Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1590/S0100-72032007001200002 http://repositorio.unifesp.br/handle/11600/4055 |
Resumo: | PURPOSE: to assess the accuracy (rate of correct predictions) of stereotactic core needle biopsy (CNB) of risk category BI-RADS® 4 breast lesions. METHODS: a retrospective analysis of category BI-RADS® 4 breast lesions that had been submitted to a stereotactic core-needle biopsy from June 1998 to June 2003. Patients with histological benign results consistent with the radiographic image were referred to mammographic follow-up. Patients with malign diagnosis and papillary lesions were submitted to standard specific treatment. Excisional biopsies were performed when results were benign, but in disagreement with the mammographic image. It was considered as a gold-standard attendance: (1) the mammographic follow-up of low suspicion lesions with benign results at CNB, which stayed unchanged for, at least, three years, and (2) surgical resection when specimen results were malign or benign, but with a high suspicion on mammography. Sensitivity (S) specificity (E) and overall accuracy of stereotactic CNB were statistically analyzed. RESULTS: among the 118 non-palpable lesions of category BI-RADS® 4 submitted to CNB, the results obtained were: 27 malign cases, 81 benign, and ten lesions with atypical or papillary lesions. The statistical analysis comprised 108 patients (atypical and papillary lesions were excluded). CNB sensitivity was 87.1% and specificity 100%. The positive predictive value was 100% and the negative, 95.1%. False negatives occurred in 3.7% (4/108) of cases. The prevalence of malign diagnostics in the BI-RADS® 4 lesions of this sample was 29.7 (31/118).The accuracy of this method in this casuistic was 96.3%. CONCLUSIONS: these results support stereotactic CNB as an extremely reliable alternative to open biopsy, in the diagnosis and definition of breast lesions. In positive results, it is possible to indicate the appropriate therapy, and, in negative (when mammography shows low suspicion), it allows a follow up. |
id |
UFSP_2e73b548e2a4d2f66f165908c33b6af1 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/4055 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4Diagnostic accuracy of stereotactic core-needle biopsy of non-palpable breast lesions categorized as BI-RADS® 4MammographyBreastBreast neoplasmsBiopsy needleStereotaxic techniquesMamografiaMamaNeoplasias mamáriasBiopsia por agulhaTécnicas estereotáxicasPURPOSE: to assess the accuracy (rate of correct predictions) of stereotactic core needle biopsy (CNB) of risk category BI-RADS® 4 breast lesions. METHODS: a retrospective analysis of category BI-RADS® 4 breast lesions that had been submitted to a stereotactic core-needle biopsy from June 1998 to June 2003. Patients with histological benign results consistent with the radiographic image were referred to mammographic follow-up. Patients with malign diagnosis and papillary lesions were submitted to standard specific treatment. Excisional biopsies were performed when results were benign, but in disagreement with the mammographic image. It was considered as a gold-standard attendance: (1) the mammographic follow-up of low suspicion lesions with benign results at CNB, which stayed unchanged for, at least, three years, and (2) surgical resection when specimen results were malign or benign, but with a high suspicion on mammography. Sensitivity (S) specificity (E) and overall accuracy of stereotactic CNB were statistically analyzed. RESULTS: among the 118 non-palpable lesions of category BI-RADS® 4 submitted to CNB, the results obtained were: 27 malign cases, 81 benign, and ten lesions with atypical or papillary lesions. The statistical analysis comprised 108 patients (atypical and papillary lesions were excluded). CNB sensitivity was 87.1% and specificity 100%. The positive predictive value was 100% and the negative, 95.1%. False negatives occurred in 3.7% (4/108) of cases. The prevalence of malign diagnostics in the BI-RADS® 4 lesions of this sample was 29.7 (31/118).The accuracy of this method in this casuistic was 96.3%. CONCLUSIONS: these results support stereotactic CNB as an extremely reliable alternative to open biopsy, in the diagnosis and definition of breast lesions. In positive results, it is possible to indicate the appropriate therapy, and, in negative (when mammography shows low suspicion), it allows a follow up.OBJETIVO: avaliar a acurácia da biópsia com agulha grossa (BAG) orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4. MÉTODOS: realizou-se uma análise retrospectiva das lesões categoria BI-RADS® 4 que foram submetidas à BAG orientada por estereotaxia no período de junho de 1998 a junho de 2003. As pacientes com resultados benignos, mas com baixa suspeição à imagem radiográfica, foram orientadas a acompanhamento mamográfico. As pacientes com resultados malignos ou com lesões especiais (atipias e lesões papilíferas) foram submetidas ao tratamento padronizado. Aquelas com resultado benigno, mas que apresentavam imagem mamográfica de maior risco, foram encaminhadas para biópsia cirúrgica (BC). Foram considerados padrão-ouro (1) o acompanhamento radiográfico inalterado por, no mínimo, três anos daquelas lesões de baixa suspeição que resultaram benigno na BAG e (2) os resultados das biópsias cirúrgicas, quando essas foram realizadas (nas BAG cujos resultados foram malignos ou benignos com imagem de maior risco). Foram realizados os cálculos estatísticos de sensibilidade, especificidade e valor preditivo positivo e negativo do método. RESULTADOS: das 118 lesões não palpáveis categoria BI-RADS® 4 submetidas à BAG orientada por estereotaxia, 27 casos correspondiam à doença maligna, 81 eram benignas e 10 eram lesões com atipia ou papilíferas. Para a análise estatística, foram selecionados 108 pacientes (excluídas as lesões com atipia e papilíferas). A sensibilidade da BAG foi de 87,1% e a especificidade foi de 100%. O valor preditivo positivo foi de 100% e o negativo, de 95,1%. A acurácia da BAG nessa casuística foi de 96,3%. A taxa de falso-negativo foi de 3,7% (4/108). A prevalência de diagnóstico de malignidade nas lesões BI-RADS® 4 nessa amostra foi de 29,7% (31/118). CONCLUSÕES: a biópsia estereotáxica com agulha grossa mostrou-se uma alternativa segura à BC. Quando seu resultado é positivo, orienta o planejamento terapêutico, e, quando negativo (em imagens radiográficas de baixa suspeição), permite o acompanhamento.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de GinecologiaUniversidade de São Paulo Departamento de GinecologiaUNIFESP, EPM, Depto. de GinecologiaSciELOFederação Brasileira das Sociedades de Ginecologia e ObstetríciaUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Moutinho, Maria Silvia Petty [UNIFESP]Elias, Simone [UNIFESP]Kemp, Claudio [UNIFESP]Nazário, Afonso Celso Pinto [UNIFESP]Baracat, Edmund Chada [UNIFESP]2015-06-14T13:37:15Z2015-06-14T13:37:15Z2007-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion608-613application/pdfhttp://dx.doi.org/10.1590/S0100-72032007001200002Revista Brasileira de Ginecologia e Obstetrícia. Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, v. 29, n. 12, p. 608-613, 2007.10.1590/S0100-72032007001200002S0100-72032007001200002.pdf0100-7203S0100-72032007001200002http://repositorio.unifesp.br/handle/11600/4055porRevista Brasileira de Ginecologia e Obstetríciainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T14:02:06Zoai:repositorio.unifesp.br/:11600/4055Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-28T14:02:06Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 Diagnostic accuracy of stereotactic core-needle biopsy of non-palpable breast lesions categorized as BI-RADS® 4 |
title |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
spellingShingle |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 Moutinho, Maria Silvia Petty [UNIFESP] Mammography Breast Breast neoplasms Biopsy needle Stereotaxic techniques Mamografia Mama Neoplasias mamárias Biopsia por agulha Técnicas estereotáxicas |
title_short |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
title_full |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
title_fullStr |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
title_full_unstemmed |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
title_sort |
Acurácia diagnóstica da biópsia percutânea com agulha grossa orientada por estereotaxia nas lesões mamárias categoria BI-RADS® 4 |
author |
Moutinho, Maria Silvia Petty [UNIFESP] |
author_facet |
Moutinho, Maria Silvia Petty [UNIFESP] Elias, Simone [UNIFESP] Kemp, Claudio [UNIFESP] Nazário, Afonso Celso Pinto [UNIFESP] Baracat, Edmund Chada [UNIFESP] |
author_role |
author |
author2 |
Elias, Simone [UNIFESP] Kemp, Claudio [UNIFESP] Nazário, Afonso Celso Pinto [UNIFESP] Baracat, Edmund Chada [UNIFESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Moutinho, Maria Silvia Petty [UNIFESP] Elias, Simone [UNIFESP] Kemp, Claudio [UNIFESP] Nazário, Afonso Celso Pinto [UNIFESP] Baracat, Edmund Chada [UNIFESP] |
dc.subject.por.fl_str_mv |
Mammography Breast Breast neoplasms Biopsy needle Stereotaxic techniques Mamografia Mama Neoplasias mamárias Biopsia por agulha Técnicas estereotáxicas |
topic |
Mammography Breast Breast neoplasms Biopsy needle Stereotaxic techniques Mamografia Mama Neoplasias mamárias Biopsia por agulha Técnicas estereotáxicas |
description |
PURPOSE: to assess the accuracy (rate of correct predictions) of stereotactic core needle biopsy (CNB) of risk category BI-RADS® 4 breast lesions. METHODS: a retrospective analysis of category BI-RADS® 4 breast lesions that had been submitted to a stereotactic core-needle biopsy from June 1998 to June 2003. Patients with histological benign results consistent with the radiographic image were referred to mammographic follow-up. Patients with malign diagnosis and papillary lesions were submitted to standard specific treatment. Excisional biopsies were performed when results were benign, but in disagreement with the mammographic image. It was considered as a gold-standard attendance: (1) the mammographic follow-up of low suspicion lesions with benign results at CNB, which stayed unchanged for, at least, three years, and (2) surgical resection when specimen results were malign or benign, but with a high suspicion on mammography. Sensitivity (S) specificity (E) and overall accuracy of stereotactic CNB were statistically analyzed. RESULTS: among the 118 non-palpable lesions of category BI-RADS® 4 submitted to CNB, the results obtained were: 27 malign cases, 81 benign, and ten lesions with atypical or papillary lesions. The statistical analysis comprised 108 patients (atypical and papillary lesions were excluded). CNB sensitivity was 87.1% and specificity 100%. The positive predictive value was 100% and the negative, 95.1%. False negatives occurred in 3.7% (4/108) of cases. The prevalence of malign diagnostics in the BI-RADS® 4 lesions of this sample was 29.7 (31/118).The accuracy of this method in this casuistic was 96.3%. CONCLUSIONS: these results support stereotactic CNB as an extremely reliable alternative to open biopsy, in the diagnosis and definition of breast lesions. In positive results, it is possible to indicate the appropriate therapy, and, in negative (when mammography shows low suspicion), it allows a follow up. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12-01 2015-06-14T13:37:15Z 2015-06-14T13:37:15Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0100-72032007001200002 Revista Brasileira de Ginecologia e Obstetrícia. Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, v. 29, n. 12, p. 608-613, 2007. 10.1590/S0100-72032007001200002 S0100-72032007001200002.pdf 0100-7203 S0100-72032007001200002 http://repositorio.unifesp.br/handle/11600/4055 |
url |
http://dx.doi.org/10.1590/S0100-72032007001200002 http://repositorio.unifesp.br/handle/11600/4055 |
identifier_str_mv |
Revista Brasileira de Ginecologia e Obstetrícia. Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, v. 29, n. 12, p. 608-613, 2007. 10.1590/S0100-72032007001200002 S0100-72032007001200002.pdf 0100-7203 S0100-72032007001200002 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Revista Brasileira de Ginecologia e Obstetrícia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
608-613 application/pdf |
dc.publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268392747565056 |