Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFS |
Texto Completo: | https://ri.ufs.br/handle/riufs/6133 |
Resumo: | This research had as main objective to develop an electroanalytical procedure for the determination of amodiaquine in human milk, using a carbon paste electrode modified with hemin, hemoglobin functional group responsible for transporting oxygen. The amodiaquine (a derivative 4-aminoquinoquinolínico) is a drug used to treat malaria with anti-inflammatory and antipyretic properties. The characterization and preparation of carbon paste electrode modified with hemin was investigated. The electrochemical behavior of modified electrode was explored using differential pulse voltammetry. The best voltammetric response was obtained for the composition of carbon paste 10% hemin solution in Britton-Robson buffer pH 7.0. To study the electrochemical behavior of amodiaquine was used the technique of cyclic voltammetry, which presented in a neutral medium oxidation process at 0.054 V vs. Ag / AgCl at a rate of 20 mV s-1. The voltammetric techniques used to develop the methodology where the differential pulse voltammetry and square wave voltammetry. In this study the optimized conditions were: pH 7, scan rate = 40 mV s-1, amplitude = 200 mV and frequency = 150 Hz, where the parameters indicated the square wave voltammetry as the best technique for determining the voltammetric amodiaquine has a minor detection limit. The limits of detection and quantification were obtained in the determination of 8.7 x 10-7 mol L-1 and 2.9 x 10-6 mol L-1, respectively. After optimization of all relevant parameters, the analytical method developed was successfully applied in samples of breast milk. The concentration of amodiaquine obtained was 1.7 x 10-5 mol L-1. The method was efficient and reproducible in the determination of amodiaquine present in breast milk, there is no need any pretreatment of the sample. |
id |
UFS-2_ee46be411ff9b6b8cdb41a4ba07343c5 |
---|---|
oai_identifier_str |
oai:ufs.br:riufs/6133 |
network_acronym_str |
UFS-2 |
network_name_str |
Repositório Institucional da UFS |
repository_id_str |
|
spelling |
Valente, Cristiane Oliveirahttp://lattes.cnpq.br/1396973634283242Arguelho, Maria de Lara Palmeira de Macedohttp://lattes.cnpq.br/03147366827818132017-09-27T13:57:57Z2017-09-27T13:57:57Z2010-06-16VALENTE, Cristiane Oliveira. DEVELOPMENT OF A BIOSENSOR BASE FOR ANALYSIS OF HEMIN AMODIAQUINE MOTHER IN MILK. 2010. 81 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, 2010.https://ri.ufs.br/handle/riufs/6133This research had as main objective to develop an electroanalytical procedure for the determination of amodiaquine in human milk, using a carbon paste electrode modified with hemin, hemoglobin functional group responsible for transporting oxygen. The amodiaquine (a derivative 4-aminoquinoquinolínico) is a drug used to treat malaria with anti-inflammatory and antipyretic properties. The characterization and preparation of carbon paste electrode modified with hemin was investigated. The electrochemical behavior of modified electrode was explored using differential pulse voltammetry. The best voltammetric response was obtained for the composition of carbon paste 10% hemin solution in Britton-Robson buffer pH 7.0. To study the electrochemical behavior of amodiaquine was used the technique of cyclic voltammetry, which presented in a neutral medium oxidation process at 0.054 V vs. Ag / AgCl at a rate of 20 mV s-1. The voltammetric techniques used to develop the methodology where the differential pulse voltammetry and square wave voltammetry. In this study the optimized conditions were: pH 7, scan rate = 40 mV s-1, amplitude = 200 mV and frequency = 150 Hz, where the parameters indicated the square wave voltammetry as the best technique for determining the voltammetric amodiaquine has a minor detection limit. The limits of detection and quantification were obtained in the determination of 8.7 x 10-7 mol L-1 and 2.9 x 10-6 mol L-1, respectively. After optimization of all relevant parameters, the analytical method developed was successfully applied in samples of breast milk. The concentration of amodiaquine obtained was 1.7 x 10-5 mol L-1. The method was efficient and reproducible in the determination of amodiaquine present in breast milk, there is no need any pretreatment of the sample.Este trabalho teve como objetivo desenvolver uma metodologia eletroanalítica para a determinação de amodiaquina em leite materno, utilizando um biossensor a base de hemina, uma porfirina presente na hemoglobina e responável pelo transporte de oxigênio. A amodiaquina, por sua vez, é um derivado 4-aminoquinoquinolínico amplamente utilizada no tratamento da malária, com propriedades antiinflamatória e antipirética. Sua transferência para o leite materno é moderada, porém mesmo em baixas dosagens pode ser considerada prejudicial ao lactante. A caracterização e a preparo do biossensor foi a primeira etapa deste trabalho. O comportamento eletroquímico do biossensor foi explorado pelo emprego da técnica voltametria de pulso diferencial. As melhores respostas voltamétricas foram obtidas com a composição da pasta de carbono contendo 10% de hemina em solução-tampão Britton-Robson de pH 7,0. Para o estudo do comportamento eletródico da amodiaquina foi utilizada a técnica de voltametria cíclica, que apresentou em meio neutro um processo de oxidação em 0,054 V vs. Ag/AgCl na velocidade de 20 mV s-1 em pH 7,0. As técnicas voltamétricas utilizadas para o desenvolvimento da metodologia foram a voltametria de pulso diferencial e a voltametria de onda quadrada. Nesse estudo as condições otimizadas encontradas foram: pH = 7; velocidade de varredura = 40 mV s-1; amplitude = 200 mV e freqüência = 150 Hz, onde os parâmetros indicaram a voltametria de onda quadrada como a melhor técnica para a determinação voltamétrica da amodiaquina por apresentar melhor desempenho. Os limites de detecção e quantificação obtidos na determinação da amodiaquina por voltametria de onda quadrada foram de 8,7 x 10-7 mol L-1 e 2,9 x 10-6 mol L-1, respectivamente. Após a otimização de todos os parâmetros relevantes, o método analítico desenvolvido foi aplicado com sucesso em amostras de leite materno. A concentração de amodiaquina analisada foi de 1,7 x 10 -5 mol L-1. O método desenvolvido mostrou-se eficiente e reprodutível na determinação de amodiaquina presente no leite materno, não sendo necessário qualquer tratamento prévio da amostra.application/pdfporUniversidade Federal de SergipePós-Graduação em QuímicaUFSBRLeite maternoAmodiaquinaVoltametria de onda quadradaHeminaBreastfeedingAmodiaquineSquare wave voltammetryHeminCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICADesenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite maternoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSORIGINALCRISTIANE_OLIVEIRA_VALENTE.pdfapplication/pdf653421https://ri.ufs.br/jspui/bitstream/riufs/6133/1/CRISTIANE_OLIVEIRA_VALENTE.pdf8f7c5518726f5fba6c97e030be0ae0f3MD51TEXTCRISTIANE_OLIVEIRA_VALENTE.pdf.txtCRISTIANE_OLIVEIRA_VALENTE.pdf.txtExtracted texttext/plain123931https://ri.ufs.br/jspui/bitstream/riufs/6133/2/CRISTIANE_OLIVEIRA_VALENTE.pdf.txt46fc442194eaeb62459cfd80c751c508MD52THUMBNAILCRISTIANE_OLIVEIRA_VALENTE.pdf.jpgCRISTIANE_OLIVEIRA_VALENTE.pdf.jpgGenerated Thumbnailimage/jpeg1371https://ri.ufs.br/jspui/bitstream/riufs/6133/3/CRISTIANE_OLIVEIRA_VALENTE.pdf.jpg70b7a72e46a522caed7664a5bf09fb58MD53riufs/61332018-01-16 19:36:41.05oai:ufs.br:riufs/6133Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2018-01-16T22:36:41Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false |
dc.title.por.fl_str_mv |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
title |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
spellingShingle |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno Valente, Cristiane Oliveira Leite materno Amodiaquina Voltametria de onda quadrada Hemina Breastfeeding Amodiaquine Square wave voltammetry Hemin CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA |
title_short |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
title_full |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
title_fullStr |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
title_full_unstemmed |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
title_sort |
Desenvolvimento de um biossensor a base de hemina para análise de amodiaquina em leite materno |
author |
Valente, Cristiane Oliveira |
author_facet |
Valente, Cristiane Oliveira |
author_role |
author |
dc.contributor.author.fl_str_mv |
Valente, Cristiane Oliveira |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/1396973634283242 |
dc.contributor.advisor1.fl_str_mv |
Arguelho, Maria de Lara Palmeira de Macedo |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/0314736682781813 |
contributor_str_mv |
Arguelho, Maria de Lara Palmeira de Macedo |
dc.subject.por.fl_str_mv |
Leite materno Amodiaquina Voltametria de onda quadrada Hemina |
topic |
Leite materno Amodiaquina Voltametria de onda quadrada Hemina Breastfeeding Amodiaquine Square wave voltammetry Hemin CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA |
dc.subject.eng.fl_str_mv |
Breastfeeding Amodiaquine Square wave voltammetry Hemin |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA |
description |
This research had as main objective to develop an electroanalytical procedure for the determination of amodiaquine in human milk, using a carbon paste electrode modified with hemin, hemoglobin functional group responsible for transporting oxygen. The amodiaquine (a derivative 4-aminoquinoquinolínico) is a drug used to treat malaria with anti-inflammatory and antipyretic properties. The characterization and preparation of carbon paste electrode modified with hemin was investigated. The electrochemical behavior of modified electrode was explored using differential pulse voltammetry. The best voltammetric response was obtained for the composition of carbon paste 10% hemin solution in Britton-Robson buffer pH 7.0. To study the electrochemical behavior of amodiaquine was used the technique of cyclic voltammetry, which presented in a neutral medium oxidation process at 0.054 V vs. Ag / AgCl at a rate of 20 mV s-1. The voltammetric techniques used to develop the methodology where the differential pulse voltammetry and square wave voltammetry. In this study the optimized conditions were: pH 7, scan rate = 40 mV s-1, amplitude = 200 mV and frequency = 150 Hz, where the parameters indicated the square wave voltammetry as the best technique for determining the voltammetric amodiaquine has a minor detection limit. The limits of detection and quantification were obtained in the determination of 8.7 x 10-7 mol L-1 and 2.9 x 10-6 mol L-1, respectively. After optimization of all relevant parameters, the analytical method developed was successfully applied in samples of breast milk. The concentration of amodiaquine obtained was 1.7 x 10-5 mol L-1. The method was efficient and reproducible in the determination of amodiaquine present in breast milk, there is no need any pretreatment of the sample. |
publishDate |
2010 |
dc.date.issued.fl_str_mv |
2010-06-16 |
dc.date.accessioned.fl_str_mv |
2017-09-27T13:57:57Z |
dc.date.available.fl_str_mv |
2017-09-27T13:57:57Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
VALENTE, Cristiane Oliveira. DEVELOPMENT OF A BIOSENSOR BASE FOR ANALYSIS OF HEMIN AMODIAQUINE MOTHER IN MILK. 2010. 81 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, 2010. |
dc.identifier.uri.fl_str_mv |
https://ri.ufs.br/handle/riufs/6133 |
identifier_str_mv |
VALENTE, Cristiane Oliveira. DEVELOPMENT OF A BIOSENSOR BASE FOR ANALYSIS OF HEMIN AMODIAQUINE MOTHER IN MILK. 2010. 81 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, 2010. |
url |
https://ri.ufs.br/handle/riufs/6133 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Sergipe |
dc.publisher.program.fl_str_mv |
Pós-Graduação em Química |
dc.publisher.initials.fl_str_mv |
UFS |
dc.publisher.country.fl_str_mv |
BR |
publisher.none.fl_str_mv |
Universidade Federal de Sergipe |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFS instname:Universidade Federal de Sergipe (UFS) instacron:UFS |
instname_str |
Universidade Federal de Sergipe (UFS) |
instacron_str |
UFS |
institution |
UFS |
reponame_str |
Repositório Institucional da UFS |
collection |
Repositório Institucional da UFS |
bitstream.url.fl_str_mv |
https://ri.ufs.br/jspui/bitstream/riufs/6133/1/CRISTIANE_OLIVEIRA_VALENTE.pdf https://ri.ufs.br/jspui/bitstream/riufs/6133/2/CRISTIANE_OLIVEIRA_VALENTE.pdf.txt https://ri.ufs.br/jspui/bitstream/riufs/6133/3/CRISTIANE_OLIVEIRA_VALENTE.pdf.jpg |
bitstream.checksum.fl_str_mv |
8f7c5518726f5fba6c97e030be0ae0f3 46fc442194eaeb62459cfd80c751c508 70b7a72e46a522caed7664a5bf09fb58 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS) |
repository.mail.fl_str_mv |
repositorio@academico.ufs.br |
_version_ |
1802110716407185408 |