Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos

Detalhes bibliográficos
Autor(a) principal: Valença, João Vinícius Batista
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFS
Texto Completo: https://ri.ufs.br/handle/riufs/5364
Resumo: The establishment of specific equipment with the only purpose of evaluation the breast tissue has brought important improvement in mammary cancer detection. Presenting a huge variety in its characteristics, the female breasts varies in density and also in thickness, the mammographer it is useful in many occasions, including breast with artificial implants. The goal of this work is evaluate, using as main parameters the effective atomic number (Zef) and the total mass attenuation coefficient (ì/ñ), the mixture between paraffin gel and acrylic powder as breast simulator, as well as use the best proportion of these materials to analyze the interference of the silicone implant in images. Showing a rapid manufacture procedure, and requiring low cost materials, the simulator built with the proportion Paraffin+10%acrylic , which represents the addition of 10% of acrylic in the value of the paraffin, was the one that simulated best the mammary glands. The adipose tissue, which the proximity was greater, the percentage differences obtained to ì/ñ were approximately 32,9% for 10keV, 28,5% for 15 keV, 20,2% for 20 KeV, 11,1% for 30 keV e 5,4% for 40 keV. The evaluation in terms of implant interference showed that the scattered radiation produced by it has an approximated range of 5 mm to the built simulator which was introduced a 105 mL implant. Exposures with different compressions characteristics also were made, which was clear the influence in the image with quality and less time exposure
id UFS-2_023f9dfed38e8df95a6b1f82cf12efba
oai_identifier_str oai:ufs.br:riufs/5364
network_acronym_str UFS-2
network_name_str Repositório Institucional da UFS
repository_id_str
spelling Valença, João Vinícius Batistahttp://lattes.cnpq.br/3897283209013869Souza, Divanizia do Nascimentohttp://lattes.cnpq.br/37771776470215862017-09-26T18:27:41Z2017-09-26T18:27:41Z2012-03-30https://ri.ufs.br/handle/riufs/5364The establishment of specific equipment with the only purpose of evaluation the breast tissue has brought important improvement in mammary cancer detection. Presenting a huge variety in its characteristics, the female breasts varies in density and also in thickness, the mammographer it is useful in many occasions, including breast with artificial implants. The goal of this work is evaluate, using as main parameters the effective atomic number (Zef) and the total mass attenuation coefficient (ì/ñ), the mixture between paraffin gel and acrylic powder as breast simulator, as well as use the best proportion of these materials to analyze the interference of the silicone implant in images. Showing a rapid manufacture procedure, and requiring low cost materials, the simulator built with the proportion Paraffin+10%acrylic , which represents the addition of 10% of acrylic in the value of the paraffin, was the one that simulated best the mammary glands. The adipose tissue, which the proximity was greater, the percentage differences obtained to ì/ñ were approximately 32,9% for 10keV, 28,5% for 15 keV, 20,2% for 20 KeV, 11,1% for 30 keV e 5,4% for 40 keV. The evaluation in terms of implant interference showed that the scattered radiation produced by it has an approximated range of 5 mm to the built simulator which was introduced a 105 mL implant. Exposures with different compressions characteristics also were made, which was clear the influence in the image with quality and less time exposureO estabelecimento de um equipamento especifico para avaliação da mama com uso da radiação X trouxe importantes beneficios na deteccao precoce do câncer mamário. Apresentando-se com diversas características, a mama feminina varia em relação tanto a densidade como em espessura, sendo o mamografo util em diversas analises, incluindo em mamas portadoras de implantes artificiais. O objetivo deste trabalho foi avaliar uma mistura entre parafina em gel e acrilico em po como simulador do tecido mamario, usando como parametros principais o numero atomico efetivo (Zef) e o coeficiente de atenuacao massico total ( Ê/ Ï), bem como utilizar a melhor proporcao destes para analisar a interferencia na imagem da presenca do implante de silicone. Empregando processo de confeccao rapido, e utilizando materiais de baixo valor monetario, o simulador construido com a proporcao eParafina + 10% acrilico f, que representa adicao de acrilico no valor de 10% do valor da parafina utilizado, foi aquele que melhor simulou a glandula mamaria. Em relacao ao tecido adiposo, no qual a proximidade de simulacao foi maior, as diferencas percentuais exibidas para Ê/ Ï foram de aproximadamente 32,9% para 10 keV, 28,5% para 15 keV, 20,2% para 20 keV, 11,1% para 30 keV e 5,4% para 40 keV. A avaliacao em termos da interferencia do implante de 105 mL mostrou que a radiacao espalhada por ele dentro do objeto simulador tinha um alcance aproximado de 5 mm. Exposicoes com diferentes caracteristicas de compressao tambem foram efetuadas e por meio da analise das imagens obtidas ficou evidente a influencia da compressao na obtencao de imagens com boa qualidade sendo necessario um menor tempo de exposiçãoapplication/pdfporMamas - ExameRaios X - OncologiaMamas - CâncerBreastBreastOncologyX-raysCNPQ::CIENCIAS EXATAS E DA TERRA::FISICAAvaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficosinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisPós-Graduação em Físicainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSORIGINALJOAO_VINICIUS_BATISTA_VALENCA.pdfapplication/pdf3203416https://ri.ufs.br/jspui/bitstream/riufs/5364/1/JOAO_VINICIUS_BATISTA_VALENCA.pdfec682bd43220cff466a71f2f671887f8MD51TEXTJOAO_VINICIUS_BATISTA_VALENCA.pdf.txtJOAO_VINICIUS_BATISTA_VALENCA.pdf.txtExtracted texttext/plain122914https://ri.ufs.br/jspui/bitstream/riufs/5364/2/JOAO_VINICIUS_BATISTA_VALENCA.pdf.txtf7c8b1014b41d8dbd3a41c921d9aeb11MD52THUMBNAILJOAO_VINICIUS_BATISTA_VALENCA.pdf.jpgJOAO_VINICIUS_BATISTA_VALENCA.pdf.jpgGenerated Thumbnailimage/jpeg1471https://ri.ufs.br/jspui/bitstream/riufs/5364/3/JOAO_VINICIUS_BATISTA_VALENCA.pdf.jpg2148e7f312428e7cb09ede04b1d4d25dMD53riufs/53642017-11-29 19:59:19.196oai:ufs.br:riufs/5364Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2017-11-29T22:59:19Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false
dc.title.por.fl_str_mv Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
title Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
spellingShingle Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
Valença, João Vinícius Batista
Mamas - Exame
Raios X - Oncologia
Mamas - Câncer
Breast
Breast
Oncology
X-rays
CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
title_short Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
title_full Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
title_fullStr Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
title_full_unstemmed Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
title_sort Avaliação de um simulador de mama para estudo da interferência do implante de silicone na visualização de achados mamográficos
author Valença, João Vinícius Batista
author_facet Valença, João Vinícius Batista
author_role author
dc.contributor.author.fl_str_mv Valença, João Vinícius Batista
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3897283209013869
dc.contributor.advisor1.fl_str_mv Souza, Divanizia do Nascimento
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/3777177647021586
contributor_str_mv Souza, Divanizia do Nascimento
dc.subject.por.fl_str_mv Mamas - Exame
Raios X - Oncologia
Mamas - Câncer
topic Mamas - Exame
Raios X - Oncologia
Mamas - Câncer
Breast
Breast
Oncology
X-rays
CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
dc.subject.eng.fl_str_mv Breast
Breast
Oncology
X-rays
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::FISICA
description The establishment of specific equipment with the only purpose of evaluation the breast tissue has brought important improvement in mammary cancer detection. Presenting a huge variety in its characteristics, the female breasts varies in density and also in thickness, the mammographer it is useful in many occasions, including breast with artificial implants. The goal of this work is evaluate, using as main parameters the effective atomic number (Zef) and the total mass attenuation coefficient (ì/ñ), the mixture between paraffin gel and acrylic powder as breast simulator, as well as use the best proportion of these materials to analyze the interference of the silicone implant in images. Showing a rapid manufacture procedure, and requiring low cost materials, the simulator built with the proportion Paraffin+10%acrylic , which represents the addition of 10% of acrylic in the value of the paraffin, was the one that simulated best the mammary glands. The adipose tissue, which the proximity was greater, the percentage differences obtained to ì/ñ were approximately 32,9% for 10keV, 28,5% for 15 keV, 20,2% for 20 KeV, 11,1% for 30 keV e 5,4% for 40 keV. The evaluation in terms of implant interference showed that the scattered radiation produced by it has an approximated range of 5 mm to the built simulator which was introduced a 105 mL implant. Exposures with different compressions characteristics also were made, which was clear the influence in the image with quality and less time exposure
publishDate 2012
dc.date.issued.fl_str_mv 2012-03-30
dc.date.accessioned.fl_str_mv 2017-09-26T18:27:41Z
dc.date.available.fl_str_mv 2017-09-26T18:27:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ri.ufs.br/handle/riufs/5364
url https://ri.ufs.br/handle/riufs/5364
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.program.fl_str_mv Pós-Graduação em Física
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFS
instname:Universidade Federal de Sergipe (UFS)
instacron:UFS
instname_str Universidade Federal de Sergipe (UFS)
instacron_str UFS
institution UFS
reponame_str Repositório Institucional da UFS
collection Repositório Institucional da UFS
bitstream.url.fl_str_mv https://ri.ufs.br/jspui/bitstream/riufs/5364/1/JOAO_VINICIUS_BATISTA_VALENCA.pdf
https://ri.ufs.br/jspui/bitstream/riufs/5364/2/JOAO_VINICIUS_BATISTA_VALENCA.pdf.txt
https://ri.ufs.br/jspui/bitstream/riufs/5364/3/JOAO_VINICIUS_BATISTA_VALENCA.pdf.jpg
bitstream.checksum.fl_str_mv ec682bd43220cff466a71f2f671887f8
f7c8b1014b41d8dbd3a41c921d9aeb11
2148e7f312428e7cb09ede04b1d4d25d
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)
repository.mail.fl_str_mv repositorio@academico.ufs.br
_version_ 1802110825957163008