Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFRN |
Texto Completo: | https://repositorio.ufrn.br/jspui/handle/123456789/13326 |
Resumo: | OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesions |
id |
UFRN_6226936905740acdd2262d5462d635bf |
---|---|
oai_identifier_str |
oai:https://repositorio.ufrn.br:123456789/13326 |
network_acronym_str |
UFRN |
network_name_str |
Repositório Institucional da UFRN |
repository_id_str |
|
spelling |
Souza, Eliel dehttp://lattes.cnpq.br/9777545117488122http://lattes.cnpq.br/7869140767244263Pinheiro, Luiz Gonzaga Portohttp://lattes.cnpq.br/4121910252334757Oliveira, Ana Katherine da Silveira Gonçalves dehttp://lattes.cnpq.br/34367563372514492014-12-17T14:13:50Z2011-05-132014-12-17T14:13:50Z2010-10-17SOUZA, Eliel de. Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental. 2010. 112 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal do Rio Grande do Norte, Natal, 2010.https://repositorio.ufrn.br/jspui/handle/123456789/13326OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesionsOBJETIVO: avaliar o desempenho do Kit Bh na realização de biopsias mamárias. MÉTODOS: de fevereiro de 2008 a abril de 2010, com base nos resultados de um estudo piloto, selecionou-se aleatoriamente uma amostra composta de 30 pacientes portadoras de câncer de mama submetidas a mastectomia. Excluíram-se as mulheres portadoras de tumor que tivesse consistência pétrea, não palpável, com manipulação cirúrgica prévia ou que contivesse líquido. Utilizando-se o Kit de biopsia helicóide ( Kit Bh ) e um equipamentos de Core biopsy com cânula e agulha de 14 gauge respectivamente, coletou-se um fragmento por equipamento em área sã e nos tumores, em cada peça cirúrgica, totalizando 120 fragmentos para estudo histológico. Para a análise dos dados definiu-se um nível de confiança de 95% e utilizou-se o software SPSS-versão 13, o índice de concordância Kappa e o teste paramétrico t de Student. RESULTADOS: a média das idades das pacientes foi de 51,6 anos (± 11,1 anos). O Carcinoma ductal infiltrante apresentou maior incidência, 26 casos (86,7%). A Core biopsy apresentou sensibilidade de 93,3%, especificidade de 100% e acurácia de 96,7%, enquanto a Biopsia helicóide teve sensibilidade de 96,7%, especificidade de 100% e acurácia de 98,3%. Na comparação entre a histologia dos tumores e dos fragmentos de biopsias houve alto grau de concordância nos diagnósticos ( Kappa igual a 0,93 com p<0,05) CONCLUSÕES: ambos os equipamentos proporcionaram o diagnóstico histológico das lesões com alta acurácia.Os resultados deste estudo demonstraram que a biopsia helicóide é uma alternativa confiável no diagnostico pré-operatório de lesões mamárias. Estudos mais aprofundados in vivo, definirão melhor o papel do Kit Bh no diagnóstico dessas lesõesapplication/pdfporUniversidade Federal do Rio Grande do NortePrograma de Pós-Graduação em Ciências da SaúdeUFRNBRCiências da SaúdeCâncer de mamaBiopsia por agulhaCâncer da mamaCâncer mamárioNeoplasias mamáriasTumores da mamaBreast cancerNeedle BiopsyBreast neoplasiesBreastTumoursMammary cancerCNPQ::CIENCIAS DA SAUDEAbordagem inicial de lesões mamárias por biopsia helicóide: estudo experimentalinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALAbordagemInicialLesoes_Souza_2010.pdfAbordagemInicialLesoes_Souza_2010.pdfapplication/pdf5628434https://repositorio.ufrn.br/bitstream/123456789/13326/1/AbordagemInicialLesoes_Souza_2010.pdfa5e1d026ad0b0a3024ef2a2fbd6de7baMD51TEXTElielS_DISSERT.pdf.txtElielS_DISSERT.pdf.txtExtracted texttext/plain125913https://repositorio.ufrn.br/bitstream/123456789/13326/6/ElielS_DISSERT.pdf.txt3fea9a13a46035cccf0c884e2596ef5fMD56AbordagemInicialLesoes_Souza_2010.pdf.txtAbordagemInicialLesoes_Souza_2010.pdf.txtExtracted texttext/plain125903https://repositorio.ufrn.br/bitstream/123456789/13326/8/AbordagemInicialLesoes_Souza_2010.pdf.txtb820de62318c0da7791b04f5ef34769aMD58THUMBNAILElielS_DISSERT.pdf.jpgElielS_DISSERT.pdf.jpgIM Thumbnailimage/jpeg2811https://repositorio.ufrn.br/bitstream/123456789/13326/7/ElielS_DISSERT.pdf.jpg8ee8abd11877f3c8821d0db6bfd1da3dMD57AbordagemInicialLesoes_Souza_2010.pdf.jpgAbordagemInicialLesoes_Souza_2010.pdf.jpgGenerated Thumbnailimage/jpeg1319https://repositorio.ufrn.br/bitstream/123456789/13326/9/AbordagemInicialLesoes_Souza_2010.pdf.jpgd911a41ff1deeb76b2afe126974aab26MD59123456789/133262019-05-26 02:18:58.755oai:https://repositorio.ufrn.br:123456789/13326Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2019-05-26T05:18:58Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false |
dc.title.por.fl_str_mv |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
title |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
spellingShingle |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental Souza, Eliel de Câncer de mama Biopsia por agulha Câncer da mama Câncer mamário Neoplasias mamárias Tumores da mama Breast cancer Needle Biopsy Breast neoplasies Breast Tumours Mammary cancer CNPQ::CIENCIAS DA SAUDE |
title_short |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
title_full |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
title_fullStr |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
title_full_unstemmed |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
title_sort |
Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental |
author |
Souza, Eliel de |
author_facet |
Souza, Eliel de |
author_role |
author |
dc.contributor.authorID.por.fl_str_mv |
|
dc.contributor.authorLattes.por.fl_str_mv |
http://lattes.cnpq.br/9777545117488122 |
dc.contributor.advisorID.por.fl_str_mv |
|
dc.contributor.advisorLattes.por.fl_str_mv |
http://lattes.cnpq.br/7869140767244263 |
dc.contributor.referees1.pt_BR.fl_str_mv |
Pinheiro, Luiz Gonzaga Porto |
dc.contributor.referees1ID.por.fl_str_mv |
|
dc.contributor.referees1Lattes.por.fl_str_mv |
http://lattes.cnpq.br/4121910252334757 |
dc.contributor.referees2.pt_BR.fl_str_mv |
Oliveira, Ana Katherine da Silveira Gonçalves de |
dc.contributor.referees2ID.por.fl_str_mv |
|
dc.contributor.referees2Lattes.por.fl_str_mv |
http://lattes.cnpq.br/3436756337251449 |
dc.contributor.author.fl_str_mv |
Souza, Eliel de |
dc.subject.por.fl_str_mv |
Câncer de mama Biopsia por agulha Câncer da mama Câncer mamário Neoplasias mamárias Tumores da mama |
topic |
Câncer de mama Biopsia por agulha Câncer da mama Câncer mamário Neoplasias mamárias Tumores da mama Breast cancer Needle Biopsy Breast neoplasies Breast Tumours Mammary cancer CNPQ::CIENCIAS DA SAUDE |
dc.subject.eng.fl_str_mv |
Breast cancer Needle Biopsy Breast neoplasies Breast Tumours Mammary cancer |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE |
description |
OBJECTIVE: Evaluating the kit-Bh performance in carrying out of breast biopsies. METHODS: They were randomly selected a sample of 30 patients with breast cancer undergoing mastectomy, based on the results of a pilot study from February 2008 to April 2010. They were excluded women with had not palpable, stone-hard consistency tumors, previous surgical manipulation or that contains liquid. Using the helicoid biopsy Kit (kit Bh) and an equipment Core biopsy with cannula and needle and 14 gauge respectively, it was collected a fragment of sound equipment in the area and in tumors in each specimen, totaling 120 fragments for histological study. For data analysis, it was defined a 95% confidence level and used the SPSS-13 version, the Kappa index and the parametric Student t test. RESULTS: Mean age of patients was 51.6 years (± 11.1 years). The infiltrating ductal carcinoma showed a higher incidence, 26 cases (86.7%). The Core biopsy had a sensitivity of 93.3%, specificity of 100% and accuracy 96.7%, while the helicoid biopsy had a sensitivity of 96.7%, specificity of 100% and accuracy 98.3%. By comparing the histology of tumors and the fragments of biopsies, there was high degree of agreement in diagnoses (kappa of 0.93 with p <0.05) CONCLUSION: Both devices provided the histological diagnosis of lesions with high accuracy. Results of this study showed that the helicoid biopsy is a reliable alternative in 22 the preoperative diagnosis of breast lesions. Further studies in vivo better will define the role of Kit Bh in the diagnosis of these lesions |
publishDate |
2010 |
dc.date.issued.fl_str_mv |
2010-10-17 |
dc.date.available.fl_str_mv |
2011-05-13 2014-12-17T14:13:50Z |
dc.date.accessioned.fl_str_mv |
2014-12-17T14:13:50Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
SOUZA, Eliel de. Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental. 2010. 112 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal do Rio Grande do Norte, Natal, 2010. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufrn.br/jspui/handle/123456789/13326 |
identifier_str_mv |
SOUZA, Eliel de. Abordagem inicial de lesões mamárias por biopsia helicóide: estudo experimental. 2010. 112 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal do Rio Grande do Norte, Natal, 2010. |
url |
https://repositorio.ufrn.br/jspui/handle/123456789/13326 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Ciências da Saúde |
dc.publisher.initials.fl_str_mv |
UFRN |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Ciências da Saúde |
publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte (UFRN) instacron:UFRN |
instname_str |
Universidade Federal do Rio Grande do Norte (UFRN) |
instacron_str |
UFRN |
institution |
UFRN |
reponame_str |
Repositório Institucional da UFRN |
collection |
Repositório Institucional da UFRN |
bitstream.url.fl_str_mv |
https://repositorio.ufrn.br/bitstream/123456789/13326/1/AbordagemInicialLesoes_Souza_2010.pdf https://repositorio.ufrn.br/bitstream/123456789/13326/6/ElielS_DISSERT.pdf.txt https://repositorio.ufrn.br/bitstream/123456789/13326/8/AbordagemInicialLesoes_Souza_2010.pdf.txt https://repositorio.ufrn.br/bitstream/123456789/13326/7/ElielS_DISSERT.pdf.jpg https://repositorio.ufrn.br/bitstream/123456789/13326/9/AbordagemInicialLesoes_Souza_2010.pdf.jpg |
bitstream.checksum.fl_str_mv |
a5e1d026ad0b0a3024ef2a2fbd6de7ba 3fea9a13a46035cccf0c884e2596ef5f b820de62318c0da7791b04f5ef34769a 8ee8abd11877f3c8821d0db6bfd1da3d d911a41ff1deeb76b2afe126974aab26 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN) |
repository.mail.fl_str_mv |
|
_version_ |
1814833049230114816 |