
Osseointegration evaluation of plasma nitrided titanium implants |
title_sort |
Osseointegration evaluation of plasma nitrided titanium implants |
author |
Guerra Neto, Custódio Leopoldino de Brito |
author_facet |
Guerra Neto, Custódio Leopoldino de Brito Silva, Marco Aurélio Medeiros da Alves Júnior, Clodomiro |
author_role |
author |
author2 |
Silva, Marco Aurélio Medeiros da Alves Júnior, Clodomiro |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Guerra Neto, Custódio Leopoldino de Brito Silva, Marco Aurélio Medeiros da Alves Júnior, Clodomiro |
dc.subject.por.fl_str_mv |
Osseointegration Dental implants Surface modifications Plasma nitriding Biomaterials |
topic |
Osseointegration Dental implants Surface modifications Plasma nitriding Biomaterials |
description |
There is a need for new techniques that modify metallic implant surfaces, resulting in good bone response for low density areas. Among the different techniques, plasma nitriding is being applied in biomedicine with excellent results. However, its use in titanium dental implants is very limited owing to high process temperatures (between 700 and 800°C) that result in distortions. In order to solve this problem, the authors used a new plasma method with a hollow cathode discharge configuration. Ti grade II dental implants were nitrided in a 20% N2–H2 atmosphere at a temperature of 450°C, 150 Pa (1·5 mbar), for 1 h and inserted into rabbit tibias to assess osseointegration. The results showed that plasma nitriding caused a significant change in the surface texture of the nitrided implants and greater removal torque than that of the control implants |
publishDate |
2009 |
dc.date.issued.fl_str_mv |
2009 |
dc.date.accessioned.fl_str_mv |
2020-07-14T23:19:36Z |
dc.date.available.fl_str_mv |
2020-07-14T23:19:36Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
GUERRA NETO, C. L. B.; SILVA, M. A. M. ; ALVES JUNIOR, C.. Osseointegration evaluation of plasma nitrided titanium implants. Surface Engineering, v. 25, p. 434-439, 2009. Disponível em: https://www.tandfonline.com/doi/abs/10.1179/174329409X389272. Acesso em: 13 jul. 2020. https://doi.org/10.1179/174329409X389272 |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufrn.br/jspui/handle/123456789/29625 |
dc.identifier.issn.none.fl_str_mv |
0267-0844 |
dc.identifier.doi.none.fl_str_mv |
10.1179/174329409X389272 |
identifier_str_mv |
GUERRA NETO, C. L. B.; SILVA, M. A. M. ; ALVES JUNIOR, C.. Osseointegration evaluation of plasma nitrided titanium implants. Surface Engineering, v. 25, p. 434-439, 2009. Disponível em: https://www.tandfonline.com/doi/abs/10.1179/174329409X389272. Acesso em: 13 jul. 2020. https://doi.org/10.1179/174329409X389272 0267-0844 10.1179/174329409X389272 |
url |
https://repositorio.ufrn.br/jspui/handle/123456789/29625 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Surface Engineering |
publisher.none.fl_str_mv |
Surface Engineering |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte (UFRN) instacron:UFRN |
instname_str |
Universidade Federal do Rio Grande do Norte (UFRN) |
instacron_str |
UFRN |
institution |
UFRN |
reponame_str |
Repositório Institucional da UFRN |
collection |
Repositório Institucional da UFRN |
bitstream.url.fl_str_mv |
https://repositorio.ufrn.br/bitstream/123456789/29625/1/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf https://repositorio.ufrn.br/bitstream/123456789/29625/2/license_rdf https://repositorio.ufrn.br/bitstream/123456789/29625/4/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.txt https://repositorio.ufrn.br/bitstream/123456789/29625/5/OsseointegrationEvaluationOfPlasma_GuerraNeto_2009.pdf.jpg https://repositorio.ufrn.br/bitstream/123456789/29625/3/license.txt |
bitstream.checksum.fl_str_mv |
0ace8d320c48904041b0c6887d0ef0c3 e39d27027a6cc9cb039ad269a5db8e34 1c3d83e5db30575c36296cd5dabbe072 4562eae91c18d5d87ff3940c3c3d4dde e9597aa2854d128fd968be5edc8a28d9 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN) |
repository.mail.fl_str_mv |
|
_version_ |
1814832893338320896 |